ASTM F1057-1987(2005) Standard Practice for Estimating the Quality of Extruded Poly (Vinyl Chloride) (PVC) Pipe by the Heat Reversion Technique《利用热循环技术评估压塑聚乙烯(PVC)管道质量的实施规程》.pdf
《ASTM F1057-1987(2005) Standard Practice for Estimating the Quality of Extruded Poly (Vinyl Chloride) (PVC) Pipe by the Heat Reversion Technique《利用热循环技术评估压塑聚乙烯(PVC)管道质量的实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM F1057-1987(2005) Standard Practice for Estimating the Quality of Extruded Poly (Vinyl Chloride) (PVC) Pipe by the Heat Reversion Technique《利用热循环技术评估压塑聚乙烯(PVC)管道质量的实施规程》.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F 1057 87 (Reapproved 2005)An American National StandardStandard Practice forEstimating the Quality of Extruded Poly (Vinyl Chloride)(PVC) Pipe by the Heat Reversion Technique1This standard is issued under the fixed designation F 1057; the number immediately following the designation in
2、dicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers a procedure for es
3、timating thequality of extruded poly (vinyl chloride) (PVC) plastic pipes byobserving the reaction of pipe specimens after exposure toheat.1.2 This standard does not purport to address all of thesafety problems, if any, associated with its use. It is theresponsibility of the user of this standard to
4、 establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Significance and Use2.1 This practice is applicable to distinguish between prop-erly and improperly extruded PVC plastic pipe. It can be usedto:2.1.1 Reveal incomplete exsic
5、cation of compound before orduring extrusion (Note 1),2.1.2 Determine the presence of stress in the pipe wallproduced by the extrusion process (Note 2),2.1.3 Determine whether infused areas are present, and2.1.4 Reveal contamination.NOTE 1Residual moisture in the compound vaporizes at extrusiontempe
6、ratures and is normally evacuated as it forms vapor. Pockets ofmoisture trapped in the pipe wall result from incomplete exsiccation of thecompound, and may reduce the physical properties of the pipe.NOTE 2Minor residual stress in the pipe will not impair fieldperformance and handleability. High-resi
7、dual stress has no proven effecton performance, but may impair handleability during installation.3. Apparatus3.1 Air Oven, thermostatically controlled, capable of oper-ating at 180 6 5C (356 6 9F) such that after insertion of thespecimen to be tested the test temperature is regained within 15min or
8、less.NOTE 3The oven should be vented to the outside of the building.4. Procedure4.1 Prepare specimens of pipe 150 mm (6 in.) long or longerwith ends cut square so that they stand perpendicular on endwhen placed in the oven.4.1.1 Cut staves from pipes whose size prevents insertion offull round specim
9、ens in the oven. Prepare large-diameter pipestaves so that their lengths parallel to the pipe axis are 150 mm(6 in.) or longer.4.2 Examine the specimens and note any unusual featuressuch as discoloration, inclusions, or pinholes in the cut edge.4.3 Place the specimens of whole pipe in the preheated
10、ovenso that each specimen stands on end with sufficient separationbetween them so that hot air can flow freely between the pipes.Place specimens of pipe staves on the floor of the preheatedoven so that they rest on their longitudinal edges and so that hotair can flow freely around them. Record the t
11、ime when the airin the oven recovers to 180C (356F). After an additional 30min at this temperature, remove the specimens, taking care notto alter any heat effects.4.4 Examine the specimens within 3 min after removal fromthe oven, while still hot. With a sharp knife, cut whole pipespecimens lengthwis
12、e at approximately 60 circumferentialintervals, resulting in six pipe staves of approximately equalwidths. Cut specimens being tested in the form of staves intothree roughly equal segments. Note the following for thereport:4.4.1 The shape of the pipe ends and the pipe barrel,4.4.2 The condition and
13、appearance of both the inner andouter surfaces of the material, and4.4.3 The condition and appearance of the cut edges of thematerial.5. Interpretation5.1 A suggested interpretation of the results observed isgiven in Appendix X1.6. Report6.1 Report the following information, where applicable:6.1.1 I
14、nformation given by the pipe marking, including thenominal size of pipe, the type of pipe, and the date code;6.1.2 Form in which the pipe was tested;1This practice is under the jurisdiction of ASTM Committee F17 on PlasticPiping Systems and is the direct responsibility of Subcommittee F 17.40 on Tes
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF105719872005STANDARDPRACTICEFORESTIMATINGTHEQUALITYOFEXTRUDEDPOLYVINYLCHLORIDEPVCPIPEBYTHEHEATREVERSIONTECHNIQUE

链接地址:http://www.mydoc123.com/p-534063.html