ASTM E2679-2009 Standard Test Method for Acidity in Mono- Di- Tri- and Tetraethylene Glycol by Non-Aqueous Potentiometric Titration《使用非水电位测量滴定法测定单甘醇、双甘醇、三甘醇和四甘醇酸度用标准试验方法》.pdf
《ASTM E2679-2009 Standard Test Method for Acidity in Mono- Di- Tri- and Tetraethylene Glycol by Non-Aqueous Potentiometric Titration《使用非水电位测量滴定法测定单甘醇、双甘醇、三甘醇和四甘醇酸度用标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E2679-2009 Standard Test Method for Acidity in Mono- Di- Tri- and Tetraethylene Glycol by Non-Aqueous Potentiometric Titration《使用非水电位测量滴定法测定单甘醇、双甘醇、三甘醇和四甘醇酸度用标准试验方法》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 2679 09Standard Test Method forAcidity in Mono-, Di-, Tri- and Tetraethylene Glycol byNon-Aqueous Potentiometric Titration1This standard is issued under the fixed designation E 2679; the number immediately following the designation indicates the year oforiginal adoption or, in the cas
2、e of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of totalacidity as acetic acid in commonly availa
3、ble grades of mono-ethylene glycol, diethylene glycol, triethylene glycol andtetraethylene glycol using a non-aqueous potentiometric titra-tion. This test method is useful for determining low levels ofacidity, below 200 mg/kg.1.2 The mono-, di-, tri- and tetraethylene glycols can beanalyzed directly
4、 by this test method without any samplepreparation.1.3 Review the current appropriate Material Safety DataSheets (MSDS) for detailed information concerning toxicity,first aid procedures, and safety precautions.1.4 The values stated in SI units are to be regarded asstandard. No other units of measure
5、ment are included in thisstandard.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limita
6、tions prior to use. Specific hazardsstatements are given in the section on Hazards, Section 9.2. Referenced Documents2.1 ASTM Standards:2D 1193 Specification for Reagent WaterE 180 Practice for Determining the Precision of ASTMMethods for Analysis and Testing of Industrial and Spe-cialty Chemicals3.
7、 Terminology3.1 Definition:3.1.1 aciditythe amount of total acid titrated with anaqueous base (KOH or NaOH) in a sample of ethylene glycol.The acidity is calculated as acetic acid in mg/kg.4. Summary of Test Method4.1 An aliquot of a mono-, di-, tri- or tetraethylene glycolsample is weighed and titr
8、ated potentiometrically with amonotonic or dynamic mode of titrant addition using anaqueous base (NaOH or KOH) solution to determine the acidcontent in milligrams of acid as acetic acid per kilogram ofsample. An ethylene glycol sample can be analyzed directly bythis test method without any sample pr
9、eparation using acombination pH electrode with an inert ethanol electrolytedesigned for non-aqueous titrations. The potentiometric titra-tion readings in millivolts are plotted automatically against therespective volumes of the titrating solution and the end point isidentified by a well-defined infl
10、ection in the resulting curve.5. Significance and Use5.1 This test method provides for the quantitative determi-nation of total acidity in ethylene glycols by non-aqueouspotentiometric titration. The run time for titration of ethyleneglycol samples ranges from 5 to 10 min with no samplepreparation r
11、equired. The length of time for a titration dependson the amount of acidity in the sample and the acidity generallyincreases from monoethylene glycol to the higher glycols liketetraethylene glycol.5.2 Acceptable levels of acidity in ethylene glycols varywith the manufacturers specifications but are
12、normally below200 mg/kg. Knowledge of the acidity in ethylene glycols isrequired to establish whether the product quality meets speci-fication requirements.6. Interferences6.1 Aqueous base solutions, such as the 0.01 mol/L KOH orNaOH titrant, may absorb carbon dioxide from the air toproduce carbonat
13、e ions in the titrant and change the concen-tration of the titrant. Care should be taken to minimizeexposure of basic titrants to the air. Verify the concentration ofthe titrant (standardize the titrant) if prolonged exposure to theair occurs.1This test method is under the jurisdiction of ASTM Commi
14、ttee E15 onIndustrial and Specialty Chemicals and is the direct responsibility of SubcommitteeE15.02 on Product Standards.Current edition approved April 1, 2009. Published May 2009.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.or
15、g. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.6.2 Minimize exposure of the ethylene glycol samples to theair to
16、 avoid contamination.7. Apparatus7.1 Potentiometric TitratorAutomatic titration systemscapable of adding fixed increments of titrant at fixed timeintervals (monotonic) or variable titrant increments with elec-trode stability between increment additions (dynamic) withendpoint seeking capabilities as
17、prescribed in the method. As aminimum, the automatic titration system shall meet the perfor-mance and specification requirements as warranted by themanufacturer.7.1.1 Amonotonic or dynamic mode of titrant addition shallbe used. During the titration, the speed and volume of theaddition may vary depen
18、ding on the rate of change of thesystem. The recommended minimum volume increment is 0.02mL for low acidity samples such as polyester grade monoeth-ylene glycol and the recommended maximum volume incre-ment is 0.05 mL. A signal drift of 10 mV/min and endpointrecognition set to greatest is also recom
19、mended to ensureendpoint detection. When using a monotonic titrant additionthe waiting time between increment additions needs to besufficient to allow for mixing and electrode response. It isrecommended to wait at least 10 s between additions.7.1.2 Buret, 5 mL capacity, capable of delivering titrant
20、 in0.02 mL or larger increments. The buret tip should be able todeliver titrant directly into the titration vessel without exposureto the surrounding air. It is recommended that the buret usedfor aqueous base solutions should have a guard tube containinga carbon dioxide absorbing substance.7.1.3 Tit
21、ration Stand, suitable for supporting the electrode,stirrer and buret tip.7.2 Combination pH ElectrodesSensing electrodes mayhave the Ag/AgCl reference electrode built into the sameelectrode body, which offers the convenience of working withand maintaining only one electrode. A combination pH elec-t
22、rode designed for non-aqueous titrations of organic solvents isneeded for titration of glycols. The combination pH electrodeshould have a sleeve junction on the reference compartmentand should use an inert ethanol electrolyte, 13 mol/L LiCl inethanol. Combination pH electrodes should have the same o
23、rbetter response than a dual electrode system. They should havea movable sleeve for easy rinsing and addition of electrolyte.7.3 Titration Beaker, borosilicate glass or plastic beaker ofsuitable size for the titration.7.4 Stirrer, variable-speed mechanical stirrer, a suitabletype, equipped with a pr
24、opeller-type stirring paddle. The rate ofstirring shall be sufficient to produce vigorous agitation withoutspattering and without stirring air into the solution. A propellerwith blades 6 mm in radius and set at a pitch of 30 to 45 issatisfactory. A magnetic stirrer and stirring bars is also satis-fa
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME26792009STANDARDTESTMETHODFORACIDITYINMONODITRIANDTETRAETHYLENEGLYCOLBYNONAQUEOUSPOTENTIOMETRICTITRATION

链接地址:http://www.mydoc123.com/p-531679.html