ASTM F2487-2013(2017) Standard Practice for Infiltration and Exfiltration Acceptance Testing of Installed Corrugated High Density Polyethylene and Polypropylene Pipelines《已安装高密度聚乙烯.pdf
《ASTM F2487-2013(2017) Standard Practice for Infiltration and Exfiltration Acceptance Testing of Installed Corrugated High Density Polyethylene and Polypropylene Pipelines《已安装高密度聚乙烯.pdf》由会员分享,可在线阅读,更多相关《ASTM F2487-2013(2017) Standard Practice for Infiltration and Exfiltration Acceptance Testing of Installed Corrugated High Density Polyethylene and Polypropylene Pipelines《已安装高密度聚乙烯.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F2487 13 (Reapproved 2017) An American National StandardStandard Practice forInfiltration and Exfiltration Acceptance Testing of InstalledCorrugated High Density Polyethylene and PolypropylenePipelines1,2This standard is issued under the fixed designation F2487; the number immediately f
2、ollowing the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been ap
3、proved for use by agencies of the U.S. Department of Defense.1. Scope*1.1 This practice covers procedures for testing installednon-perforated, gasketed corrugated high-density polyethylene(HDPE) and corrugated polypropylene (PP) pipelines usingeither water infiltration or exfiltration acceptance lim
4、its todemonstrate the integrity via the level of leakage of theinstalled materials, construction procedures and installationqualityvia the level of leakage. Pipe to be tested under thispractice shall include corrugated HDPE and PP drainage pipemeeting the requirements of AASHTO M 252, AASHTO M294 an
5、d Specifications F2306/F2306M, F2736, F2762, F2763,F2764/F2764M, and F2947/F2947M.NOTE 1The performance criteria specified in this standard may beused for other plastic pipe products. The engineer, however, must assess ifthe testing procedures are adequate for the particular material andinstallation
6、 being considered.NOTE 2The user of this practice is advised that test criteria presentedin this practice are similar to those in general use. Pipe, 600-mm (24-in.)diameter or larger, may be accepted by visual inspection when testing forinfiltration.1.2 The values stated in SI units are to be regard
7、ed as thestandard. The values in parentheses are mathematical conver-sions to inch-pounds, which are provided for informationalpurposes only and are not considered standard.1.3 This test method shall be performed on lines after allconnections and service laterals have been plugged and bracedadequate
8、ly to withstand the test pressures. The time betweencompletion of the backfill operations and testing shall bespecified by the approving authority.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this sta
9、ndard to establish appro-priate safety, health, and environmental practices and deter-mine the applicability of regulatory limitations prior to use.1.5 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision
10、on Principles for theDevelopment of International Standards, Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:3D3212 Specification for Joints for Drain and Sewer PlasticPipes Using Flexible Elastom
11、eric SealsF412 Terminology Relating to Plastic Piping SystemsF2306/F2306M Specification for 12 to 60 in. 300 to 1500mm Annular Corrugated Profile-Wall Polyethylene (PE)Pipe and Fittings for Gravity-Flow Storm Sewer andSubsurface Drainage ApplicationsF2736 Specification for 6 to 30 in. (152 To 762 mm
12、)Polypropylene (PP) Corrugated Single Wall Pipe AndDouble Wall PipeF2762 Specification for 12 to 30 in. (300 to 750 mm)Annular Corrugated Profile-Wall Polyethylene (PE) Pipeand Fittings for Sanitary Sewer Applications (Withdrawn2016)4F2763 Specification for 12 to 60 in. 300 to 1500 mm Dualand Triple
13、 Profile-Wall Polyethylene (PE) Pipe and Fit-tings for Sanitary Sewer ApplicationsF2764/F2764M Specification for 6 to 60 in. 150 to 1500mm Polypropylene (PP) Corrugated Double and TripleWall Pipe and Fittings for Non-Pressure Sanitary SewerApplicationsF2947/F2947M Specification for 150 to 1500 mm 6
14、to 60in. Annular Corrugated Profile-Wall Polyethylene (PE)1This practice is under the jurisdiction of ASTM Committee F17 on PlasticPiping Systems and is the direct responsibility of Subcommittee F17.20 on Joining.Current edition approved Nov. 1, 2017. Published November 2017. Originallyapproved in 2
15、006. Last previous edition approved in 2012 as F248706(2012). DOI:10.1520/F2487-13.2Available from American Association of State Highway and TransportationOfficials (AASHTO), 444 N. Capitol St., NW, Suite 249, Washington, DC 20001,http:/www.transportation.org.3For referenced ASTM standards, visit th
16、e ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.4The last approved version of this historical standard is referenced onwww.astm.org.*A Summary of Cha
17、nges section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the De
18、cision on Principles for theDevelopment of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.1Pipe and Fittings for Sanitary Sewer Applications2.2 AASHTO Standards2M 252 Standard Specification for Corrugated Polyeth
19、yleneDrainage Pipe 75 to 250-mm (3 to 10-inch) DiameterM 294 Standard Specification for Corrugated PolyethyleneDrainage Pipe 300 to 1500-mm (12 to 60-inch) Diameter3. Terminology3.1 DefinitionsFor definitions of terms relating to plasticpipe, see Terminology F412.4. Summary of Practice4.1 Determine
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF248720132017STANDARDPRACTICEFORINFILTRATIONANDEXFILTRATIONACCEPTANCETESTINGOFINSTALLEDCORRUGATEDHIGHDENSITYPOLYETHYLENEANDPOLYPROPYLENEPIPELINES

链接地址:http://www.mydoc123.com/p-538832.html