《ASTM F1450-2005 Standard Test Methods for Hollow Metal Swinging Door Assemblies for Detention Facilities《拘留装置用空心金属转动门组合件的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM F1450-2005 Standard Test Methods for Hollow Metal Swinging Door Assemblies for Detention Facilities《拘留装置用空心金属转动门组合件的标准试验方法》.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F 1450 05Standard Test Methods forHollow Metal Swinging Door Assemblies for Detention andCorrectional Facilities1This standard is issued under the fixed designation F 1450; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revisio
2、n, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 These test methods cover requirements for mechanicaltests, simulated service test, and testing equipme
3、nt for deter-mining the performance characteristics of swinging detentionhollow metal door assemblies of various styles and types ofconstruction for use in wall openings designed to incarcerateinmates in detention/correctional institutions.1.2 These test methods test the capability of a swinging doo
4、rassembly to prevent, delay, and frustrate escape, to limit orcontrol access to unauthorized or secure areas, and to resistcommon types of vandalism.1.3 These test methods apply primarily to detention doorassemblies to and from secure areas generally found insidedetention/correctional facilities, su
5、ch as: day rooms, controlrooms, cells, and sally ports.1.4 The values stated in inch-pound units are to be regardedas the standard. The values given in parentheses are forinformation only.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is
6、theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E 2074 Test Method for Fire Tests of Door Assemblies,Including Positive Pressure Tes
7、ting of Side-Hinged andPivoted Swinging Door AssembliesF 1577 Test Methods for Detention Locks for SwingingDoorsF 1592 Test Methods for Detention Hollow Metal VisionSystemsF 1643 Test Methods for Detention Sliding Door LockingDevice AssemblyF 1758 Test Methods for Detention Hinges Used onDetention-G
8、rade Swinging DoorsF 1915 Test Methods for Glazing for Detention Facilities2.2 ANSI Standard:3ANSI/NAAMM/HMMA 863 Guide Specifications for De-tention Security Hollow Metal Doors and Frames2.3 NFPA Standard:4252 Methods of Fire Tests of Door Assemblies2.4 UL Standards:5UL-10 (B) Fire Tests of Door As
9、sembliesUL-10 (C) Fire Tests of Door AssembliesUL-437 Standard for Key LocksUL-752 Bullet Resisting EquipmentUL-1034 Standard for Burglary Resistant Electric LockingMechanisms3. Terminology3.1 Definitions:3.1.1 boltmetal bar which, when actuated, is projected (orthrown) either horizontally or vertic
10、ally into a retaining mem-ber, such as a strike plate, to prevent a door from moving oropening.3.1.2 bolt projection (or bolt throw)distance from theedge of the door or frame, at the bolt center line, to the farthestpoint on the bolt in the projected position.3.1.3 componenta subassembly, as disting
11、uished from apart, that combines with other components to make up a totaldoor assembly.3.1.3.1 DiscussionThe prime components of a door as-sembly include the following: door, lock, hinges, wall, anddoor frame (includes hinge jamb, strike jamb, and header).3.1.4 detention securityassurance of the res
12、triction ofmobility of inmates to designated areas within a correctional ordetention facility.1These test methods are under the jurisdiction of ASTM Committee F33 onDetention and Correctional Facilities and are the direct responsibility of Subcom-mittee F33.02 on Physical Barriers.Current edition ap
13、proved April 1, 2005. Published April 2005. Originallyapproved in 1992. Last previous edition approved in 2004 as F 1450 97 (2004).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume informa
14、tion, refer to the standards Document Summary page onthe ASTM website.3Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036.4Available from National Fire Protection Association (NFPA), 1 BatterymarchPark, Quincy, MA 02269-9101.5Available from Unde
15、rwriters Laboratories (UL), Corporate Progress, 333Pfingsten Rd., Northbrook, IL 60062.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3.1.5 door assemblyunit composed of a group of parts orcomponents that make up an opening barrier
16、for a passagewaythrough a wall.3.1.5.1 DiscussionFor the purpose of these test methods,a door assembly consists of the following parts: door; hinges;locking device or devices; operation contacts (such as handles,knobs, or flush pulls); security glazing and glazing molding;miscellaneous hardware and
17、closers; the frame, including thehead and jambs plus anchorage devices to the surroundingwall; and a portion of the surrounding wall extending 32 in.(81.3 cm) from each side of the jambs and 16 in. (40.65 cm)above the head.3.1.6 frameassembly of members surrounding and sup-porting a door or doors.3.
18、1.7 hinged doordoor equipped with hinges that permit itto swing about the vertical hinge axis, either right-hand,left-hand, right-hand reverse bevel, or left-hand reverse bevel,depending upon hardware configuration.3.1.8 hollow metalterm used in reference to such items asdoors, frames, partitions, e
19、nclosures, and other items that arefabricated from metal sheet, typically cold-rolled or hot-rolledpickled-and-oiled carbon steel.3.1.8.1 DiscussionThese products are internally rein-forced but hollow, hence the term hollow metal. Typically, thevoids in doors and partitions are filled with insulatio
20、n. Wheninstalled in masonry walls, the voids in frame jambs, headers,and mullions may be grouted or left hollow.3.1.9 manufacturerparty responsible for the fabrication ofthe test samples.3.1.10 panelfor the purposes of these test methods, thepanel is a steel plate at least 0.375 in. (9.5 mm), instal
21、led inorder to transfer impact energy to the glazing stops and theassembly.3.1.11 performance characteristicresponse of the doorassembly in any one of the tests described herein.3.1.12 test completionconduct of one test sequence foreach of the door assemblies.3.1.13 testing laboratoryindependent mat
22、erials testinglaboratory not associated with the manufacturer.4. Significance and Use4.1 A major concern for prison administrative officials issecurity barriers used in detention/correctional facilities. Thesetest methods are designed to aid in identifying levels ofphysical security for swinging det
23、ention hollow metal doorassemblies.4.2 These test methods are not intended to provide ameasure of resistance for a door assembly subjected to attackby corrosive agents, by high-powered rifles, explosives, saw-ing, or other such methods. These test methods are intended toevaluate the resistance of a
24、door assembly to violent attacksusing battering devices, such as benches, bunks, or tables; byhandguns up to and including .44 magnum; by prying devices;by devices used to deform the door and render it inoperable;and by fires started by using mattresses, books, and otherflammable materials.4.3 The p
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF14502005STANDARDTESTMETHODSFORHOLLOWMETALSWINGINGDOORASSEMBLIESFORDETENTIONFACILITIES 拘留 装置 空心 金属

链接地址:http://www.mydoc123.com/p-534913.html