DIN ISO 12789-2-2013 Reference radiation fields - Simulated workplace neutron fields - Part 2 Calibration fundamentals related to the basic quantities (ISO 12789-2 2008)《参考辐射区域 模拟工.pdf
《DIN ISO 12789-2-2013 Reference radiation fields - Simulated workplace neutron fields - Part 2 Calibration fundamentals related to the basic quantities (ISO 12789-2 2008)《参考辐射区域 模拟工.pdf》由会员分享,可在线阅读,更多相关《DIN ISO 12789-2-2013 Reference radiation fields - Simulated workplace neutron fields - Part 2 Calibration fundamentals related to the basic quantities (ISO 12789-2 2008)《参考辐射区域 模拟工.pdf(19页珍藏版)》请在麦多课文档分享上搜索。
1、January 2013 Translation by DIN-Sprachendienst.English price group 11No part of this translation may be reproduced without prior permission ofDIN Deutsches Institut fr Normung e. V., Berlin. Beuth Verlag GmbH, 10772 Berlin, Germany,has the exclusive right of sale for German Standards (DIN-Normen).IC
2、S 17.240!$LW“1934152www.din.deDDIN ISO 12789-2Reference radiation fields Simulated workplace neutron fields Part 2: Calibration fundamentals related to the basic quantities(ISO 12789-2:2008),English translation of DIN ISO 12789-2:2013-01Referenzstrahlungsfelder Simulierte Arbeitsplatz-Neutronenfelde
3、r Teil 2: Grundlagen der Kalibrierung mit Bezug auf Grundgren (ISO 12789-2:2008),Englische bersetzung von DIN ISO 12789-2:2013-01Champs de rayonnement de rfrence Champs de neutrons simulant ceux de postes de travail Partie 2: Concepts dtalonnage en relation avec les grandeurs fondamentales(ISO 12789
4、-2:2008),Traduction anglaise de DIN ISO 12789-2:2013-01www.beuth.deDocument comprises pagesIn case of doubt, the German-language original shall be considered authoritative.1912.12 DIN ISO 12789-2:2013-01 A comma is used as the decimal marker. Contents Page National foreword .3 National Annex NA (inf
5、ormative) Bibliography 3 Introduction .4 1 Scope 5 2 Terms and definitions .5 3 List of symbols .8 4 Properties of simulated workplace neutron field facilities .9 5 Characterization of simulated workplace neutron fields 9 6 Uncertainties . 13 Annex A (normative) Conversion coefficients 16 Bibliograp
6、hy . 18 2 Tables Table A.1 . 16 DIN ISO 12789-2:2013-01 National foreword This standard has been prepared by Technical Committee ISO/TC 85 “Nuclear energy”, Subcommittee SC 2 “Radiation protection” (Secretariat: AFNOR, France). The responsible German body involved in its preparation was the Normenau
7、sschuss Radiologie (Radiology Standards Committee), Working Committee NA 080-00-01 AA Dosimetrie, in collaboration with the Deutsche Rntgengesellschaft (German Radiological Society), the Deutsche Gesellschaft fr Nuklearmedizin e. V. (DGN) (German Society of Nuclear Medicine), the Deutsche Gesellscha
8、ft fr Medizinische Physik e. V. (DGMP) (German Society for Medical Physics) and the Deutsche Gesellschaft fr Radioonkologie e. V. (DEGRO) (German Society for Radio Oncology). The text of ISO 12789-2:2008 “Reference radiation fields Simulated workplace neutron fields Part 2: Calibration fundamentals
9、related to the basic quantities” has been adopted in this standard without any modification. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. DIN shall not be held responsible for identifying any or all such patent rights. DIN ISO
10、12789 consists of the following parts, under the general title Reference radiation fields Simulated workplace neutron fields: Part 1: Characteristics and methods of production Part 2: Calibration fundamentals related to the basic quantities National Annex NA (informative) Bibliography DIN 6802-1:199
11、1-11, Neutron dosimetry Part 1: Special terms and definitions DIN 6814-2:2000-07, Terms in the field of radiological technique Part 2: Radiation physics DIN 6814-3:2001-01, Terms and definitions in the field of radiological technique Part 3: Dose quantities and units 3 Introduction Neutron fields co
12、mmonly encountered in radiation workplaces are, in most cases, quite different from routinely used calibration fields produced using standard radionuclide sources in low-scatter calibration facilities. The dose equivalent response of personal neutron dosemeters and neutron area survey meters depends
13、 upon the energy distributions of the neutron fields in which they are used, and, in the case of personal dosemeters in particular, the angle of incidence of the neutrons. Calibrations of such devices in reference neutron fields as described in ISO 8529 (all parts) do not thus provide appropriate ca
14、libration factors in most cases. For this reason, several laboratories have developed simulated workplace neutron fields that are intended to simulate the characteristics of particular types of fields in which it is necessary to make personal dosemeter and area survey instrument measurements. These
15、provide facilities in which the performance of these devices in workplace fields can be investigate, and that, in some circumstances, can act as calibration facilities. Because workplace neutron fields depend upon the physical structure of each workplace, this part of ISO 12789 has been written to s
16、pecify the methods of producing and characterizing simulated workplace neutron fields rather than standardizing reference fields as is the philosophy in the companion standard, ISO 8529 (all parts). This part of ISO 12789 is closely related to ISO 12789-1, which describes the facilities and methods
17、currently used to produce simulated workplace neutron radiation fields. These fields have been constructed specifically to moderate source neutrons and include neutrons scattered from the surrounding structure and equipment for the simulation of workplace environments. This part of ISO 12789 describ
18、es the methods used to determine conventional values of the operational quantities characterizing the realistic workplace neutron fields. The operational quantities used in this part of ISO 12789 are ambient dose equivalent, H*(10), and personal dose equivalent, Hp(10). For reference radiation field
19、s, it is recommended to determine their conventional values from the neutron fluence or fluence rate as a function of neutron energy and, for the case of Hp(10), the direction using the conversion coefficients listed in Annex A. In some cases, the use of conversion coefficients is not feasible for d
20、etermining Hp(10), necessitating its direct calculation. At present, no simple methods exist to provide traceability of the operational quantities from a national standards institute to the simulated workplace neutron fields. The process of determining operational quantities from fluence described i
21、n this part of ISO 12789 introduces additional uncertainty. values of the operational quantities and gives new information regarding the uncertainty associated with the inference of energy distributions of neutron fluence using accepted unfolding techniques. The uncertainties in determining Hp(10) u
22、sing information from the direction distribution of the neutron fluence can be large but, at present, the quantification of the uncertainty from this source is not addressed. Reference radiation fields Simulated workplace neutron fields Part 2: Calibration fundamentals related to the basic quantitie
23、s 4 This part of ISO 12789 incorporates accepted methods for determining the uncertaintyN1)associated with the DIN ISO 12789-2:2013-01 N1) National footnote: This standard uses the term “uncertainty in measurement” 8 (Messunsicherheit) even if the quantity to be determined is obtained by way of calc
24、ulation. 1 Scope This part of ISO 12789 describes the characterization of simulated workplace neutron fields produced by methods described in ISO 12789-1. It specifies the procedures used for establishing the calibration conditions of radiation protection devices in neutron fields produced by these
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DINISO1278922013REFERENCERADIATIONFIELDSSIMULATEDWORKPLACENEUTRONFIELDSPART2CALIBRATIONFUNDAMENTALSRELATEDTOTHEBASICQUANTITIESISO1278922008

链接地址:http://www.mydoc123.com/p-683994.html