DLA MIL-DTL-43243 D-2002 SEPARATOR PARACHUTE REMOVABLE CONNECTOR LINK [Use In Lieu Of DLA MIL-S-0043243 B]《脱卸式降落伞接头连杆分离器(代替使用 DLA MIL-S-0043243 B)》.pdf
《DLA MIL-DTL-43243 D-2002 SEPARATOR PARACHUTE REMOVABLE CONNECTOR LINK [Use In Lieu Of DLA MIL-S-0043243 B]《脱卸式降落伞接头连杆分离器(代替使用 DLA MIL-S-0043243 B)》.pdf》由会员分享,可在线阅读,更多相关《DLA MIL-DTL-43243 D-2002 SEPARATOR PARACHUTE REMOVABLE CONNECTOR LINK [Use In Lieu Of DLA MIL-S-0043243 B]《脱卸式降落伞接头连杆分离器(代替使用 DLA MIL-S-0043243 B)》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Beneficial comments (recommendations, additions, deletions) and any pertinent data that may be of use in improving this document should be addressed to: Defense Supply Center Richmond, ATTN: DSCR-VBD, 8000 Jefferson Davis Highway, Richmond, VA 23297-5610, by using the Standardization Document Improv
2、ement Proposal (DD Form 1426) appearing at the end of this document or by letter. AMSC N/A FSC 1670 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. INCH-POUND MIL-DTL-43243D 30 May 2002 SUPERSEDING MIL-S-43243C 30 December 1975 DETAIL SPECIFICATION SEPARATOR, PARACH
3、UTE REMOVABLE CONNECTOR LINK This specification is approved for use by all departments and agencies of the Department of Defense. 1. SCOPE 1.1 Scope. This specification covers one type and size of parachute removable connector link separator. 2. APPLICABLE DOCUMENTS 2.1 General. The documents listed
4、 in this section are specified in sections 3 and 4 of this specification. This section does not include documents cited in other sections of this specification or recommended for additional information or as examples. While every effort has been made to ensure the completeness of this list, document
5、 users are cautioned that they must meet all specified requirements of the documents cited in sections 3 and 4 of this specification, whether or not they are listed. 2.2 Government documents. 2.2.1 Specifications and standards. The following specifications and standards form a part of this document
6、to the extent specified herein. Unless otherwise specified, the issues of these documents are those listed in the issue of the Department of Defense Index of Specifications and Standards (DoDISS), and the supplement thereto, cited in the solicitation (see 6.2). Provided by IHSNot for ResaleNo reprod
7、uction or networking permitted without license from IHS-,-,-MIL-DTL-43243D 2 STANDARDS DEPARTMENT OF DEFENSE MIL-STD-129 - Standard Practice for Military Marking. MIL-STD-1916 - DoD Preferred Methods for Acceptance of Product. (Unless otherwise indicated, copies of the above specifications and stand
8、ards are available from the Standardization Documents Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094. Electronic copies of military and federal standards and specifications may be obtained from http:/astimage.daps.dla.mil/quicksearch/.) 2.2.2 Other government publications.
9、The following other government publications form a part of this document to the extent specified herein. Unless otherwise specified, the issues are those cited in the solicitation (see 6.2). DEFENSE FEDERAL ACQUISITION REGULATION SUPPLEMENT (DFARS) DFARS Subpart 209.3 - First Article Testing and App
10、roval. (Application for copies should be addressed to Superintendent of Documents, P.O. Box 371954, Pittsburgh, PA 15250-7954. Electronic copies may be obtained from http:/www.acq.osd.mil/dp/dars/dfars.html.) DRAWINGS 11-1-176 - Separator, Parachute Removable Connector Link; Assembly and Details. 11
11、-1-240 - Spring, Helical, Extension. (Copies of drawings required by suppliers in connection with a specific procurement function should be obtained from the procuring activity or as directed by the contracting officer.) 2.3 Order of precedence. In the event of a conflict between the text of this sp
12、ecification and the references cited herein, the text of this specification takes precedence. Nothing in this specification, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 First article. When specified (see 6.2), the supplier sh
13、all furnish a sample of the separator to be procured under this specification for first article inspection and approval (see 4.2). 3.2 Materials and construction. The materials, construction, and supplementary processes involved in the fabrication of the separator assembly shall conform to the requi
14、rements specified or shown on drawings 11-1-176 and 11-1-240. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-43243D 3 3.3 Workmanship. The parachute removable connector link separator, including all components and assemblies, shall be fabric
15、ated and finished in a thoroughly workman-like manner. Particular attention shall be given to the following: a. All areas shall be free of rust or corrosion, dirt, oil, grease or other foreign matter and tool marks or breaks through plating to metal. b. Free from metal slivers. c. All welding, silve
16、r soldering, and brazing shall be smooth, clean, free of flux, pits, slag, spatter, or porosity, and shall be continuous, adherent, and not burnt through. The joints shall be thoroughly fused. d. Rivets shall be fully peened with heads in full contact with riveted members. The rivets shall be firmly
17、 set and completely fill the hole. Rivet heads shall be full, neatly made, and concentric with rivet holes. Holes for rivets shall be accurately punched or drilled and free of any obstruction. 4. VERIFICATION 4.1 Classification of inspection. The inspection requirements specified herein are classifi
18、ed as follows: a. First article inspection (see 4.2). b. Conformance inspection (see 4.3). 4.2 First article inspection. When a first article inspection is required (see 6.2), the number of units to be provided for inspection shall be specified (see 6.2). Units provided for first article inspection
19、shall be examined for the defects in table I as well as the examinations of paragraph 4.3.1, 4.3.2, and 4.3.3. The presence of any major defect or two or more minor defects listed in table I or any dimension not within specified requirements shall be cause for rejection of the first article. TABLE I
20、. Classification of defects. Classification Examine Defect Major Minor Any area of rust or corrosion 101 Any area with no finish, tool marks, or breaks through plating to metal 201 Finish, protective Dirt, oil, grease, or other foreign matter 202 Any sharp edges, burrs, or metal slivers 102 Any comp
21、onent missing or damaged 103 Any steel component not assembled or joined as specified 104 Design construction and workmanship Felt pad not securely cemented to base 203 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-43243D 4 TABLE I. Classif
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAMILDTL43243D2002SEPARATORPARACHUTEREMOVABLECONNECTORLINKUSEINLIEUOFDLAMILS0043243B 脱卸 降落伞 接头 连杆 分离器

链接地址:http://www.mydoc123.com/p-690772.html