《BS 6070-7-1981 Methods of sampling and test for sodium carbonate for industrial use - Determination of copper content《工业用碳酸钠取样及试验方法 第7部分 铜含量测定》.pdf》由会员分享,可在线阅读,更多相关《BS 6070-7-1981 Methods of sampling and test for sodium carbonate for industrial use - Determination of copper content《工业用碳酸钠取样及试验方法 第7部分 铜含量测定》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS 6070-7: 1981 Methods of Sampling and test for sodium carbonate for industrial use Part 7: Determination of copper content NOTEIt is recommended that this Part be read in conjunction with the information in the “Generalintroduction” published separately as BS6070-0. UDC 661.833.62
2、2:546.33264:543.42.062:546.56BS6070-7:1981 This British Standard, having been prepared under the directionof the Chemicals Standards Committee, was published under the authority ofthe Executive Board and comesinto effect on 27February1981 BSI 12-1999 The following BSI reference relates to the work o
3、n this standard: Committee reference CIC/22 ISBN 0 580 12006 6 A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity fr
4、om legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pages i and ii, pages1 and 2, an inside back cover and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the amendm
5、ent table on the inside front cover. Amendments issued since publication Amd. No. Date of issue CommentsBS6070-7:1981 BSI 12-1999 i Contents Page 1 Scope 1 2 Reference 1 3 Principle 1 4 Reagents 1 5 Apparatus 1 6 Procedure 1 7 Expression of results 2 Table 1 Volumes of standard copper solution 1 Pub
6、lication referred to Inside back coverii blankBS6070-7:1981 BSI 12-1999 1 1 Scope This Part of BS6070 describes a method for the determination of the copper content of sodium carbonate for industrial use. The method is applicable to products having copper contents, expressed as Cu, in the range0.5mg
7、/kg to10mg/kg. There is no International Standard corresponding to this Part of BS6070. 2 Reference The title of the publication referred to in this standard is given on the inside back cover. 3 Principle The copper present is reduced with ascorbic acid and a violet coloured complex is formed by add
8、ition of 2,2-biquinolyl. This complex is extracted with amyl alcohol and its colour measured spectrophotometrically. 4 Reagents The following reagents are required and shall be of recognized analytical quality. Water complying with the requirements of BS3978 shall be used throughout. 4.1 Sodium sulp
9、hate, anhydrous. 4.2 Hydrochloric acid solution, approximately1.18g/ml, approximately36% m/m solution or approximately11N. 4.3 Amyl alcohol 4.4 (+)-Tartaric acid, 500g/l solution. 4.5 Sodium hydroxide, 200g/l solution. 4.6 L-Ascorbic acid, 100g/l solution, freshly prepared. 4.7 2,2Biquinolyl, 0.5g/l
10、 solution. Dissolve0.25g of2,2biquinolyl in the amyl alcohol (4.3) and dilute with more of the amyl alcohol to500ml. 4.8 Bromine water, saturated solution. 4.9 Copper, standard solution corresponding to0.1g of copper per litre. Dissolve0.3928g of copper (II) sulphate pentahydrate (CuSO 4 .5H 2 O) in
11、 water in a1000ml one-mark volumetric flask, add25ml of approximately6N sulphuric acid solution, dilute to the mark and mix. 1 ml of this standard solution contains 0.100mg ofCu. 4.10 Copper, standard solution corresponding to0.01g of copper per litre. Dilute10.0ml of the standard copper solution (4
12、.9) to the mark in a100ml one-mark volumetric flask and mix. 1 ml of this standard solution contains104g of Cu. 4.11 Narrow range indicator papers, covering the range pH5.5 to pH7.0. 4.12 Methyl orange indicator, 0.5g/l aqueous solution. 5 Apparatus Ordinary laboratory apparatus and the following ar
13、e required. 5.1 Spectrophotometer, or 5.2 Photoelectric absorptiometer, fitted with filters providing maximum transmission at a wavelength of about545nm. 5.3 Optical cells, 4cm optical path length. 6 Procedure 6.1 Test portion. Weigh, to the nearest0.1g, about10g of the sample. 6.2 Blank test. Carry
14、 out a blank test at the same time as the determination, following the same procedure and using the same quantities of reagents as specified in6.3.2 but omitting the test portion. 6.3 Preparation of the calibration graph 6.3.1 Preparation of standard matching solutions Into each of a series of six50
15、0ml stoppered separating funnels introduce the volumes of the standard copper solution (4.10) shown inTable 1. Table 1 Volumes of standard copper solution Standard copper solution (4.10) Corresponding mass of copper (Cu) ml g 0 a 0 2.0 20 4.0 40 6.0 60 8.0 80 10.0 100 a Compensation solutionBS6070-7
16、:1981 2 BSI 12-1999 6.3.2 Colour development. Treat the contents of each funnel (6.3.1) as follows. Dilute with water to approximately400ml, then add2ml of the tartaric acid solution (4.4). Adjust the pH of the solution to about6.0by addition of the sodium hydroxide solution (4.5) using the narrow r
17、ange indicator paper (4.11) externally. Add2ml of the ascorbic acid solution(4.6), shake so as to mix thoroughly and allow to stand for5min. Add10ml of the 2,2-biquinolyl solution (4.7) and shake well for about2min. Extract the copper complex with two20ml portions of the amyl alcohol (4.3), and tran
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS607071981METHODSOFSAMPLINGANDTESTFORSODIUMCARBONATEFORINDUSTRIALUSEDETERMINATIONOFCOPPERCONTENT 工业

链接地址:http://www.mydoc123.com/p-545684.html