ASTM F2248-2009 Standard Practice for Specifying an Equivalent 3-Second Duration Design Loading for Blast Resistant Glazing Fabricated with Laminated Glass《用夹层玻璃制造的防爆玻璃窗的等效3秒持续时间设计.pdf
《ASTM F2248-2009 Standard Practice for Specifying an Equivalent 3-Second Duration Design Loading for Blast Resistant Glazing Fabricated with Laminated Glass《用夹层玻璃制造的防爆玻璃窗的等效3秒持续时间设计.pdf》由会员分享,可在线阅读,更多相关《ASTM F2248-2009 Standard Practice for Specifying an Equivalent 3-Second Duration Design Loading for Blast Resistant Glazing Fabricated with Laminated Glass《用夹层玻璃制造的防爆玻璃窗的等效3秒持续时间设计.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F2248 09Standard Practice forSpecifying an Equivalent 3-Second Duration Design Loadingfor Blast Resistant Glazing Fabricated with LaminatedGlass1This standard is issued under the fixed designation F2248; the number immediately following the designation indicates the year oforiginal adop
2、tion or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.INTRODUCTIONHistorical records show that fragments from glazing that has failed as t
3、he result of intentional oraccidental explosions present a serious threat of personal injury. Glazing failure also allows blastpressure to enter the interior of buildings thus resulting in additional threat of personal injury andfacility damage. This standard practice provides a means for designers
4、to determine equivalent3-second duration design loadings with which they can size blast resistant glazing comprised oflaminated glass or insulating glass fabricated with laminated glass, or both. Blast resistant glazingsystems of this genre can reduce the number and size of glass fragments in an exp
5、losion as well asreducing greatly or eliminating blast pressure that enters buildings when an explosion occurs.1. Scope1.1 This practice sets forth a method to specify an equiva-lent 3-second design loading suitable to use with PracticeE1300 to select the thickness and type of blast resistant glazin
6、gfabricated with laminated glass to glaze a fenestration. Glassplies used to construct laminated glass are recommended to beeither annealed or heat strengthened glass.1.2 This practice applies to blast resistant glazing fabricatedusing laminated glass only, including single laminated glassand insula
7、ting glass fabricated with laminated glass. As aminimum, insulating glass shall use laminated glass for theinboard (protected side) lite.1.3 This practice assumes that blast resistant glazing shallbe adhered to its supporting frame using structural siliconesealant or adhesive glazing tape. The width
8、 of the structuralsilicone sealant bead shall be at least equal to the larger of10-mm (38-in.) or the thickness designation of the glass towhich it adheres but not larger than two times the thicknessdesignation of the glass to which it adheres. The minimumthickness of the structural silicone bead sh
9、all be 5-mm (316-in.). The width of glazing tape shall be at least equal to twotimes but not more than four times the thickness designation ofthe glass to which it adheres. The width of silicone or glazingtape is referred to as bite and is shown and discussed in GuideC1564.1.4 This practice assumes
10、that the structural silicone bead orglazing tape is applied to both sides of single lite laminatedglass but need only be applied to the inboard side (protectedside) of insulating glass.1.5 This practice assumes the framing members shall re-strict deflections of edges of blast resistant glazing they
11、supportto L/60 under 2.03 the load resistance of the blast resistantglazing for inward loading, where L denotes the length of thesupported edge.1.6 This practice assumes the framing system supporting theblast resistant glazing shall attach mechanically to the struc-tural framing system. The system s
12、hall be designed to ensurethat the glazing fails prior to the framing system that supportsthe glazing and its attachment to the structural framing system.The fasteners that attach the framing system that supports theglazing to the structural framing system shall be designed toresist a uniform load a
13、cting on the blast resistant glazing thathas a magnitude of at least:1.6.1 Two (2.0) times the magnitude of the load resistanceof the blast resistant glazing if the maximum air blast pressureis greater than one half the magnitude of the load resistance ofthe blast resistant glazing, or1.6.2 One (1.0
14、) times the magnitude of the load resistance ofthe blast resistant glazing if the maximum air blast pressure isless than one half the magnitude of the load resistance of theblast resistant glazing.1This practice is under the jurisdiction of ASTM Committee F12 on SecuritySystems and Equipment and is
15、the direct responsibility of Subcommittee F12.10 onSystems Products and Services.Current edition approved Nov. 1, 2009. Published December 2009. Originallyapproved in 2003. Last previous edition approved in 2003 as F2248 03. DOI:10.1520/F2248-09.1Copyright ASTM International, 100 Barr Harbor Drive,
16、PO Box C700, West Conshohocken, PA 19428-2959, United States.1.7 Blast resistant glazing designed using this practicerecommends the use of annealed or heat strengthened glassplies for the laminated glass. Blast testing has shown that useof fully tempered glass plies, when fractured during a blasteve
17、nt, have poorer post blast performance than annealled orheat strengthened glass plies. Laminated glass fabricated withfully tempered glass plies has a tendency to leave the support-ing glazing system frame after fracture whereas laminatedglass fabricated with annealed or heat strengthened glass plie
18、swill remain in the frame and absorb remaining load throughtensile membrane behavior. Use of the annealed or heatstrengthened glass plies will also reduce the amount of loadtransferred into the structure.1.8 The equivalent 3-second design load as determinedherein shall not apply to the design of mon
19、olithic glazing,plastic glazing, or security film applied to existing glazingconfigurations in an attempt to achieve blast resistance.1.9 The values stated in SI units are to be regarded as thestandard. Values given in parentheses are for information only.For conversion of quantities in various syst
20、ems of measure-ments to SI units refer to ANSI IEEE/SI 10.1.10 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bi
21、lity of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C1036 Specification for Flat GlassC1048 Specification for Heat-Treated Flat GlassKind HS,Kind FT Coated and Uncoated GlassC1172 Specification for Laminated Architectural Flat GlassC1422 Specification for Chemicall
22、y Strengthened FlatGlassC1564 Guide for Use of Silicone Sealants for ProtectiveGlazing SystemsE631 Terminology of Building ConstructionsE1300 Practice for Determining Load Resistance of Glassin BuildingsF1642 Test Method for Glazing and Glazing Systems Sub-ject to Airblast Loadings2.2 ANSI Standard:
23、3IEEE/SI 10 Use of the International System of Units (SI):(The Modernized Metric System)23. Terminology3.1 Definitions:3.1.1 blast resistant glazing, nglazing that provides pro-tection against air blast pressure generated by explosions.3.1.2 design load, nmagnitude in kPa (psf) of 3-secondduration u
24、niformly distributed lateral pressure.3.1.3 equivalent TNT charge mass, nmass of TNT placedon the ground in a hemisphere that represents the designexplosive threat.NOTE 1If a different high explosive material comprises the designthreat, tables exist to convert its mass to an equivalent TNT mass. Ref
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF22482009STANDARDPRACTICEFORSPECIFYINGANEQUIVALENT3SECONDDURATIONDESIGNLOADINGFORBLASTRESISTANTGLAZINGFABRICATEDWITHLAMINATEDGLASS

链接地址:http://www.mydoc123.com/p-538201.html