ASTM F2357-2004 Standard Test Method for Determining the Abrasion Resistance of Inks and Coatings on Membrane Switches Using the Norman Tool RCA Abrader《使用NORMAN工具 RCA 磨擦器测定薄膜开关上.pdf
《ASTM F2357-2004 Standard Test Method for Determining the Abrasion Resistance of Inks and Coatings on Membrane Switches Using the Norman Tool RCA Abrader《使用NORMAN工具 RCA 磨擦器测定薄膜开关上.pdf》由会员分享,可在线阅读,更多相关《ASTM F2357-2004 Standard Test Method for Determining the Abrasion Resistance of Inks and Coatings on Membrane Switches Using the Norman Tool RCA Abrader《使用NORMAN工具 RCA 磨擦器测定薄膜开关上.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F 2357 04Standard Test Method forDetermining the Abrasion Resistance of Inks and Coatingson Membrane Switches Using the Norman Tool “RCA”Abrader1,2This standard is issued under the fixed designation F 2357; the number immediately following the designation indicates the year oforiginal a
2、doption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method describes the procedure for subjectinginks or coati
3、ngs on membrane switches to an abrasive mediumat a specified force.1.2 Within certain limitations, as described in this docu-ment, this test method is applicable for materials including, butnot limited to: printed or coated polyester, polycarbonate, andsilicone rubber. The samples can be either flat
4、 or contoured.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2
5、. Referenced Documents2.1 ASTM Standards:3F 2112 Terminology for Membrane Switches3. Terminology3.1 Definitions:3.1.1 final breakthroughthe number of cycles until com-plete removal of the first surface ink or coating being tested.3.1.2 membrane switcha momentary switching device inwhich at least one
6、 contact is on, or made of, a flexiblesubstrate.3.1.3 wear limitin testing membrane switches, the numberof cycles until an underlying layer of different color may beseen through the first layer (not applicable for transparentcoatings).4. Significance and Use4.1 Membrane Switch keys are subjected to
7、repeated actua-tions, usually by a human finger. They are also subjected toother conditions (for example, wiping, cleaning, rubbing)during handling, end-use, shipment, or storage that may causeabrasion damage. The result may be a significant removal ofthe coatings, text or decorative inks.4.2 This t
8、est method is applicable to a wide range ofmaterials. The main criterion is that the abrasion processproduces visible wear or breakthrough in the surface beingtested.4.3 The amount of abrasion damage to a surface is depen-dent on numerous variables. This test method provides a wayof comparing relati
9、ve abrasion resistance of inks and coatings.In no way do the results provide a correlation value of thenumber of human finger touches before coating failure. It onlyprovides a means to compare results of tests performed usingthe same equipment, abrasive materials and loading conditions.4.4 The test
10、method can be used for quality control pur-poses, as a research and development tool, to evaluate materialcombinations for a given application, or for the comparison ofmaterials with relatively similar properties.5. Interferences5.1 Inconsistent wear can occur which will compromise theresults. Cauti
11、on is necessary to ensure the mounting methoddoes not deflect the specimen, which may influence the wearcharacteristics.5.2 Contoured surfaces can be tested but results may bemore difficult to duplicate and some equipment is not designedto test non-flat surfaces.5.3 Whenever possible, a smooth surfa
12、ce is preferred. Extracare should be taken when evaluating a non-uniform surface(that is, rough surface), and for the user to recognize potentialvariations between specimens.6. Apparatus6.1 Machine capable of providing cyclic or continuousabrasion to a test specimen under controlled loading condi-ti
13、ons.6.2 Suggested Sources:1This test method is under the jurisdiction of ASTM Committee F01 onElectronics and is the direct responsibility of Subcommittee F01.18 on MembraneSwitches.Current edition approved March 1, 2004. Published April 2004.2The Norman Tool “RCA” Abrader is covered by a patent. In
14、terested parties areinvited to submit information regarding the identification of an alternative(s) to thispatented item to the ASTM International Headquarters. Your comments will receivecareful consideration at a meeting of the responsible technical committee, whichyou may attend.3For referenced AS
15、TM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshoh
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF23572004STANDARDTESTMETHODFORDETERMININGTHEABRASIONRESISTANCEOFINKSANDCOATINGSONMEMBRANESWITCHESUSINGTHENORMANTOOLRCAABRADER

链接地址:http://www.mydoc123.com/p-538492.html