CSA C22 2 NO 107 3-2014 Uninterruptible power systems (Third Edition).pdf
《CSA C22 2 NO 107 3-2014 Uninterruptible power systems (Third Edition).pdf》由会员分享,可在线阅读,更多相关《CSA C22 2 NO 107 3-2014 Uninterruptible power systems (Third Edition).pdf(136页珍藏版)》请在麦多课文档分享上搜索。
1、C22.2 No. 107.3-14Uninterruptible power systemsLegal Notice for StandardsCanadian Standards Association (operating as “CSA Group”) develops standards through a consensus standards development process approved by the Standards Council of Canada. This process brings together volunteers representing va
2、ried viewpoints and interests to achieve consensus and develop a standard. Although CSA Group administers the process and establishes rules to promote fairness in achieving consensus, it does not independently test, evaluate, or verify the content of standards.Disclaimer and exclusion of liabilityTh
3、is document is provided without any representations, warranties, or conditions of any kind, express or implied, including, without limitation, implied warranties or conditions concerning this documents fitness for a particular purpose or use, its merchantability, or its non-infringement of any third
4、 partys intellectual property rights. CSA Group does not warrant the accuracy, completeness, or currency of any of the information published in this document. CSA Group makes no representations or warranties regarding this documents compliance with any applicable statute, rule, or regulation. IN NO
5、EVENT SHALL CSA GROUP, ITS VOLUNTEERS, MEMBERS, SUBSIDIARIES, OR AFFILIATED COMPANIES, OR THEIR EMPLOYEES, DIRECTORS, OR OFFICERS, BE LIABLE FOR ANY DIRECT, INDIRECT, OR INCIDENTAL DAMAGES, INJURY, LOSS, COSTS, OR EXPENSES, HOWSOEVER CAUSED, INCLUDING BUT NOT LIMITED TO SPECIAL OR CONSEQUENTIAL DAMA
6、GES, LOST REVENUE, BUSINESS INTERRUPTION, LOST OR DAMAGED DATA, OR ANY OTHER COMMERCIAL OR ECONOMIC LOSS, WHETHER BASED IN CONTRACT, TORT (INCLUDING NEGLIGENCE), OR ANY OTHER THEORY OF LIABILITY, ARISING OUT OF OR RESULTING FROM ACCESS TO OR POSSESSION OR USE OF THIS DOCUMENT, EVEN IF CSA GROUP HAS
7、BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES, INJURY, LOSS, COSTS, OR EXPENSES.In publishing and making this document available, CSA Group is not undertaking to render professional or other services for or on behalf of any person or entity or to perform any duty owed by any person or entity to an
8、other person or entity. The information in this document is directed to those who have the appropriate degree of experience to use and apply its contents, and CSA Group accepts no responsibility whatsoever arising in any way from any and all use of or reliance on the information contained in this do
9、cument. CSA Group is a private not-for-profit company that publishes voluntary standards and related documents. CSA Group has no power, nor does it undertake, to enforce compliance with the contents of the standards or other documents it publishes. Intellectual property rights and ownershipAs betwee
10、n CSA Group and the users of this document (whether it be in printed or electronic form), CSA Group is the owner, or the authorized licensee, of all works contained herein that are protected by copyright, all trade-marks (except as otherwise noted to the contrary), and all inventions and trade secre
11、ts that may be contained in this document, whether or not such inventions and trade secrets are protected by patents and applications for patents. Without limitation, the unauthorized use, modification, copying, or disclosure of this document may violate laws that protect CSA Groups and/or others in
12、tellectual property and may give rise to a right in CSA Group and/or others to seek legal redress for such use, modification, copying, or disclosure. To the extent permitted by licence or by law, CSA Group reserves all intellectual property rights in this document.Patent rightsAttention is drawn to
13、the possibility that some of the elements of this standard may be the subject of patent rights. CSA Group shall not be held responsible for identifying any or all such patent rights. Users of this standard are expressly advised that determination of the validity of any such patent rights is entirely
14、 their own responsibility.Authorized use of this documentThis document is being provided by CSA Group for informational and non-commercial use only. The user of this document is authorized to do only the following:If this document is in electronic form:sLOADTHISDOCUMENTONTOACOMPUTERFORTHESOLEPURPOSE
15、OFREVIEWINGITsSEARCHANDBROWSETHISDOCUMENTANDsPRINTTHISDOCUMENTIFITISIN0$ relevant clause, table, and/or figure number; wording ofthe proposed change; and rationale for the change.To purchase CSA Group Standards and related publications, visit CSA Groups Online Store atshop.csa.ca or call toll-free 1
16、-800-463-6727 or 416-747-4044.Copyright 2014 Underwriters Laboratories Inc.ULs Standards for Safety are copyrighted by UL. Neither a printed nor electronic copy of a Standardshould be altered in any way. All of ULs Standards and all copyrights, ownerships, and rights regardingthose Standards shall r
17、emain the sole and exclusive property of UL.This ANSI/UL Standard for Safety consists of the Fifth Edition. The most recent designation of ANSI/UL1778 as an American National Standard (ANSI) occurred on June 10, 2014. ANSI approval for astandard does not include the Cover Page, Transmittal Pages, Ti
18、tle Page (front and back), or thePreface.Comments or proposals for revisions on any part of the Standard may be submitted to UL at any time.Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative StandardsDevelopment System (CSDS) at http:/.To purchase UL Standards, visit C
19、omm 2000 at http:/m- call toll-free 1-888-853-3503.CONTENTSPreface .61 General 81.1 Scope .81.2 Definitions 101.3 General requirements 131.4 General conditions for tests .141.5 Components 141.6 Power interface .161.7 Markings and instructions 172 Protection from hazards 262.1 Protection from electri
20、c shock and energy hazards 262.6 Provisions for earthing and bonding .272.7 Overcurrent and earth fault protection in primary circuits .282.8 Safety interlocks 302.9 Electrical insulation 323 Wiring, connections, and supply .323.1 General 323.4 Disconnection from the mains supply 333.5 Interconnecti
21、on of equipment .344 Physical requirements 344.1 Stability 344.3 Design and construction 344.5 Thermal requirements 364.6 Openings in enclosures 375 Electrical requirements and simulated abnormal conditions .375.101 Short-circuit fault current withstand rating markings 375.2 Electric strength .385.3
22、 Abnormal operating and fault conditions 386 Connection to telecommunication networks .427 Connection to cable distribution systems 42AnnexesAnnex AAA (normative) Additional component requirementsAAA.1 Capacitor surge current test 44AAA.2 Oil-filled capacitor fault test .44AAA.3 Electrolytic capacit
23、or fault test 44AAA.4 Control devices .44AAA.4.2 Overload (control devices) .45AAA.4.3 Endurance (control devices) 46AAA.5 Static transfer switches 46AAA.5.1 General 46AAA.5.2 Isolating means .47AAA.5.3 Tests 47AAA.6 Transfer switches .47AAA.7 Load transfer .47JUNE 13, 2014 CSA C22.2 NO. 107.3-14 UL
24、 1778 3AAA.8 Bus bars .48AAA.8.13 Bus bar tests 51Annex BBB (informative) Examples of NORMAL LOAD conditionsBBB.1 General 52Annex CCC (informative) Safety symbols and their meaningsAnnex DDD (normative) Harmonic distortion testAnnex EEE (normative) Earthing and bonding (see 2.6.)EEE.1 General requir
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- CSAC222NO10732014UNINTERRUPTIBLEPOWERSYSTEMSTHIRDEDITIONPDF

链接地址:http://www.mydoc123.com/p-621189.html