ASTM F1482-2015 Standard Practice for Installation and Preparation of Panel Type Underlayments to Receive Resilient Flooring《安装和制备用于承接弹性地板的厚板类衬垫材料的标准实践规程》.pdf
《ASTM F1482-2015 Standard Practice for Installation and Preparation of Panel Type Underlayments to Receive Resilient Flooring《安装和制备用于承接弹性地板的厚板类衬垫材料的标准实践规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM F1482-2015 Standard Practice for Installation and Preparation of Panel Type Underlayments to Receive Resilient Flooring《安装和制备用于承接弹性地板的厚板类衬垫材料的标准实践规程》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F1482 15Standard Practice forInstallation and Preparation of Panel Type Underlayments toReceive Resilient Flooring1This standard is issued under the fixed designation F1482; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revisi
2、on, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice includes recommendations for the instal-lation of panel type underlayments including woo
3、d based, fiberreinforced gypsum and fiber-cement panel underlayment/subfloor assemblies upon which resilient flooring may beinstalled.1.2 The structural integrity of subfloor assemblies is gov-erned by local building codes.1.3 This practice does not supersede in any manner theresilient flooring, und
4、erlayment or adhesive manufacturerswritten instructions. Consult the individual resilient flooring,underlayment or adhesive manufacturer for specific recom-mendations. Manufacturers instructions supercede the recom-mendations included in this practice.1.4 See Supplementary Requirements for “Select W
5、arnings”that have been provided.1.5 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.6 This standard does not purport to address all of
6、thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C1278/C1278M Specificatio
7、n for Fiber-Reinforced GypsumPanelC1288 Specification for Discrete Non-Asbestos Fiber-Cement Interior Substrate SheetsF141 Terminology Relating to Resilient Floor Coverings2.2 ANSI Standards:ANSI/A208.1 Particleboard3ANSI/AHA A135.4 Basic Hardboard32.3 NIST Standards:Voluntary Product Standard PS 1-
8、10 for StructuralPlywood3,4Voluntary Product Standard PS 2-10 for Performance Stan-dard Wood-Based Structural-Use Panels3,42.4 Other Documents:APA Engineered Wood Construction Guide, Form E305APA Data File: Selection, Installation and Preparation ofPlywood Underlayment Form L3355Resilient Floor Cove
9、ring Institute (RFCI) RecommendedWork Practices for Removal of Resilient Floor Coverings(January 1998)6Lead-Based Paint: Interim Guidelines for Hazard Identifi-cation and Abatement in Public and Indian housing (1991revised)73. Terminology3.1 Definitions used in this standard shall be in accordancewi
10、th Terminology F141.3.2 Definitions of Terms Specific to This Standard:3.2.1 fully adhered flooringresilient flooring which hasadhesive under the entire product, bonding it to the underlay-ment surface.3.2.2 non fully adhered flooringresilient flooring that maybe loose laid, in which no adhesive is
11、utilized, or partiallybonded to the surface of the underlayment, typically at seamsor the surrounding perimeter, or both, of the product.1This guide is under the jurisdiction ofASTM Committee F06 on Resilient FloorCoverings and is the direct responsibility of Subcommittee F06.40 on Practices.Current
12、 edition approved April 15, 2015. Published June 2015. Originallyapproved in 1994. Last previous edition approved in 2009 as F1482 04(2009)1.DOI: 10.1520/F1482-15.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book
13、 of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.org.4Available from National Institute of Standards and Technology (NIST),
14、100Bureau Dr., Stop 1070, Gaithersburg, MD 20899-1070, http:/www.nist.gov.5Available from APAThe Engineered Wood Association, 7011 S. 19th St.,Tacoma, WA 984665399, www.apawood.org.6Resilient Floor Covering Institute, 401 E. Jefferson Suite 102 Rockville, MD20850, .7U.S. Department of Housing that i
15、s, at the seam orperimeter areas, or both. Non fully adhered resilient flooringproducts may permit a wider selection of underlayments to beutilized.6.6 The panel underlayment shall be smooth enough so thatthe texture of the graining or particle placement in the panelwill not show through the finishe
16、d resilient flooring. Theunderlayment panels shall not contain any foreign substance ormarkings that may stain the resilient flooring after installation.Protective coatings that may be used on underlayment panelsshall be non-staining and be compatible with adhesives usedfor installing the finished f
17、looring. Panels should not containpreservatives (pressure treated).6.7 Responsibility for appearance or performance relatedissues that arise from use of panel underlayment outside theresilient manufacturers recommendations, typically fall backto the underlayment panel manufacturer or whoever selecte
18、d orspecified the panel underlayment to be used. Following theresilient flooring manufacturers published guidelines is rec-ommended.6.8 Responsibility for appearance or performance relatedissues that arise from patching, leveling or adhesive com-pounds outside the resilient manufacturers recommendat
19、ions,typically fall back to the supplier of those materials or whoeverselected or specified those materials. Following the resilientmanufacturers published guidelines is recommended.7. Material Acceptance7.1 DeliveryAll materials shall be delivered in packages,containers, or bundles with the identif
20、ication and markingsintact.7.2 InspectionInspection of the materials shall be agreedupon between the purchaser and the supplier as part of thepurchase agreement.7.3 RejectionMaterials that are damaged, wet, frozen or inany way defective shall not be used. Rejection of materialsshall be promptly repo
21、rted verbally to the producer andF1482 152immediately reported in writing. The notice of rejection shallcontain a statement documenting the basis for material rejec-tion.7.4 CertificationWhen specified in the contractdocuments, the panel underlayment producer shall furnish areport certifying that th
22、e materials are in conformance withproduct and material standards and contract documents. Thepanel underlayment shall be marked as complying with theapplicable product specification.8. Material Storage and Conditioning8.1 All materials shall be kept dry by storage under coverand protected from the w
23、eather. Outside storage is not recom-mended.8.2 All other underlayment components shall be stacked offthe ground, flat and with care taken to avoid damage to edges,ends or surface. It should be supported on a level platform andprotected from direct sunlight, weather, surface contaminationor physical
24、 damage in accordance with the producers writteninstructions.8.3 Materials shall be protected from exposure to tempera-tures less than 40F (4C) unless otherwise specified by theproducer.8.4 Gypsum-based or Portland cement patching and level-ing compounds, or both, shall be kept dry until ready for u
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF14822015STANDARDPRACTICEFORINSTALLATIONANDPREPARATIONOFPANELTYPEUNDERLAYMENTSTORECEIVERESILIENTFLOORING

链接地址:http://www.mydoc123.com/p-534971.html