ASTM F1721-2004 Standard Practices for Determining Stability of Direct Thermal Imaging Products《测定直热式图像制品稳定性的标准规程》.pdf
《ASTM F1721-2004 Standard Practices for Determining Stability of Direct Thermal Imaging Products《测定直热式图像制品稳定性的标准规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM F1721-2004 Standard Practices for Determining Stability of Direct Thermal Imaging Products《测定直热式图像制品稳定性的标准规程》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F 1721 04Standard Practices forDetermining Stability of Direct Thermal Imaging Products1This standard is issued under the fixed designation F 1721; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revis
2、ion. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 These practices cover the evaluation of the effect ofvarious solvents, light, heat, and humidity on direct thermalimaging produ
3、cts.1.2 These practices may be used to evaluate the perfor-mance of thermal products coated on paper, film, or othersubstrate for specific applications.1.3 These practices may be used for manufacturing control,development, and research.1.4 The sections in these practices appear in the followingseque
4、nce:Scope 1Referenced Documents 2Terminology 3PracticesSolvent Resistance 411Light Stability 1218Heat and Humidity Stability 1925Keywords 261.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard t
5、o establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D 2244 Test Method for Calculation of Color Differencesfrom Instrumentally Measured ColorF 767 Test Method for Image Stability of Ch
6、emical Carbon-less Paper to LightF 1320 Test Method for Evaluating Thermal Paper Employ-ing a Facsimile Thermal Printer as a Test InstrumentF 1405 Test Method for Determining the Dynamic ThermalResponse of Direct Thermal Imaging ProductsAtlantekMethodF 1444 Test Method for Determining the Dynamic Th
7、ermalResponse of Direct Thermal PaperLabel Printer Method2.2 ANSI Standard:ANSI/CGATS 4-1993 Graphic TechnologyGraphic ArtsReflection Densitometry MeasurementsTerminology,Equations, Image Elements and Procedures33. Terminology3.1 Definition:3.1.1 direct thermal imaging product, npaper, film, orother
8、 substrate upon which a coating is applied; the imagingcomponents consist of a color former (leuco dye), a developer,a sensitizer, and antioxidants which react to form an imagewhen sufficiently heated from a thermal printhead.SOLVENT RESISTANCE4. Summary of Practice4.1 Select one or more of the solv
9、ents appropriate to theapplication for which the product will be used.4.2 Imaged samples including a control are measured foroptical density then subjected to contact by various solventmaterials for a specified time. Optionally, L*,a*,b* values canbe measured for the background using a spectrodensit
10、ometer.After the test time is completed, the samples are againmeasured for optical density and L*,a*,b* and compared to acontrol. The L*,a*,b* measurements will indicate changes inimage color.4.2.1 Most units which measure L*,a*,b* can provide thedifference values in the form of DL*, Da*, Db* and DE
11、. Referto the technical literature on color measurement for theinterpretation of these results.5. Significance and Use5.1 These procedures enable comparison of samples with acontrol under various solvent conditions to determine thestability of the image. The various solvents simulate conditionswhich
12、 may be encountered in the environment.5.2 The test may be used to judge which materials aresuitable for a specific situation and usage. The sensitivity of theproducts should match and the products should be for the sameapplication.1These practices are under the jurisdiction of ASTM Committee F05 on
13、Business Imaging Products and are the direct responsibility of SubcommitteeF05.06 on Carbonless and Thermal Imaging Products.Current edition approved Feb. 1, 2004. Published April 2004. Originallyapproved in 1996. Last previous edition approved in 1996 as F 172196.2For referenced ASTM standards, vis
14、it the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American National Standards Institute, 25 W. 43rd St., 4thFloor, New York, NY 10
15、036.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5.3 The procedure may be used for the evaluation of directimaging coatings on paper, film, or other substrate. The methodof imaging should be with the type of imaging unit for which
16、the product has been designed.6. Interferences6.1 Backing material will affect the reading taken with aspectrodensitometer. Specify which backing is used whentaking a reading.6.2 When reading L*,a*,b* values, also record observer,illuminator, and geometry of the instrument.7. Apparatus and Materials
17、7.1 Spectrodensitometer, with an aperture smaller than theimage area to be measured and meeting the requirements ofANSI/CGATS 4-1993, operating in visual density mode.7.2 Oven, operated at 100 6 4F (38 6 2C).7.3 Printer or Alternative Imaging Device.7.4 Weight2.5 lb/in.2(0.176 kg/cm2).7.5 PVC Film.7
18、.6 Cottonseed Oil.7.7 Castor Oil.7.8 Saturated Salt Solution.7.9 Ethyl Alcohol, 20 % v/v water, denatured.7.10 Isopropyl Alcohol.7.11 Pipette.7.12 OptionInstrument for the measurement of L*,a*,b*.8. Test Specimens8.1 The test specimens and control shall be sheets or takenfrom a roll of direct therma
19、l imaging product.8.2 Cut samples into individual sheets approximately 812 by11 in. (216 by 279 mm). A maximum of six sheets per sampleare required for testing.8.3 Employ a control sample whose characteristics havebeen previously established or to which all results will becompared.9. Calibration9.1
20、SpectrodensitometerCalibrate the densitometer in ac-cordance with the manufacturers recommendations.9.2 OptionL*,a*,b* InstrumentCalibrate the unit inaccordance with the manufacturers recommendations.10. Procedure10.1 Image the samples and control with a printer to providea series of images. Imaging
21、 may be achieved with a facsimilethermal printer employing a suitable test target (see TestMethod F 1320) or by imaging systems described in TestMethods F 1405 or F 1444. If possible, have some images be asolid block at least14 by14 in. (0.6 by 0.6 cm). Image allsamples in the same manner.10.2 Using
22、 the reflectance spectrodensitometer, measure theimage density of the samples and control after full densitydevelopment. Optionally, L*,a*,b* values may be measuredfor the background. A minimum of five measurements shouldbe taken and averaged to improve accuracy. Measurementsshould be made in the sa
23、me relative location on each sample.10.3 Wrap each imaged sample and imaged control withthree layers of PVC film, taking care to keep the samples flatand the film wrap wrinkle free. Place samples in an ovenestablished at 100 6 4F (386 2C) under a weight of 2.5lb/in.2for 16 h.10.4 Coat an imaged samp
24、le and imaged control withcottonseed oil or castor oil and place in an oven established at100 6 4F (38 6 2C) for 16 h. Use a pipet or similar deviceto ensure that an equivalent amount of oil is applied to eachsample.10.5 Immerse imaged sample and imaged control in waterfor 16 h at room temperature.
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便