DIN 5034-1-2011 Daylight in interiors - Part 1 General requirements《室内日光照明 第1部分 一般要求》.pdf
《DIN 5034-1-2011 Daylight in interiors - Part 1 General requirements《室内日光照明 第1部分 一般要求》.pdf》由会员分享,可在线阅读,更多相关《DIN 5034-1-2011 Daylight in interiors - Part 1 General requirements《室内日光照明 第1部分 一般要求》.pdf(17页珍藏版)》请在麦多课文档分享上搜索。
1、July 2011DEUTSCHE NORM Normenausschuss Lichttechnik (FNL) im DINDIN-SprachendienstEnglish price group 11No part of this translation may be reproduced without prior permission ofDIN Deutsches Institut fr Normung e. V., Berlin. Beuth Verlag GmbH, 10772 Berlin, Germany,has the exclusive right of sale f
2、or German Standards (DIN-Normen).ICS 91.160.10!$tWr“1815279www.din.deDDIN 5034-1Daylight in interiors Part 1: General requirementsEnglish translation of DIN 5034-1:2011-07Tageslicht in Innenrumen Teil 1: Allgemeine AnforderungenEnglische bersetzung von DIN 5034-1:2011-07Lumire du jour lintrieur Part
3、ie 1: Exigences gnralesTraduction anglaise de DIN 5034-1:2011-07SupersedesDIN 5034-1:1999-10www.beuth.deDocument comprises 17 pages08.12 DIN 5034-1:2011-07 2 A comma is used as the decimal marker. Contents Page Foreword 3 1 Scope 4 2 Normative references 4 3 Terms and definitions .5 4 Requirements f
4、or daylight openings .8 4.1 General 8 4.2 View out 8 4.2.1 General 8 4.2.2 Windows in habitable rooms 8 4.2.3 Windows in work rooms .8 4.2.4 Windows in other rooms 10 4.3 Daylighting 11 4.3.1 Brightness . 11 4.3.2 Fulfilment of visual tasks . 11 4.3.3 Energy demand for lighting . 12 4.3.4 Restrictin
5、g glare 12 4.4 Exposure to sunlight 12 4.5 Shadings 12 4.6 Protection from short-wave radiation . 13 5 Design considerations . 13 5.1 Rooms with windows . 13 5.2 Rooms with rooflights 13 5.3 Consideration of shape and size of the building and of interior rooms . 14 5.4 Consideration of obstructions
6、14 5.5 Consideration of room utilization . 14 5.6 Design of interiors 14 Annex A (informative) Overview of daylighting requirements and recommendations made in this standard . 15 Bibliography . 17 DIN 5034-1:2011-07 3 Foreword This document has been prepared by Working Committee NA 058-00-06 AA Inne
7、nraumbeleuchtung mit Tageslicht of the Normenausschuss Lichttechnik (Lighting Technology Standards Committee). DIN 5034 Daylight in interiors comprises: Part 1: General requirements Part 2. Principles Part 3: Calculation Part 4: Simplified determination of minimum window sizes for dwellings Part 5:
8、Measurement Part 6: Simplified determination of suitable dimensions for rooflights Attention is drawn to the possibility that some elements of this document may be the subject of patent rights. DIN shall not be held responsible for identifying any or all such patent rights. Amendments This standard
9、differs from DIN 5034-1:1999-10 as follows: a) this document has been editorially revised; b) the normative references have been updated (e.g. to reflect the withdrawal of DIN 5035-1 and DIN 5035-2 and their replacement/partial replacement by DIN EN 12464-1 and DIN EN 12665). Previous editions DIN 5
10、034: 1935-11, 1959-11, 1969-12 DIN 5034-1: 1983-02, 1999-10 DIN 5034-1:2011-07 4 1 Scope Daylight in interiors can be considered under different aspects: its psychological effects, including the subjective impression of brightness and the visual view to the outside (view out); visual conditions, for
11、 instance the illuminance needed to fulfil a visual task, or the limitation of glare; its biological effects, for instance its impact on health, well-being and performance; thermal comfort, e.g. the limitation of harmful exposure to radiation and heat; energy efficiency, e.g. reducing energy consump
12、tion in buildings through the use of daylight. This standard specifies minimum requirements for achieving, by means of natural light, an adequate subjective impression of brightness indoors, and for providing a sufficient view out. In addition, requirements for the duration of sunshine exposure with
13、in habitable and occupied rooms are given. At present there is not enough knowledge of the biological effects of daylight to deal with them in a standard. This standard gives information on how to use daylighting to provide adequate lighting within interiors, and how to limit glare and heat irradiat
14、ion. Partial characteristics regarding the energy efficiency of lighting with daylight can be calculated on the basis of this standard. The standard applies to all occupied rooms, including work rooms within the meaning of the German Lnder building regulations and/or the Arbeitsstttenverordung (Germ
15、an Workplaces Ordinance). The standard also applies to all workplaces other than habitable rooms (such as workplaces in warehouses), except where daylighting is contrary to the nature and role of the work at hand. 2 Normative references The following referenced documents are indispensable for the ap
16、plication of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. DIN 5031-3, Optical radiation physics and illuminating engineering; quantities, symbols and units of illuminatin
17、g engineering DIN 5034-3, Daylight in interiors Part 3: Calculation DIN 5034-4, Daylight in interiors Part 4: Simplified determination of minimum window sizes for dwellings DIN 5034-6, Daylight in interiors Part 6: Simplified determination of suitable dimensions for rooflights DIN 5035-3, Artificial
18、 lighting Part 3: Lighting of health care premises DIN 5035-7, Artificial lighting Part 7: Lighting of interiors with visual displays work stations DIN 5036-4, Radiometric and photometric properties of materials; classification DIN EN 410, Glass in building Determination of luminous and solar charac
19、teristics of glazing DIN EN 12464-1, Light and lighting Lighting of workplaces Part 1: Indoor work places DIN EN 12665, Light and lighting Basic terms and criteria for specifying lighting requirements DIN V 18599-4, Energy efficiency of buildings Calculation of the net, final and primary energy dema
20、nd for heating, cooling, ventilation, domestic hot water and lighting Part 4: Net and final energy demand for lighting DIN 5034-1:2011-07 5 3 Terms and definitions For the purposes of this standard, the terms and definitions in DIN EN 12665, and the following, apply. 3.1 occupied room room which is
21、intended or is suitable for human occupation for more than a brief duration NOTE The term “occupied room” includes habitable rooms, work rooms and the other rooms defined below. 3.2 habitable room occupied room in a dwelling such as a living room, bedroom, study, childrens playroom, or an occupied r
22、oom in a facility whose purpose is comparable to living NOTE 1 Rooms which function as living areas, such as common rooms or lounges in senior citizens homes, boarding schools or child care centres are also considered as habitable rooms. This does not include, however, rooms which are primarily used
23、 for sleeping, such as accommodations in a hotel, etc. NOTE 2 Kitchens, halls and other areas which are not occupied for a long period are not considered as habitable rooms even if they are equipped with spaces for eating, resting or working. 3.3 work room room which is permanently equipped with wor
24、kplaces within a building 3.4 other room occupied room which is not a habitable room or work room NOTE For the purposes of this standard, “other rooms” may be classrooms, or patients rooms in outpatient and inpatient medical care faciltities, etc. 3.5 illuminance (at a point on a surface) E quotient
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DIN503412011DAYLIGHTININTERIORSPART1GENERALREQUIREMENTS 室内 日光 照明 部分 一般 要求 PDF

链接地址:http://www.mydoc123.com/p-658234.html