1、BRITISH STANDARD BS ISO 3507:1999 Laboratory glassware Pyknometers ICS 17.060; 71.040.20BSISO3507:1999 This British Standard, having been prepared under the directionof the Sector Board forMaterials and Chemicals, waspublished under the authorityof the Standards Committee and comes into effect on 15
2、August1999 BSI 04-2000 ISBN 0 580 32971 2 National foreword This British Standard reproduces verbatim ISO3507:1999and implements it as the UK national standard. It supersedes BS733-1:1983which is withdrawn. The UK participation in its preparation was entrusted by Technical CommitteeLBI/36, Laborator
3、y glassware and related apparatus, to Subcommittee LBI/36/4, Density measuring instruments, which has the responsibility to: aid enquirers to understand the text; present to the responsible international/European committee any enquiries on the interpretation, or proposals for change, and keep the UK
4、 interests informed; monitor related international and European developments and promulgate them in the UK. A list of organizations represented on this committee can be obtained on request to its secretary. Cross-references The British Standards which implement international or European publications
5、 referred to in this document may be found in the BSI Standards Catalogue under the section entitled “International Standards Correspondence Index”, or by using the “Find” facility of the BSI Standards Electronic Catalogue. A British Standard does not purport to include all the necessary provisions
6、of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pages i and ii, theISO title page, pag
7、es ii to iv, pages 1 to 11 and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on the inside front cover. Amendments issued since publication Amd. No. Date CommentsBSISO3507:1999 BSI 04-2000 i C
8、ontents Page National foreword Inside front cover Foreword iii Text of ISO 3507 1ii blankBSISO3507:1999 ii BSI 04-2000 Contents Page Foreword iii 1 Scope 1 2 Normative references 1 3 Basis of adjustment 1 3.1 Unit of volume 1 3.2 Reference temperature 1 4 Types and series of sizes 1 5 Capacities of
9、pyknometers 1 5.1 Actual capacity 1 5.2 Nominal capacity 1 6 Difference between actual capacity, nominal capacity and accuracy 2 7 Construction 2 7.1 Material 2 7.2 Mass 2 7.3 Dimensions 2 7.4 Shape 2 7.5 Necks 3 7.6 Stoppers and thermometer 3 8 Graduation lines 3 8.1 General 3 8.2 Type 1 4 8.2.1 Po
10、sition of scale 4 8.2.2 Length of graduation lines 4 8.2.3 Figuring of graduation lines 4 8.3 Type 2 4 8.4 Type 4 4 9 Marking 4 10 Visibility of graduation lines, figures and markings 4 Annex A (informative) Device for adjusting the liquid level in a Reischauer-type pyknometer 11 Figure 1 Type 1 (Li
11、pkin) pyknometer tube 7 Figure 2 Type 2 (Sprengel) pyknometer tube 8 Figure 3 Type 3 (Gay-Lussac) pyknometer flask 9 Figure 4 Type 4 (Reischauer) pyknometer flask 9 Figure 5 Type 5 (Hubbard) pyknometer flask 10 Figure 6 Pyknometer flask with ground-in thermometer and capillary side tube 10 Figure A.
12、1 Draw-off needle 11 Figure A.2 Filling needle 11 Table 1 Types and sizes of pyknometers 1 Table 2 Dimensional requirements for pyknometer tubes types 1 and 2 5 Table 3 Dimensional requirements for pyknometer flasks types 4 and 5 5 Table 4 Dimensional requirements for pyknometer flasks types 3 and 6
13、 6BSISO3507:1999 BSI 04-2000 iii Foreword ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO member bodies). The work of preparing International Standards is normally carried out through ISO technical committees. Each member body inte
14、rested in a subject for which a technical committee has been established has the right to be represented on that committee. International organizations, governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnica
15、l Commission (IEC) on all matters of electrotechnical standardization. International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 3. International Standard ISO3507was prepared by Technical Committee ISO/TC 48, Laboratory glassware and related apparatus, Su
16、bcommittee SC 4, Density measuring instruments. This second edition cancels and replaces the first edition (ISO 3507:1976) by incorporating the following changes: a) the title has been modified; b) Gay-Lussac pyknometers of 1 ml, 2 ml, 5 ml and 100 ml have been added; c) Reischauer pyknometers of 10
17、 ml and 100 ml have been added; d) a Hubbard pyknometer of 50 ml has been added; e) pyknometers with ground-in thermometer and capillary side tube have been added.iv blankBSISO3507:1999 BSI 04-2000 1 1 Scope This International Standard specifies requirements for a series of pyknometers for general l
18、aboratory use for the determination of the densities of liquids. Specialized pyknometers for use with particular products, or otherwise not in common use, are excluded. Sufficient details to define such pyknometers should be included in International Standards which specify or describe their use. A
19、device suitable for adjustment of the liquid level in the neck of the Reischauer pyknometer is shown in Annex A. 2 Normative references The following normative documents contain provisions which, through reference in this text, constitute provisions of this International Standard. For dated referenc
20、es, subsequent amendments to, or revisions of, any of these publications do not apply. However, parties to agreements based on this International Standard are encouraged to investigate the possibility of applying the most recent editions of the normative documents indicated below. For undated refere
21、nces, the latest edition of the normative document referred to applies. Members of ISO and IEC maintain registers of currently valid International Standards. ISO 383, Laboratory glassware Interchangeable conical ground joints. ISO 384:1978, Laboratory glassware Principles of design and construction
22、of volumetric glassware. ISO 386, Liquid-in-glass laboratory thermometers Principles of design, constructionand use. ISO 719, Glass Hydrolytic resistance of glass grains at98 C Method of test and classification. ISO 3585, Borosilicate glass 3.3 Properties. 3 Basis of adjustment 3.1 Unit of volume Th
23、e unit of volume shall be the millilitre (ml), which is equivalent to the cubic centimetre (cm 3 ). NOTEThe term millilitre (ml) is commonly used as a special name for the cubic centimetre (cm 3 ), in accordance with a decision of the Twelfth Confrence Gnrale des Poids et Mesures. The term millilitr
24、e is acceptable, in general, for references in International Standards to capacities of volumetric glassware and it is used in this International Standard. 3.2 Reference temperature If the actual capacity is marked on a pyknometer, the verification temperature at which this actual capacity is determ
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSISO35071999LABORATORYGLASSWAREPYKNOMETERS 试验室 玻璃器皿 比重瓶 PDF

链接地址:http://www.mydoc123.com/p-587088.html