ASTM F3022-2016 Standard Test Method for Evaluating the Universal Design of Fitness Equipment for Inclusive Use by Persons with Functional Limitations and Impairments《评估由带有功能限制和障碍的.pdf
《ASTM F3022-2016 Standard Test Method for Evaluating the Universal Design of Fitness Equipment for Inclusive Use by Persons with Functional Limitations and Impairments《评估由带有功能限制和障碍的.pdf》由会员分享,可在线阅读,更多相关《ASTM F3022-2016 Standard Test Method for Evaluating the Universal Design of Fitness Equipment for Inclusive Use by Persons with Functional Limitations and Impairments《评估由带有功能限制和障碍的.pdf(41页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F3022 16Standard Test Method forEvaluating the Universal Design of Fitness Equipment forInclusive Use by Persons with Functional Limitations andImpairments1This standard is issued under the fixed designation F3022; the number immediately following the designation indicates the year ofor
2、iginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.INTRODUCTIONThe goal of this test method is to provide reliable and repea
3、table methods for the evaluation ofuniversally designed fitness equipment.The equipment user must recognize, however, that the standard alone will not necessarily preventinjuries. Like other physical activities, exercise involving fitness equipment involves the risk of injury,particularly if the equ
4、ipment is used improperly or not properly maintained. In addition, users withphysical limitations should seek medical advice and instruction from the fitness facility prior to usingthis equipment. Certain physical conditions or limitations may preclude some persons from using theequipment properly a
5、nd without increasing the risk of serious injury.1. Scope1.1 This test method2specifies procedures and equipmentused for testing and evaluating the accessibility of fitnessequipment for compliance to Specification F3021 design pa-rameters. Where possible and applicable, accepted test meth-ods from o
6、ther recognized bodies will be used and referenced.In case of a conflict between this document and SpecificationF3021, Specification F3021 takes precedence.1.2 This test method is to be used in conjunction withSpecification F3021.1.3 This standard is to be used as additional requirements toaddress t
7、he accessibility of the equipment for persons withdisabilities.NOTE 1Additional test methods applicable to specific pieces ofequipment, such as treadmills, bicycles, ellipticals, and strength equip-ment are currently under development.1.4 The values stated in SI units are to be regarded as thestanda
8、rd. The values given in parentheses are for informationonly.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-b
9、ility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:3E177 Practice for Use of the Terms Precision and Bias inASTM Test MethodsE691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test MethodF2571 Test Methods for Evaluating Design an
10、d PerformanceCharacteristics of Fitness EquipmentF3021 Specification for Universal Design of Fitness Equip-ment for Inclusive Use by Persons with Functional Limi-tations and Impairments3. Terminology3.1 DefinitionsFor definitions applicable to this standardsee Specification F3021.4. Sample Preparati
11、on4.1 Assemble and adjust the fitness equipment apparatus ona horizontal surface according to the manufacturers instruc-tions. Verify that assembled units are done so according to the1This test method is under the jurisdiction of ASTM Committee F08 on SportsEquipment, Playing Surfaces, and Facilitie
12、s and is the direct responsibility ofSubcommittee F08.30 on Fitness Products.Current edition approved Oct. 1, 2016. Published January 2017. Originallyapproved in 2013. Last previous edition approved in 2015 as F3022 15. DOI:10.1520/F3022-16.2This work was funded, in part, by the Rehabilitation Engin
13、eering ResearchCenter on RecTech through the National Institute on Disability, Independent Living,and Rehabilitation Research grant #90RE5009-01-00.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandar
14、ds volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles o
15、n standardization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.1manufacturers instructions. Unless otherwise stated, the fit-ness equipment appara
16、tus must pass the following tests withoutadjustment from this initial condition.4.2 Any equipment with a removable/movable seat shall beset up with the seat in the non-moved position.4.3 The individual test methods will describe any variationsor modifications that are required to the test sample.5.
17、Test Methods and Procedures5.1 General Requirements:5.1.1 Access and Set Up:5.1.1.1 Access, Egress, and TransferThis test is a visualinspection of the sample to ensure that all access paths to thepiece of equipment, set in the start position, are not obstructedby the frame or other structural parts
18、of the equipment.Apparatus and Set UpThe sample shall be set up asdescribed in Section 4.CalibrationNo calibration required. Visual inspectiononly.ProcedureInspect all access paths to verify that the pathis clear of any obstruction by the frame or other structuralparts.Pass/Fail CriteriaThe access p
19、ath shall conform to theclear space requirements of subsection 5.1.1.1 of SpecificationF3021.Precision and BiasNo information is presented abouteither the precision or bias of test 5.1.1.1 for evaluating accesssince the test result is non-quantitative.NOTE 2Performance tests to get on/off the equipm
20、ent from theperspective of a broad range of people with disabilities, including peopleusing wheelchairs or those who have functional limitations, sensorydeficits, cognitive impairments, visual, or hearing impairments, or acombination thereof, is suggested. One possible method would be to usetesters
21、with disabilities.5.1.1.2 Maximum Approach PositionsThis test is a visualinspection of the sample to ensure that access paths to the pieceof equipment, set in the start position, are available from asmany positions as possible (that is, front, rear, left, and right).Apparatus and Set UpThe sample sh
22、all be set up asdescribed in Section 4.CalibrationNo calibration required. Visual inspectiononly.ProcedureInspect access paths from the front, rear, left,and right of the equipment to verify that the path is clear of anyobstruction by the frame or other structural parts from as manypoints of access
23、as possible.Pass/Fail CriteriaEquipment must be accessible andshall avoid left/right bias as specified in the requirements ofsubsection 5.1.1.2 of Specification F3021. There is no pass/failcriteria.Precision and BiasEquipment must be accessible andshall avoid left/right bias as specified in the requ
24、irements ofsubsection 5.1.1.2 of Specification F3021. There is no pass/failcriteria.5.1.1.3 Step-On HeightThis test is a dimensional inspec-tion of the sample to ensure the dimensional compliance of thestep-on height.Apparatus and Set UpThe sample shall be set up asdescribed in Section 4 in the neut
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF30222016STANDARDTESTMETHODFOREVALUATINGTHEUNIVERSALDESIGNOFFITNESSEQUIPMENTFORINCLUSIVEUSEBYPERSONSWITHFUNCTIONALLIMITATIONSANDIMPAIRMENTS

链接地址:http://www.mydoc123.com/p-539915.html