《ASTM F994-1986(2011) Standard Specification for Design and Installation of Overboard Discharge Hull Penetration Connections《向船外排水船身渗透连接件的设计与安装标准规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM F994-1986(2011) Standard Specification for Design and Installation of Overboard Discharge Hull Penetration Connections《向船外排水船身渗透连接件的设计与安装标准规范》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F994 86 (Reapproved 2011)An American National StandardStandard Specification forDesign and Installation of Overboard Discharge HullPenetration Connections1This standard is issued under the fixed designation F994; the number immediately following the designation indicates the year of ori
2、ginaladoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A superscriptepsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers carbon steel overboard dis-charge hul
3、l penetrations for system piping of NPS 1 throughNPS 24 (see Note 1).NOTE 1The dimensionless designator NPS (nominal pipe size) hasbeen substituted in this standard for such TRADITIONAL terms asnominal diameter, size, and nominal size.1.2 The minimum pipe schedule and reinforcement dimen-sions prese
4、nted in Tables 1-6 are based on specifications in 46CFR, 56.50-95 and Navy Design Data Sheet 100-1.1.3 This specification does not include sea chest penetra-tions.1.4 This specification does not include penetrations inprotective plating.2. Referenced Documents2.1 ASTM Standards:2A519 Specification f
5、or Seamless Carbon and Alloy SteelMechanical Tubing2.2 ANSI Standard:B36.10 Welded and Seamless Wrought Steel Pipe32.3 Military Document:MIL-STD-1689 Fabrication, Welding, and Inspection ofShips Structure42.4 Other Documents:Title 46 Code of Federal Regulations (CFR), Subchapter F,Marine Engineering
6、4Department of the Navy, Bureau of Ship Design Data Sheet100-15ABS Rules for Building and Classing Steel Vessels63. Classification3.1 Type INonreinforced penetrations. Table 1 providesminimum schedules for the penetration pipe. See Fig. 1 fordetails of the penetration.3.2 Type IIDoubler plate-reinfo
7、rced penetrations. Table 2provides minimum dimensions for doubler plates.3.2.1 Class 1Inboard doubler plates. (Fig. 2)3.2.2 Class 2Outboard doubler plates. (Fig. 3)3.3 Type IIIInsert plate-reinforced penetrations. Table 3provides minimum dimensions for insert plates.3.3.1 Class 1Single-bevel insert
8、plates. (Fig. 4)1This specification is under the jurisdiction of ASTM Committee F25 on Shipsand Marine Technology and is the direct responsibility of Subcommittee F25.11 onMachinery and Piping Systems.Current edition approved April 1, 2011. Published April 2011. Originallyapproved in 1986. Last prev
9、ious edition approved in 2006 as F994 86 (2006).DOI: 10.1520/F0994-86R11.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe A
10、STM website.3Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.org.4Available from Standardization Documents Order Desk, DODSSP, Bldg. 4,Section D, 700 Robbins Ave., Philadelphia, PA 19111-5098, http:/dodssp.daps.dla.mil.5Availa
11、ble from Department of the Navy, Naval Sea Systems Command,Washington, DC 20362.6Available from American Bureau of Shipping (ABS), ABS Plaza, 16855Northchase Dr., Houston, TX 77060, http:/www.eagle.org.TABLE 1 Pipe Schedule for Type 1 Penetrations, NPS 1 ThroughNPS 24APene-trationPipe Size,NPSShell
12、Plating Thickness (T), in.583478 1118 1 138 11 80 80 160 160 160 160 XXS XXS XXS1 80 160 160 160 XXS XXS XXS XXS XXS1 80 160 160 160 160 XXS XXS XXS XXS2 80 160 160 160 160 160 160 XXS XXS2 80 80 160 160 160 160 160 XXS XXS3 80 80 160 160 160 160 160 160 XXS4 80 80 120 120 120 120 160 160 1605 80 80
13、 80 120 120 120 120 160 1606 80 80 80 120 120 120 120 120 1608 80 80 80 80 100 100 100 120 12010 60 60 60 80 80 100 100 100 12012 60 60 60 80 80 80 100 100 10014 60 60 60 80 80 80 80 100 10016 40 60 60 60 80 80 80 80 10018 40 40 60 60 60 80 80 80 8020 40 40 60 60 60 60 80 80 8022 40 40 60 60 60 60 8
14、0 80 8024 40 40 60 60 60 60 60 60 80ASee Fig. 1.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3.3.2 Class 2Double-bevel insert plates. (Fig. 5)3.4 Type IVSleeve-reinforced penetrations. Fig. 6 detailssleeve-reinforced penetrations.
