ASTM E2179-2003(2016) Standard Test Method for Laboratory Measurement of the Effectiveness of Floor Coverings in Reducing Impact Sound Transmission Through Concrete Floors《对地板覆盖物在降.pdf
《ASTM E2179-2003(2016) Standard Test Method for Laboratory Measurement of the Effectiveness of Floor Coverings in Reducing Impact Sound Transmission Through Concrete Floors《对地板覆盖物在降.pdf》由会员分享,可在线阅读,更多相关《ASTM E2179-2003(2016) Standard Test Method for Laboratory Measurement of the Effectiveness of Floor Coverings in Reducing Impact Sound Transmission Through Concrete Floors《对地板覆盖物在降.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E2179 03 (Reapproved 2016)Standard Test Method forLaboratory Measurement of the Effectiveness of FloorCoverings in Reducing Impact Sound TransmissionThrough Concrete Floors1This standard is issued under the fixed designation E2179; the number immediately following the designation indica
2、tes the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.INTRODUCTIONThis test method is part of a set for evalua
3、ting the sound-insulating properties of building elements.It is designed to measure the reduction in transmission of impact sound due to a floor covering in alaboratory. Others in the set include the measurement of sound isolation in buildings (Test MethodE336), the laboratory methods of measuring a
4、irborne sound transmisssion loss of building partitionssuch as walls, floor-ceiling assemblies, doors, and other space-dividing elements (Test Method E90);the laboratory measurement of impact sound transmission through floors (Test Method E492), themeasurement of impact sound transmission in buildin
5、gs (Test Method E1007), the measurement ofsound transmission through building facades and facade elements (Guide E966), and the measurementof sound transmission through a common plenum between two rooms (Test Method E1414).1. Scope1.1 This test method describes a method for the laboratorymeasurement
6、 of the effectiveness of floor coverings in reducingimpact noise from a standard tapping machine through con-crete floors. The test results are not necessarily directly relatedto the subjective evaluations of the floor coverings.1.2 This test method applies to all floor coverings, whethersingle or m
7、ulti-layered, as installed on a standard concretefloor. Multi-layered coverings may be factory-assembled orassembled at the test laboratory.1.3 The test method applies only to laboratory measure-ments. It does not apply to the measurement of the effective-ness of a floor covering in a field situatio
8、n.1.4 Laboratory AccreditationA procedure for accreditinga laboratory for performing this test method is given in MethodE492.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish app
9、ro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C634 Terminology Relating to Building and EnvironmentalAcousticsE90 Test Method for Laboratory Measurement of AirborneSound Transmission Loss of Bu
10、ilding Partitions andElementsE336 Test Method for Measurement of Airborne SoundAttenuation between Rooms in BuildingsE492 Test Method for Laboratory Measurement of ImpactSound Transmission Through Floor-Ceiling AssembliesUsing the Tapping MachineE966 Guide for Field Measurements of Airborne SoundAtt
11、enuation of Building Facades and Facade ElementsE989 Classification for Determination of Impact InsulationClass (IIC)E1007 Test Method for Field Measurement of TappingMachine Impact Sound Transmission Through Floor-Ceiling Assemblies and Associated Support StructuresE1414 Test Method for Airborne So
12、und Attenuation Be-tween Rooms Sharing a Common Ceiling Plenum2.2 ANSI Standards:S1.6 Standard Preferred Frequencies, Frequency Levels, andBand Numbers for Acoustical Measurements1This test method is under the jurisdiction ofASTM Committee E33 on Buildingand Environmental Acoustics and is the direct
13、 responsibility of SubcommitteeE33.03 on Sound Transmission.Current edition approved April 1, 2016. Published April 2016. Originallyapproved in 2001. Last previous edition approved in 2009 as E2179 03 (2009).DOI: 10.1520/E2179-03R16.2For referenced ASTM standards, visit the ASTM website, www.astm.or
14、g, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1S1.10 Pressure
15、 Calibration of Laboratory Standard PressureMicrophonesS1.11 Specification for Octave-band and Fractional-Octave-Band Analog and Digital Filters2.3 ISO Standards:ISO 717-2 Rating of Sound Insulation in Buildings and ofBuilding ElementsPart 2: Impact Sound InsulationISO 140-6 AcousticsMeasurement of
16、Sound Insulation inBuildings and of Building ElementsPart 6: LaboratoryMeasurements of Impact Sound Insulation of FloorsISO 140-8 Acoustics Measurement of Sound Insulation inBuildings and of Building ElementsPart 8: LaboratoryMeasurements of the Reduction of Transmitted ImpactNoise by Floor Covering
17、s on a Heavyweight Floor3. Terminology3.1 Definitions of the acoustical terms used in this testmethod are given in Terminology C634.3.2 Definitions of Terms Specific to This Standard:3.2.1 floor coveringany resilient material, combination ofresilient materials or combination of resilient material an
18、d rigidmaterials used to provide a finished walking surface on a floor.This includes all materials between the upper walking surfaceand the base concrete slab.3.2.2 reference concrete floora hypothetical concrete floorused to calculate changes in impact insulation class (IIC).3.2.3 standard concrete
19、 floorthe actual concrete floorsatisfying the provisions of this method used in the measure-ments.4. Summary of Test Method4.1 Two vertically adjacent rooms are used: the upper onebeing designated the source room and the lower one thereceiving room. A standard concrete floor is installed in anopenin
20、g between them. The rooms and the floor installation aredesigned so the only significant sound radiation into thereceiving room is from the standard concrete floor.4.2 Astandard tapping machine is installed and activated onthe standard concrete floor and the normalized impact soundpressure levels ar
21、e measured in the room below. The floorcovering to be evaluated is then installed on the standardconcrete floor and the normalized impact sound pressure levelsmeasured again.4.3 The differences in normalized impact sound pressurelevel are subtracted from the levels defined for a referenceconcrete fl
22、oor and an IIC rating is calculated for the resultantarray. This is the IIC that the covering would produce incombination with the reference concrete floor. The secondrating, IIC, is obtained by subtracting 28 from the first (28 isthe IIC for the reference concrete floor). This gives theimprovement
23、in IIC that the covering would produce on thereference concrete floor.5. Significance and Use5.1 The impact sound rating for a floor assembly is deter-mined both by the basic floor assembly and the floor coveringon the upper surface. The same floor covering in combinationwith different basic floor a
24、ssemblies will not always give thesame impact insulation class (IIC) ratings. This test method isdesigned to provide data that characterize the floor coveringalone when installed over concrete slab floors.5.2 The IIC rating calculated in 13.4 is used to comparethe effectiveness of different floor co
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME217920032016STANDARDTESTMETHODFORLABORATORYMEASUREMENTOFTHEEFFECTIVENESSOFFLOORCOVERINGSINREDUCINGIMPACTSOUNDTRANSMISSIONTHROUGHCONCRETEFLOORS

链接地址:http://www.mydoc123.com/p-530487.html