《ASTM F1843-2015 Standard Practice for Sample Preparation of Plastic Films used on Membrane Switch Overlays for Specular Gloss Measurements《镜面光泽测量用薄膜开关覆盖层使用塑料膜样品制备的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM F1843-2015 Standard Practice for Sample Preparation of Plastic Films used on Membrane Switch Overlays for Specular Gloss Measurements《镜面光泽测量用薄膜开关覆盖层使用塑料膜样品制备的标准实施规程》.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F1843 15Standard Practice forSample Preparation of Plastic Films used on MembraneSwitch Overlays for Specular Gloss Measurements1This standard is issued under the fixed designation F1843; the number immediately following the designation indicates the year oforiginal adoption or, in the
2、case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers the method of sample preparation,prior to taking gloss measurements
3、 on a membrane switchoverlay.1.2 Typical applications include window display areas on agraphic overlay, and surface texture.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appr
4、o-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D523 Test Method for Specular Gloss3. Terminology3.1 Definitions:3.1.1 membrane switch, na momentary switching devicein which at least one contact i
5、s on (or made of) a flexiblesubstrate.3.1.2 specular gloss, nthe degree to which a surfacesimulates a perfect mirror in its capacity to reflect incidentlight.3.1.3 overlay, nthe outer layer of a membrane switch onwhich the graphics are printed.4. Summary of Practice4.1 A water or alcohol droplet is
6、placed on a black metalplate. The specimen to be measured is pressed down over thedroplet. Capillary action causes intimate contact betweenspecimen and plate, thereby eliminating second surface reflec-tion. Gloss readings may then be taken in accordance with TestMethod D523.5. Significance and Use5.
7、1 Gloss measurements are used to qualify a raw materialor finished product.5.2 Sample preparation will effect the outcome of glossreadings. This practice will eliminate second surface reflection,and allow a more accurate gloss reading of the substrate.5.3 Materials which require this preparation inc
8、lude thefollowing: clear or translucent substrates, colored transparentsubstrates, and areas printed with clear, translucent, or trans-parent colored coatings.6. Apparatus6.1 Gloss Meter, in accordance with Test Method D523.6.2 Black Iodized Aluminum Test Plate3, This plate is to bea hard, flat, smo
9、oth, matte black, nonporous surface. Glossreadings should be between 4 to 12 gloss units, when measuredwith a 60 gloss meter. Plate size should be sufficient to allowthe specimen to be laid flat for readings, typically 12 by 12 in.(304.8 by 304.8 mm). Material thickness to be 0.062 in. ( 1.57mm) or
10、thicker.6.3 Distilled Water, or Isopropyl Alcohol.6.4 Eye Dropper.6.5 Hand Held Brayer (rubber roller).7. Procedure7.1 Verify the specimen and plate are clean, dry, and free ofcontamination.7.2 Use the eyedropper to place a few drops of distilledwater or isopropyl alcohol in the center of the black
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF18432015STANDARDPRACTICEFORSAMPLEPREPARATIONOFPLASTICFILMSUSEDONMEMBRANESWITCHOVERLAYSFORSPECULARGLOSSMEASUREMENTS

链接地址:http://www.mydoc123.com/p-535825.html