ASTM F884-2001(2016) Standard Test Method for Motor Life Evaluation of a Built-In (Central Vacuum) Vacuum Cleaner《评估内置式 (中央真空) 真空吸尘器发动机寿命的标准试验方法》.pdf
《ASTM F884-2001(2016) Standard Test Method for Motor Life Evaluation of a Built-In (Central Vacuum) Vacuum Cleaner《评估内置式 (中央真空) 真空吸尘器发动机寿命的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM F884-2001(2016) Standard Test Method for Motor Life Evaluation of a Built-In (Central Vacuum) Vacuum Cleaner《评估内置式 (中央真空) 真空吸尘器发动机寿命的标准试验方法》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F884 01 (Reapproved 2016) An American National StandardStandard Test Method forMotor Life Evaluation of a Built-In (Central Vacuum) VacuumCleaner1This standard is issued under the fixed designation F884; the number immediately following the designation indicates the year of originaladop
2、tion or, in the case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.Asuperscriptepsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method is limited to motor life evaluation ofcentral vacuum cleane
3、rs.1.2 This test method provides a test to determine operatinglife of the motor, before servicing is needed, by an acceleratedlaboratory procedure. The motor is tested while mounted and isoperated in central vacuum cleaner.1.3 The values as stated in inch-pound units are to beregarded as the standar
4、d. The values in parentheses are forinformation only.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility o
5、f regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E337 Test Method for Measuring Humidity with a Psy-chrometer (the Measurement of Wet- and Dry-Bulb Tem-peratures)F431 Specification for Air Performance Measurement Ple-num Chamber for Vacuum CleanersF608 Test Method for
6、 Evaluation of Carpet Embedded DirtRemoval Effectiveness of Household/CommercialVacuum Cleaners3. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 failuremotor stoppage.3.1.2 motor lifelimited by the failure of the motor. Anyfailure integral with motor, such as armature assembly,
7、fieldassembly, housing(s), bearings, motor cooling fan and primaryair moving fan, or both, brush assemblies, motormountednonresetable thermal protection devices, or any other compo-nent judged to be integral with the motor, shall be judged asmotor stoppage.4. Significance and Use4.1 The test results
8、 provide an indication of the motor life ofan electric vacuum cleaner. The end of the motor life will bejudged in accordance with Section 3.5. Apparatus and Materials5.1 Voltage Regulator Systemto control the input voltageto the vacuum cleaner. The regulator must be capable ofmaintaining the Central
9、 Vacuums rated voltage 61 % andrated frequency 61 Hz with a waveform that is essentiallysinusoidal with 3 % maximum harmonic distortion for theduration of the test.5.2 Voltmeter, to provide measurements accurate to within61%5.3 Timer and SwitchThe timer and switch shall have thecapacity to control t
10、he off/on duty cycle of the cleaner duringthe life test.5.4 Sharp Edge Orifice PlateThe orifice, 0.75 in. (19.05mm) in diameter, shall be in accordance with the figureillustrating orifice plate detail in Specification F431.5.5 Wattmeter, to provide measurements accurate to within1%.5.6 Plenum Chambe
11、r, in accordance with the plenum cham-ber described in Specification F431.5.7 Water Manometer, or equivalent instrument measuringin increments of 0.1 in. (2.54 mm).5.8 Barometer, with an accuracy to 60.05 in. (1.27 mm) Hg,capable of measuring uncorrected barometric pressure (teststation pressure) wi
12、th scale division 0.02 in. (0.51 mm) or finer.5.9 Thermometer, having a range from 18 to 80F (8 to27C) and graduated in 1F (0.5C) increments.5.10 PsychrometerThe psychrometer shall meet the re-quirements of Test Method E337 with thermometers graduatedin increments of 1F (0.5C).1This test method is u
13、nder the jurisdiction ofASTM Committee F11 on VacuumCleaners and is the direct responsibility of Subcommittee F11.30 on Durability-Reliability.Current edition approved Oct. 1, 2016. Published October 2016. Originallyapproved in 1990. Last previous edition approved in 2011 as F884 01 (2011).DOI: 10.1
14、520/F0884-01R16.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor
15、 Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States15.11 Test FixtureAny suitable surface that will support thevacuum cleaner in the normal operating position.6. Sampling6.1 Test a minimum of three units (or a larger sample size ifdesired) of similar models using the same motor styl
16、e andamperage. Select all samples at random in accordance withgood statistical practice. Results shall provide an 80 % confi-dence level within 610 % of the mean value. If not, testadditional samples or reduce the results by the penalty factor ascalculated in 7.9.7. Procedures for Motor Life Evaluat
17、ion7.1 Determine initial performance as follows:7.1.1 Connect the manometer (or equivalent) to the plenumchamber. Install a new filter bag in the test cleaner, if required,before conducting performance tests.7.1.2 With a minimum length of 2 in. inside diameter tubingsealed to the plenum chamber and
18、to the cleaner, and withoutan orifice plate in the holder, energize the cleaner at its ratedvoltage 61 % and rated frequency 61 Hz for 5 min to stabilizemotor temperatures. For vacuum cleaners with dual nameplatevoltage rating, conduct testing at the highest voltage.7.1.3 With the cleaner operating
19、at a constant rated voltage,insert the 0.75-in. (19.05-mm) diameter sharp-edge orifice intothe holder on the orifice box.7.1.4 Record the suction and input power in that order assoon as the manometer reading stabilizes.7.1.4.1 Take the manometer reading as soon as the manom-eter reaches a true peak.
20、 (On higher manometer readings, theliquid level may peak, drop, and peak a second time. Thesecond peak is the true peak reading. A person conducting thetest for the first time shall observe at least one run beforerecording data. See Specification F431 for instructions on howto minimize the overshoot
21、 (first peak) of the liquid level).7.1.4.2 Take all readings within 10 s of the orifice plateinsertion.7.1.5 The input power reading is used to monitor the cleanerload.7.1.6 Monitor the input power, the suction, or both, dailyand measure on the plenum chamber every 168 h to ensure thata load is main
22、tained; that no mechanical problem has devel-oped; and that the performance has not degraded by more than40 %. If degradation exceeds 40 %, see 7.7.1 and 7.7.2.7.2 Install the cleaner on the test fixture with a 0.75-in.(19.05-mm) diameter sharp-edge orifice in the cleaner inletopening.7.3 If various
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF88420012016STANDARDTESTMETHODFORMOTORLIFEEVALUATIONOFABUILTINCENTRALVACUUMVACUUMCLEANER 评估 内置 中央

链接地址:http://www.mydoc123.com/p-537480.html