ASTM ISO ASTM51608-2015 Standard Practice for Dosimetry in an X-Ray (Bremsstrahlung) Facility for Radiation Processing at Energies between 50 keV and 7 5 MeV《能量范围在50 keV和7 5 MeV之间的.pdf
《ASTM ISO ASTM51608-2015 Standard Practice for Dosimetry in an X-Ray (Bremsstrahlung) Facility for Radiation Processing at Energies between 50 keV and 7 5 MeV《能量范围在50 keV和7 5 MeV之间的.pdf》由会员分享,可在线阅读,更多相关《ASTM ISO ASTM51608-2015 Standard Practice for Dosimetry in an X-Ray (Bremsstrahlung) Facility for Radiation Processing at Energies between 50 keV and 7 5 MeV《能量范围在50 keV和7 5 MeV之间的.pdf(16页珍藏版)》请在麦多课文档分享上搜索。
1、ISO/ASTM 51608:2015(E)An American National StandardStandard Practice forDosimetry in an X-Ray (Bremsstrahlung) Facility forRadiation Processing at Energies between 50 keV and 7.5MeV1This standard is issued under the fixed designation ISO/ASTM 51608; the number immediately following the designation i
2、ndicates theyear of original adoption or, in the case of revision, the year of last revision.1. Scope1.1 This practice outlines the dosimetric procedures to befollowed during installation qualification, operationalqualification, performance qualification and routine processingat an X-ray (bremsstrah
3、lung) irradiator. Other proceduresrelated to operational qualification, performance qualificationand routine processing that may influence absorbed dose in theproduct are also discussed.NOTE 1Dosimetry is only one component of a total quality assuranceprogram for adherence to good manufacturing prac
4、tices used in radiationprocessing applications.NOTE 2ISO/ASTM Practices 51649, 51818 and 51702 describedosimetric procedures for electron beam and gamma facilities for radia-tion processing.1.2 For radiation sterilization of health care products, seeISO 11137-1, Sterilization of health care products
5、 Radiation Part 1: Requirements for development, validation androutine control of a sterilization process for medical devices.Inthose areas covered by ISO 11137-1, that standard takesprecedence.1.3 For irradiation of food, see ISO 14470, Food irradiation Requirements for development, validation and
6、routine con-trol of the process of irradiation using ionizing radiation forthe treatment of food. In those areas covered by ISO 14470,that standard takes precedence.1.4 This document is one of a set of standards that providesrecommendations for properly implementing and utilizingdosimetry in radiati
7、on processing. It is intended to be read inconjunction with ISO/ASTM Practice 52628, “Practice forDosimetry in Radiation Processing”.1.5 In contrast to monoenergetic gamma radiation, theX-ray energy spectrum extends from low values (about 35keV) up to the maximum energy of the electrons incident ont
8、he X-ray target (see Section 5 and Annex A1).1.6 Information about effective or regulatory dose limits andenergy limits for X-ray applications is not within the scope ofthis practice.1.7 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is there
9、sponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced documents2.1 ASTM Standards:2E170 Terminology Relating to Radiation Measurements andDosimetryE2232 Guide for Selection
10、 and Use of Mathematical Meth-ods for Calculating Absorbed Dose in Radiation Process-ing ApplicationsE2303 Guide for Absorbed-Dose Mapping in RadiationProcessing Facilities2.2 ISO/ASTM Standards:251261 Practice for Calibration of Routine Dosimetry Sys-tems for Radiation Processing51539 Guide for Use
11、 of Radiation-Sensitive Indicators51649 Practice for Dosimetry in an Electron Beam Facilityfor Radiation Processing at Energies Between 300 keVand 25 MeV51702 Practice for Dosimetry in a Gamma Facility forRadiation Processing51707 Guide for Estimating Uncertainties in Dosimetry forRadiation Processi
12、ng51818 Practice for Dosimetry in an Electron Beam Facilityfor Radiation Processing at Energies Between 80and 300keV52628 Practice for Dosimetry in Radiation Processing1This practice is under the jurisdiction of ASTM Committee E61 on RadiationProcessing and is the direct responsibility of Subcommitt