15、3.4.1 Class 1Sleeves of nonmachined steel tube. Table 4provides minimum dimensions for nonmachined sleeves.3.4.2 Class 2Sleeves of machined steel tube or pipe.Table 5 provides minimum dimensions for machined sleeves.3.4.3 Class 3Sleeves of rolled steel flatbar or plate. Table6 provides minimum dimen
16、sions for rolled sleeves.4. Materials4.1 Discharge pipe shall be of an acceptable material asspecified by Title 46 CFR, 56.60-1.4.2 Doubler and insert plates shall be of material withphysical properties equal to or better than the reinforced shellplate.4.3 Reinforcing sleeve material shall depend on
17、 the penetra-tion pipe size:Penetration Pipe Size Sleeve MaterialNPS 1 through NPS 10 Seamless Steel Tubing, SpecificationA519.NPS 12 through NPS 18 Machined seamless steel pipe of samematerial as penetration pipe.NPS 20 through NPS 24 Steel flatbar or plate of same orsuperior material as hull plate
18、,manufactured with a full pene-tration, longitudinal butt weld.5. General Requirements General Requirements5.1 Overboard discharges shall be combined to the maxi-mum extent practicable to minimize the number of shellpenetrations.5.2 A minimum of 3 in. shall be maintained between theedge of penetrati
19、ons and shell plate welding seams. Penetra-tions shall be located so as to provide sufficient space forwelding between the penetration and shell longitudinals, stiff-eners, or other structural members.TABLE 2 Doubler Plate Dimensions (TD3 D) Type II Penetration, NPS 1 Through NPS 24 (in. 3 in.)APene
20、tratingPipe Size,NPS, SCHShell Plating Thickness (T), in.to583478 1118 1 138 11, 80 3 538 3 53 558 3 534 3 534 3 513 513 513 51, 80 3 638 3 63 658 3 634 3 634 3 613 613 613 61, 80 3 638 3 3 658 3 634 3 634 3 3 3 3 62, 80 3 738 3 73 758 3 734 3 734 3 713 713 713 72, 80 3 738 3 3 758 3 734 3 734 3 3 3
21、 3 73, 80 3 838 3 83 858 3 834 3 834 3 813 813 813 84, 80 3 938 3 93 958 3 934 3 934 3 913 913 913 95, 80 3 1038 3 10 3 1058 3 1034 3 1034 3 10 1 3 10 1 3 10 1 3 106, 80 3 1238 3 12 3 1258 3 1234 3 1234 3 12 1 3 12 1 3 12 1 3 128, 80 3 1438 3 14 3 1458 3 1434 3 1434 3 14 1 3 14 1 3 14 1 3 1410, 60 3
22、 1638 3 16 3 1658 3 1634 3 1634 3 16 1 3 16 1 3 16 1 3 1612, 60 3 1838 3 18 3 1858 3 1834 3 1834 3 18 1 3 18 1 3 18 1 3 1814, 60 3 2038 3 20 3 2058 3 2034 3 2034 3 20 1 3 20 1 3 20 1 3 2016, 40 3 2238 3 22 3 2258 3 2234 3 2234 3 23 1 3 22 1 3 23 1 3 2418, 40 3 2438 3 24 3 2458 3 2434 3 2434 3 25 1 3
23、 24 1 3 25 1 3 2820, 40 3 2638 3 26 3 2658 3 2634 3 2634 3 27 1 3 26 1 3 27 1 3 3022, 60 3 2838 3 28 3 2858 3 2834 3 2834 3 29 1 3 28 1 3 29 1 3 3224, 40 3 3038 3 30 3 3058 3 3034 3 3034 3 31 1 3 30 1 3 31 1 3 33ASee Fig. 2 and Fig. 3.TABLE 3 Insert Plate Dimensions (TI3 D), NPS 1 Through NPS 24 (in
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF99419862011STANDARDSPECIFICATIONFORDESIGNANDINSTALLATIONOFOVERBOARDDISCHARGEHULLPENETRATIONCONNECTIONS

链接地址:http://www.mydoc123.com/p-537687.html