BS 1722-10-2006 Fences - Specification for anti-intruder fences in chain link and welded mesh《栅栏 链节和焊接筛网的防盗栅栏用规范》.pdf
《BS 1722-10-2006 Fences - Specification for anti-intruder fences in chain link and welded mesh《栅栏 链节和焊接筛网的防盗栅栏用规范》.pdf》由会员分享,可在线阅读,更多相关《BS 1722-10-2006 Fences - Specification for anti-intruder fences in chain link and welded mesh《栅栏 链节和焊接筛网的防盗栅栏用规范》.pdf(42页珍藏版)》请在麦多课文档分享上搜索。
1、BS 1722-10:2006Fences Part 10: Specification for anti-intruder fences in chain link and welded meshICS 91.090NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBRITISH STANDARDPublishing and copyright informationThe BSI copyright notice displayed in this document indicates when th
2、e document was last issued. BSI 2006ISBN 0 580 49507 8The following BSI references relate to the work on this standard:Committee reference B/201Draft for comment 06/30139509 DCPublication historyFirst pubished October 1963Second edition February 1972Third edition July 1990Fourth edition May 1999Fift
3、h (present) edition November 2006Amendments issued since publicationAmd. no. Date Text affectedBS 1722-10:2006 BSI 2006 iBS 1722-10:2006ContentsForeword ii1 Scope 12 Normative references 13 Wire for chain link fences 34 Concrete components for chain link fences 35 Steel posts for chain link fences 6
4、6 Fittings for chain link fences 97 Concrete surrounding bases of posts and struts for chain link fences 118 Installation of chain link fences 119 Materials for welded mesh fences 1510 Installation of welded mesh fences 1611 Construction of gates 1812 Installation of gates 2113 Statement of conformi
5、ty 21AnnexesAnnex A (normative) Concrete components 23Annex B (normative) Steel components 25Annex C (informative) Specifying a wire mesh fence 26Bibliography 34List of figuresFigure C.1 Typical fences conforming to BS 1722-10 29Figure C.2 Intermediate post options 30Figure C.3 Joining welded mesh b
6、etween posts 31Figure C.4 Typical double gate detail (internal elevation) 32Figure C.5 Typical gate arrangement with straining posts 33List of tablesTable 1 Diameters of wires in chain link Dimensions in millimetres 4Table 2 Recommended dimensions for steel posts and struts 8Table 3 Recommended dime
7、nsions for steel gate posts 8Table B.1 Recommended steel grades 26Summary of pagesThis document comprises a front cover, an inside front cover, pages i to iv, pages 1 to 34, an inside back cover and a back cover.BS 1722-10:2006ii BSI 2006ForewordPublishing informationThis part of BS 1722 was publish
8、ed by BSI and came into effect on 30 November 2006. It was prepared by Technical Committee B/201, Fences and gates. A list of organizations represented on this committee can be obtained on request to its secretary.SupersessionThis part of BS 1722 supersedes BS 1722-10:1999, which is withdrawn.Relati
9、onship with other publicationsBS 1722 is published in parts as follows: Part 1: Specification for chain link fences; Part 2: Specification for strained wire and wire mesh netting fences; Part 4: Specification for cleft chestnut pale fences; Part 5: Specification for close-boarded and wooden palisade
10、 fences; Part 7: Specification for wooden post and rail fences; Part 8: Specification for mild steel (low carbon steel) continuous bar fences and hurdles; Part 9: Specification for mild steel (low carbon steel) fences with round or square verticals and flat horizontals; Part 10: Specification for an
11、ti-intruder fences in chain link and welded mesh; Part 11: Specification for prefabricated wood panel fences; Part 12: Specification for steel palisade fences; Part 13: Chain link fences for tennis court surrounds1); Part 14: Specification for open mesh steel panel fences; Part 16: Specification for
12、 organic powder coatings to be used as a plastics finish to components and mesh; Part 17: Specification for electric security fences Design, installation and maintenance; Part 18: Specification for steel mesh site perimeter temporary fencing systems.2)Information about this documentIt should be note
13、d that no attempt has been made to standardize fences or gates of a purely decorative nature, or to suit special requirements; nor to specify requirements for “patent” proprietary fencing systems. It is recommended, however, that such fences or gates should be designed in accordance with the relevan
14、t clauses of this part of BS 1722.1)Obsolescent.2)Part 18 is in development and will be published as a Draft for Development (DD). BSI 2006 iiiBS 1722-10:2006This standard aims to establish minimum requirements for material and workmanship of the more common types of fence in order to ensure satisfa
15、ctory service for the purchaser, and to assist manufacturers and installing contractors by eliminating unnecessary minor variations in the demands of purchasers. It specifies requirements for the components that make up a fence and the way in which the fence should be constructed.Choosing a fence is
16、 affected by factors such as intended purpose, desired service life, aesthetic considerations and availability of components. The specifier can match a suitable choice of fence to its intended purpose by reference to Table 1 and Table 2 and also inform those installing the fence of the basic charact
17、eristics required.Premature failure of the fence can be avoided by taking care not to damage protective treatments during installation.This standard specifies the requirements for anti-intruder wire mesh fences. It may be used as a specification for work to be carried out by a specialist fencing con
18、tractor or, if such a contractor is not available, by local labour under strict supervision, with component parts supplied by firms approved by the purchaser.The specification given in this standard is suitable for use in industrial estates, airfields, oil and gas installations, etc. where an enhanc
19、ed level of security over fences conforming to BS 1722-1 is required. Other types of enhanced security fences are specified in BS 1722-12 security palisade (SP) fences and in the relevant clauses of BS 1722-14.It should be noted that throughout this part of BS 1722 fence post spacings are given in t
20、erms of centre-to-centre distances.Ground conditions may indicate that a variation in the length of a post or strut, or the depth to which it should be set, is desirable. The post and strut setting depths specified in this standard are intended for use in normal ground conditions but if special cond
21、itions exist that warrant a change in the specification, e.g. the ground is softer or firmer than usual, such a change should be agreed with the specifier. This also applies to other similar changes.Use of this documentIt has been assumed in the drafting of this part of BS 1722 that the execution of
22、 its provision is entrusted to appropriately qualified and experienced people. Before installation commences the Lead Installer should hold a current FISS/CSCS registration card skilled level (blue card) or equivalent and all other operatives should hold the basic fence operative card (green card) o
23、r equivalent.At the time of publication of this British Standard the registration cards are validated by the Joint Fencing Industry Skills Scheme (FISS) and Construction Scheme Skills Certification Scheme (CSCS). FISS/CSCS maintains a national register of fence installers and operatives. There might
24、 be other schemes available.Presentational conventionsThe provisions of this standard are presented in roman (i.e. upright) type. Its requirements are expressed in sentences in which the principal auxiliary verb is “shall”.BS 1722-10:2006iv BSI 2006Commentary, explanation and general informative mat
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS1722102006FENCESSPECIFICATIONFORANTIINTRUDERFENCESINCHAINLINKANDWELDEDMESH 栅栏 焊接 筛网 防盗 规范 PDF

链接地址:http://www.mydoc123.com/p-542834.html