《ASTM F1927-2007 Standard Test Method for Determination of Oxygen Gas Transmission Rate Permeability and Permeance at Controlled Relative Humidity Through Barrier Materials Using a .pdf》由会员分享,可在线阅读,更多相关《ASTM F1927-2007 Standard Test Method for Determination of Oxygen Gas Transmission Rate Permeability and Permeance at Controlled Relative Humidity Through Barrier Materials Using a .pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F 1927 07Standard Test Method forDetermination of Oxygen Gas Transmission Rate,Permeability and Permeance at Controlled Relative HumidityThrough Barrier Materials Using a Coulometric Detector1This standard is issued under the fixed designation F 1927; the number immediately following th
2、e designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers
3、 a procedure for determinationof the rate of transmission of oxygen gas, at steady-state, at agiven temperature and %RH level, through film, sheeting,laminates, co-extrusions, or plastic-coated papers or fabrics.This test method extends the common practice dealing withzero humidity or, at best, an a
4、ssumed humidity. Humidity playsan important role in the oxygen gas transmission rate (O2GTR)of many materials. This test method provides for the determi-nation of oxygen gas transmission rate (O2GTR), the per-meance of the film to oxygen gas (P8O2), the permeationcoefficient of the film to its thick
5、ness (PO2), and oxygenpermeability coefficient (P9O2) in the case of homogeneousmaterials at given temperature and %RH level(s).1.2 The values stated in SI units are to be regarded as thestandard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use
6、. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. Specific precau-tionary statements are given in Section 9.2. Referenced Documents2.1 ASTM Standards:2D 1898 Practice f
7、or Sampling of Plastics3D 3985 Test Method for Oxygen Gas Transmission RateThrough Plastic Film and Sheeting Using a CoulometricSensorE 104 Practice for Maintaining Constant Relative Humidityby Means of Aqueous SolutionsE 691 Practice for Conducting an Interlaboratory Study toDetermine the Precision
8、 of a Test Method3. Terminology3.1 Definitions:3.1.1 oxygen permeability coeffcient (P9O2)the productof the permeance and the thickness of the film. The permeabil-ity is meaningful only for homogeneous materials, in whichcase it is a property characteristic of the bulk material. Thisquantity should
9、not be used unless the relationship betweenthickness and permeance has been verified on tests usingseveral different thicknesses of the material. The SI unit ofoxygen permeability is the mol/msPa.Thetest conditions(see 3.1.4) must be stated.3.1.2 oxygen permeance (P8O2)the ratio of O2GTR to thediffe
10、rence between the partial pressure of O2on the two sidesof the film. The SI unit of permeance is the mol/m2 s Pa. Thetest conditions (see 3.1.4) must be stated.3.1.3 oxygen permeation coeffcient (PO2)the ratio ofO2GTR to the thickness of the film. The SI unit of permeanceis the mol/m2 s cm. The perm
11、eation coefficient is meaningfulonly for homogeneous materials, in which case it is a propertycharacteristic of the bulk material. This quantity should not beused unless the relationship between thickness and transmis-sion rate is known.3.1.4 oxygen transmission rateat a given temperature and%RH (O2
12、GTR), the quantity of oxygen gas passing through aunit area of the parallel surfaces of a plastic film per unit timeunder the conditions of test. The SI unit of transmission rate isthe mol/m2 s. The test conditions, including temperature,%RH and oxygen partial pressure on both sides of the filmmust
13、be stated.3.1.5 transmission rate (O2GTR)a commonly used metricunit of O2GTR is the cm3(STP)/m2 d at one atmospherepressure differential where: 1 cm3(STP) is 44.62 mol, 1 atm is0.1013 MPa, and one day is 86.4 3 103s. O2GTR in SI unitsis obtained by multiplying the value in metric units by1This test
14、method is under the jurisdiction of ASTM Committee F02 on FlexibleBarrier Packaging and is the direct responsibility of Subcommittee F02.10 onPermeation.Current edition approved Aug. 1, 2007. Published August 2007. Originallyapproved in 1998. Last previous edition approved in 2004 as F 1927 98 (2004
15、).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Withdrawn.1Copyright ASTM International, 100 Barr Harbor D
16、rive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5.165 3 10-10or the value in inch-pound units (cm3/STP/100in.2 d) by 8.005 3 10-9.4. Summary of Test Method4.1 The oxygen gas transmission rate is determined after thesample has equilibrated in a given temperature and humidityenviron
17、ment.4.2 The specimen is mounted as a sealed semi-barrierbetween two chambers at ambient atmospheric pressure. Onechamber is slowly purged by a stream of nitrogen at a giventemperature and %RH and the other chamber is purged by astream of oxygen at the same temperature as the N2stream butmay have a
18、different %RH than the N2stream. In this case theenvironment would more closely simulate actual shelf condi-tions. As oxygen gas permeates through the film into thenitrogen carrier gas, it is transported to the coulometricdetector where it produces an electrical current, the magnitudeof which is pro
19、portional to the amount of oxygen flowing intothe detector per unit time.5. Significance and Use5.1 O2GTR at a given temperature and %RH is an importantdeterminant of the packaging protection afforded by barriermaterials. It is not, however the sole determinant, and addi-tional tests, based on exper
20、ience, must be used to correlatepackaging performance with O2GTR. It is suitable as a refereemethod of testing, provided that purchaser and seller haveagreed on sampling procedures, standardization procedures,test conditions and acceptance criteria.6. Interferences6.1 The presence of certain interfe
21、ring substances in thecarrier gas stream may give rise to unwanted electrical outputsand error factors. Interfering substances include free chlorineand some strong oxidizing agents. Exposure to carbon dioxideshould also be minimized to avoid damage to the sensorthrough reaction with the potassium hy
22、droxide electrolyte.7. Apparatus7.1 Oxygen Gas Transmission Apparatus, as diagramed inFig. 1 and described following. Alternative systems need to beevaluated to ensure equivalent performance.7.1.1 Diffusion Cell, consisting of two metal halves, that,when closed upon the test specimen, will accuratel
23、y define acircular area. Typical acceptable diffusion cell areas are 100and 50 cm2. The volume enclosed by each cell half, whenclamped, is not critical: it should be small enough to allow forrapid gas exchange, but not so small that an unsupported filmwhich happens to sag or bulge will contact the s
24、ides of the cell.The diffusion cell shall be provided with a temperaturemeasuring and controlling capability and a means to measureand control relative humidity.7.1.1.1 Temperature control is critical because RH can varyas much as 5 % RH/C in certain temperature regions. Acompact design of the diffu
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF19272007STANDARDTESTMETHODFORDETERMINATIONOFOXYGENGASTRANSMISSIONRATEPERMEABILITYANDPERMEANCEATCONTROLLEDRELATIVEHUMIDITYTHROUGHBARRIERMATERIALSUSINGAPDF

链接地址:http://www.mydoc123.com/p-536057.html