ASTM F3023-2018 Standard Test Methods for Evaluating Design and Performance Characteristics of Stationary Upright and Recumbent Exercise Bicycles and Upper and Total Body Ergometer.pdf
《ASTM F3023-2018 Standard Test Methods for Evaluating Design and Performance Characteristics of Stationary Upright and Recumbent Exercise Bicycles and Upper and Total Body Ergometer.pdf》由会员分享,可在线阅读,更多相关《ASTM F3023-2018 Standard Test Methods for Evaluating Design and Performance Characteristics of Stationary Upright and Recumbent Exercise Bicycles and Upper and Total Body Ergometer.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F3023 18Standard Test Methods forEvaluating Design and Performance Characteristics ofStationary Upright and Recumbent Exercise Bicycles andUpper and Total Body Ergometers1This standard is issued under the fixed designation F3023; the number immediately following the designation indicate
2、s the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.INTRODUCTIONThe goal of these test methods is to provide r
3、eliable and repeatable methods for the evaluation ofstationary upright and recumbent exercise bicycles and ergometers.The equipment user must recognize, however, that a standard alone will not necessarily preventinjuries. Like other physical activities, exercise involving stationary this equipment i
4、nvolves the riskof injury, particularly if the equipment is used improperly or is not properly maintained. In addition,users with physical limitations should seek medical advice and instruction from the fitness facilityprior to using this equipment. Certain physical conditions or limitations may pre
5、clude some personsfrom using this equipment as intended by the manufacturer, and using this equipment may increase therisk of injury.1. Scope1.1 These test methods specify procedures and equipmentused for testing and evaluating stationary exercise upright andrecumbent bicycles and ergometers for com
6、pliance to Specifi-cation F1250. Both design and operational parameters will beevaluated. Where possible and applicable, accepted test meth-ods from other recognized bodies will be used and referenced.In the case of a conflict between this document and Specifica-tion F1250, Specification F1250 takes
7、 precedence.1.2 RequirementsStationary exercise bicycles and ergom-eters are to be tested for the parameters specified in Specifi-cation F2276 and Test Methods F2571 and the followingparameters unique to this equipment:1.2.1 Seat post construction and loading,1.2.2 Handlebar construction and loading
8、,1.2.3 Pedal construction and loading,1.2.4 Crank arm and enclosure entrapment,1.2.5 Seat back support loading,1.2.6 Stability,1.2.7 Direct Drive Exercise Bicycle Pedal Endurance,1.2.8 Warnings, and1.2.9 Documentation.1.3 This test method2contains additional requirements toaddress the accessibility
9、of the equipment for persons withdisabilities.1.4 UnitsThe values stated in SI units are to be regardedas standard. The values given in parentheses are mathematicalconversions to inch-pound units that are provided for informa-tion only and are not considered standard.1.5 This standard does not purpo
10、rt to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety, health, and environmental practices and deter-mine the applicability of regulatory limitations prior to use.1.6 This international standard
11、 was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade (TBT) Committee.2. Refer
12、enced Documents2.1 ASTM Standards:31These test methods are under the jurisdiction of ASTM Committee F08 onSports Equipment, Playing Surfaces, and Facilities and are the direct responsibilityof Subcommittee F08.30 on Fitness Products.Current edition approved June 1, 2018. Published August 2018. Origi
13、nallyapproved in 2013. Last previous edition approved in 2013 as F3023 13. DOI:10.1520/F3023-18.2This work was funded, in part, by the Rehabilitation Engineering ResearchCenter on RecTech through the National Institute on Disability, Independent Living,and Rehabilitation Research grant #90RE5009-01-
14、00.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Bo
15、x C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendations issued by t
16、he World Trade Organization Technical Barriers to Trade (TBT) Committee.1F1250 Specification for Stationary Upright and RecumbentExercise Bicycles and Upper and Total Body ErgometersF1749 Specification for Fitness Equipment and Fitness Fa-cility Safety Signage and LabelsF2276 Specification for Fitne
17、ss EquipmentF2277 Test Methods for Evaluating Design and PerformanceCharacteristics of Selectorized Strength EquipmentF2571 Test Methods for Evaluating Design and PerformanceCharacteristics of Fitness EquipmentF3021 Specification for Universal Design of Fitness Equip-ment for Inclusive Use by Person
18、s with Functional Limi-tations and ImpairmentsF3022 Test Method for Evaluating the Universal Design ofFitness Equipment for Inclusive Use by Persons withFunctional Limitations and Impairments3. Terminology3.1 DefinitionsFor definitions applicable to this standard,see Specifications F1250 and F3021.4
19、. Significance and Use4.1 The purpose of these test methods is to provide reliableand repeatable test methods for the evaluation of stationaryexercise bicycles and ergometers assembled and maintainedaccording to the manufacturers specifications. Use of thesetest methods in conjunction with Specifica
20、tions F1250 andF3021 is intended to ensure appropriate performance andreliability of said equipment and reduce the risk of seriousinjury from design deficiencies.5. Sample Preparations5.1 Assemble and adjust the machine on a horizontalsurface according to the manufacturers instructions. For ma-chine
21、s that are fully assembled, verify according to themanufacturers instructions that all components are functioningand that they have been adjusted and aligned properly. Unlessotherwise stated, the machine must pass the following testswithout adjustment from this initial condition.Apply power to,if re
22、quired, or use the machine and verify that the unitfunctions properly.5.2 The individual test methods will describe any variationsor modifications to the test sample that are required.5.3 Unless noted, the machine shall function as intended bythe manufacturer after the completion of each test.6. Tes
23、t Methods and Procedures6.1 In addition to the tests specified in Test Methods F2571,stationary exercise bicycles and ergometers shall be evaluatedwith the following test methods and procedures. These testmethods align with the design and construction requirementsspecified in Specification F1250 (Se
24、ction 5).6.2 Seat PostThe purpose of this test is to evaluate theconstruction and retention of the seat post.6.2.1 Apparatus and Set UpThe sample shall be set up asdescribed in Section 5.6.2.2 CalibrationVerify that the measurement device isproperly calibrated and has a resolution of 1 mm (0.04 in.)
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF30232018STANDARDTESTMETHODSFOREVALUATINGDESIGNANDPERFORMANCECHARACTERISTICSOFSTATIONARYUPRIGHTANDRECUMBENTEXERCISEBICYCLESANDUPPERANDTOTALBODYERGOMETERPDF

链接地址:http://www.mydoc123.com/p-539918.html