13、ee E61.03 on DosimetryApplication, and is also under the jurisdiction of ISO/TC 85/WG 3.Current edition approved Sept. 8, 2014. Published February 2015. Originallypublished as ASTM E 160894. Last previous ASTM edition E 160800. ASTM E160894 was adopted by ISO in 1998 with the intermediate designatio
14、n ISO15567:1998(E). The present International Standard ISO/ASTM 51608:2015(E) is amajor revision of the last previous edition ISO/ASTM 51608:2005(E), whichreplaced ISO/ASTM 51608:2002(E).2For referenced ASTM or ISO/ASTM standards, visit the ASTM website,www.astm.org, or contact ASTM Customer Service
15、 at serviceastm.org. ForAnnual Book of ASTM Standards volume information, refer to the standardsDocument Summary page on the ASTM website. ISO/ASTM International 2015 All rights reserved152701 Guide for Performance Characterization of Dosim-eters and Dosimetry Systems for use in Radiation Process-in
16、g2.3 ISO Standards:3ISO 11137-1 Sterilization of health care products Radia-tion Part 1: Requirements for development, validationand routine control of a sterilization process for medicaldevicesISO 14470 Food irradiation Requirements for thedevelopment, validation and routine control of the processo
17、f irradiation using ionizing radiation for the treatment offood2.4 International Commission on Radiation Units and Mea-surements (ICRU) Reports:4ICRU Report 14 Radiation Dosimetry: X Rays and GammaRays with Maximum Photon Energies Between 0.6 and 50MeVICRU Report 34 Dosimetry of Pulsed RadiationICRU
18、 Report 35 Radiation Dosimetry: Electron Beams withEnergies Between 1 and 50 MeVICRU Report 37 Stopping Powers for Electrons and Posi-tronsICRU Report 80 Dosimetry Systems for Use in RadiationProcessingICRU Report 85a Fundamental Quantities and Units forIonizing Radiation2.5 Joint Committee for Guid
19、es in Metrology (JCGM)Report:JCGM 100:2008, GUM 1995, with minor corrections,Evaluation of measurement dataGuide to the expressionof uncertainty in measurement53. Terminology3.1 Definitions:3.1.1 absorbed dose (D)quantity of ionizing radiationenergy imparted per unit mass of a specified material. Th
20、e SIunit of absorbed dose is the gray (Gy), where 1 gray isequivalent to the absorption of 1 joule per kilogram of thespecified material (1 Gy = 1 J/kg). The mathematical relation-ship is the quotient of d by dm, where d is the meanincremental energy imparted by ionizing radiation to matter ofincrem
21、ental mass dm (see ICRU Report 85a).D 5 d/dm (1)3.1.2 beam lengthdimension of the irradiation zone alongthe direction of product movement, at a specified distance fromthe accelerator window.3.1.2.1 DiscussionBeam length is perpendicular to beamwidth and to the electron beam axis. In case of product
22、that isstationary during irradiation, beam length and beam widthmay be interchangeable.3.1.3 beam widthdimension of the irradiation zone per-pendicular to the direction of product movement, at a specifieddistance from the accelerator window.3.1.3.1 DiscussionFor graphic illustration, see ISO/ASTM Pr
23、actice 51649. This term usually applies to electronirradiation.3.1.4 bremsstrahlungbroad-spectrum electromagnetic ra-diation emitted when an energetic charged particle is influ-enced by a strong electric or magnetic field, such as that in thevicinity of an atomic nucleus.3.1.4.1 DiscussionIn radiati
24、on processing, bremsstrahl-ung photons with sufficient energy to cause ionization aregenerated by the deceleration or deflection of energetic elec-trons in a target material. When an electron passes close to anatomic nucleus, the strong coulomb field causes the electron todeviate from its original m
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 1人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMISOASTM516082015STANDARDPRACTICEFORDOSIMETRYINANXRAYBREMSSTRAHLUNGFACILITYFORRADIATIONPROCESSINGATENERGIESBETWEEN50KEVAND75MEV

链接地址:http://www.mydoc123.com/p-540774.html