ASTM F2487-2013 Standard Practice for Infiltration and Exfiltration Acceptance Testing of Installed Corrugated High Density Polyethylene and Polypropylene Pipelines《已安装高密度聚乙烯和聚丙烯波纹.pdf
《ASTM F2487-2013 Standard Practice for Infiltration and Exfiltration Acceptance Testing of Installed Corrugated High Density Polyethylene and Polypropylene Pipelines《已安装高密度聚乙烯和聚丙烯波纹.pdf》由会员分享,可在线阅读,更多相关《ASTM F2487-2013 Standard Practice for Infiltration and Exfiltration Acceptance Testing of Installed Corrugated High Density Polyethylene and Polypropylene Pipelines《已安装高密度聚乙烯和聚丙烯波纹.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F2487 06 (Reapproved 2012)F2487 13 An American National StandardStandard Practice forInfiltration and Exfiltration Acceptance Testing of InstalledCorrugated High Density Polyethylene and PolypropylenePipelines1,2This standard is issued under the fixed designation F2487; the number immed
2、iately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has
3、 been approved for use by agencies of the U.S. Department of Defense.1. Scope Scope*1.1 This practice covers procedures for testing installed non-perforated, gasketed corrugated high-density polyethylene (HDPE)and corrugated polypropylene (PP) pipelines using either water infiltration or exfiltratio
4、n acceptance limits to demonstrate theintegrity via the level of leakage of the installed materials, construction procedures and installation qualityvia the level of leakage.Pipe to be tested under this practice shall include corrugated HDPE and PP drainage pipe meeting the requirements of AASHTOM 2
5、52, AASHTO M 294 and SpecificationSpecifications F2306/F2306M., F2736, F2762, F2763, F2764, and F2947.NOTE 1The performance criteria specified in this standard may be used for other plastic pipe products. The engineer, however, must assess if thetesting procedures are adequate for the particular mat
6、erial and installation being considered.NOTE 2The user of this practice is advised that test criteria presented in this practice are similar to those in general use. Pipe, 600-mm (24-in.)diameter or larger, may be accepted by visual inspection when testing for infiltration.1.2 The values stated in S
7、I units are to be regarded as the standard. The values in parentheses are mathematical conversions toinch-pounds, which are provided for informational purposes only and are not considered standard.1.3 This test method shall be performed on lines after all connections and service laterals have been p
8、lugged and bracedadequately to withstand the test pressures. The time between completion of the backfill operations and testing shall be specifiedby the approving authority.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibi
9、lityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use. The testing required under this standard necessitates operating in confined spaces. The user must insurethat all OSHA and local safety codes ar
10、e duly observed.2. Referenced Documents2.1 ASTM Standards:3D3212 Specification for Joints for Drain and Sewer Plastic Pipes Using Flexible Elastomeric SealsF412 Terminology Relating to Plastic Piping SystemsF2306/F2306M Specification for 12 to 60 in. 300 to 1500 mm Annular Corrugated Profile-Wall Po
11、lyethylene (PE) Pipe andFittings for Gravity-Flow Storm Sewer and Subsurface Drainage ApplicationsF2736 Specification for 6 to 30 in. (152 To 762 mm) Polypropylene (PP) Corrugated Single Wall Pipe And Double Wall PipeF2762 Specification for 12 to 30 in. (300 to 750 mm) Annular Corrugated Profile-Wal
12、l Polyethylene (PE) Pipe and Fittings forSanitary Sewer ApplicationsF2763 Specification for 30 to 60 in. 750 to 1500 mm Triple Profile-Wall Polyethylene (PE) Pipe and Fittings for SanitarySewer ApplicationsF2764 Specification for 30 to 60 in. 750 to 1500 mm Polypropylene (PP) Triple Wall Pipe and Fi
13、ttings for Non-PressureSanitary Sewer Applications1 This practice is under the jurisdiction of ASTM Committee F17 on Plastic Piping Systems and is the direct responsibility of Subcommittee F17.20 on Joining.Current edition approved Aug. 1, 2012Nov. 1, 2013. Published October 2012December 2013. Origi
14、nally approved in 2006. Last previous edition approved in 20062012as F2487F248706(2012).06. DOI: 10.1520/F2487-06R12.10.1520/F2487-13.2 Available from American Association of State Highway and Transportation Officials (AASHTO), 444 N. Capitol St., NW, Suite 249, Washington, DC 20001,http:/www.transp
15、ortation.org.3 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.This document is not an ASTM standard and is int
16、ended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the curr
17、ent versionof the standard as published by ASTM is to be considered the official document.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1F2947 Specification for 150 to
18、1500 mm 6 to 60 in. Annular Corrugated Profile-Wall Polyethylene (PE) Pipe and Fittings forSanitary Sewer Applications2.2 AASHTO Standards2M 252 Standard Specification for Corrugated Polyethylene Drainage Pipe 75 to 250-mm (3 to 10-inch) DiameterM 294 Standard Specification for Corrugated Polyethyle
19、ne Drainage Pipe 300 to 1500-mm (12 to 60-inch) Diameter3. Terminology3.1 DefinitionsFor definitions of terms relating to plastic pipe, see Terminology F412.4. Summary of Practice4.1 Determine the groundwater conditions surrounding the section of pipeline to be tested and select the type of test to
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF24872013STANDARDPRACTICEFORINFILTRATIONANDEXFILTRATIONACCEPTANCETESTINGOFINSTALLEDCORRUGATEDHIGHDENSITYPOLYETHYLENEANDPOLYPROPYLENEPIPELINES

链接地址:http://www.mydoc123.com/p-538831.html