ASTM E1979-2017 Standard Practice for Ultrasonic Extraction of Paint Dust Soil and Air Samples for Subsequent Determination of Lead《事后铅测定用涂料 灰尘 土壤和空气试样的超声波提取规程》.pdf
《ASTM E1979-2017 Standard Practice for Ultrasonic Extraction of Paint Dust Soil and Air Samples for Subsequent Determination of Lead《事后铅测定用涂料 灰尘 土壤和空气试样的超声波提取规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM E1979-2017 Standard Practice for Ultrasonic Extraction of Paint Dust Soil and Air Samples for Subsequent Determination of Lead《事后铅测定用涂料 灰尘 土壤和空气试样的超声波提取规程》.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E1979 17Standard Practice forUltrasonic Extraction of Paint, Dust, Soil, and Air Samplesfor Subsequent Determination of Lead1This standard is issued under the fixed designation E1979; the number immediately following the designation indicates the year oforiginal adoption or, in the case
2、 of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers an ultrasonic extraction procedurefor the extraction of lead from envir
3、onmental samples ofinterest in lead abatement and renovation (or related) work, foranalytical purposes.1.2 Environmental matrices of concern include dry paintfilms, settled dusts, soils, and air particulates.1.3 Samples subjected to ultrasonic extraction are preparedfor subsequent determination of l
4、ead by laboratory analyticalmethods.1.4 This practice includes, where applicable, descriptions ofprocedures for sample homogenization and weighing prior toultrasonic extraction.1.5 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard
5、.1.6 This practice does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this practice to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitation prior to use.2. Referenced D
6、ocuments2.1 ASTM Standards:2D1193 Specification for Reagent WaterD5438 Practice for Collection of Floor Dust for ChemicalAnalysisD6785 Test Method for Determination of Lead in WorkplaceAir Using Flame or Graphite Furnace Atomic AbsorptionSpectrometryD7144 Practice for Collection of Surface Dust by M
7、icro-vacuum Sampling for Subsequent Metals DeterminationE631 Terminology of Building ConstructionsE1605 Terminology Relating to Lead in BuildingsE1613 Test Method for Determination of Lead by Induc-tively Coupled Plasma Atomic Emission Spectrometry(ICP-AES), Flame Atomic Absorption Spectrometry(FAAS
8、), or Graphite Furnace Atomic Absorption Spec-trometry (GFAAS) TechniquesE1726 Practice for Preparation of Soil Samples by HotplateDigestion for Subsequent Lead AnalysisE1727 Practice for Field Collection of Soil Samples forSubsequent Lead DeterminationE1728 Practice for Collection of Settled Dust S
9、amples UsingWipe Sampling Methods for Subsequent Lead Determi-nationE1729 Practice for Field Collection of Dried Paint Samplesfor Subsequent Lead DeterminationE1775 Guide for Evaluating Performance of On-Site Extrac-tion and Field-Portable Electrochemical or Spectrophoto-metric Analysis for LeadE179
10、2 Specification for Wipe Sampling Materials for Leadin Surface Dust3. Terminology3.1 Definitions: For definitions of terms relating to thispractice that do not appear in this section, refer to Terminolo-gies E631 and E1605.3.1.1 extractionthe dissolution of target analytes from asolid matrix into a
11、liquid form.3.1.1.1 DiscussionDuring sample digestion or extraction,target analytes are extracted (solubilized) into solution toenable subsequent determination by analytical techniques (forexample, see Test Method E1613).3.1.2 ultrasonic extractionthe use of ultrasonic energyand acidic or basic solu
12、tion to extract targeted analytes fromsamples.3.1.2.1 DiscussionThe extract solution is subsequentlyanalyzed for the determination of targeted analytes.4. Summary of Practice4.1 Samples of paint, settled dust (wipe or vacuum), soil, orairborne particles, obtained by ASTM sample collection meth-ods (
13、see Practice E1729; Practice E1728, Practice D5438 and1This practice is under the jurisdiction of ASTM Committee E06 on Perfor-mance of Buildings and is the direct responsibility of Subcommittee E06.23 on LeadHazards Associated with Buildings.Current edition approved March 1, 2017. Published March 2
14、017. Formerly PS8797. Originally adopted by Committee E06 in 1998. Last previous editionapproved in 2016 as E1979-12(2016). DOI: 10.1520/E1979-17.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards
15、 volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on
16、standardization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.1Practice D7144; Practice E1727, respectively), are subjected toultrasonic extraction
17、 in dilute nitric acid for a delineated timeperiod.4.2 Paint samples are ground, homogenized and weighed, ifnecessary, prior to ultrasonic extraction.4.3 Soil and bulk dust vacuum samples are sieved,homogenized, and weighed prior to ultrasonic extraction.4.4 If applicable, dust filter samples are we
18、ighed prior toultrasonic extraction.4.5 Sample extracts are diluted with ASTM Type I water(see Specification D1193) in preparation for subsequent deter-mination of lead by analytical techniques (for example TestMethod E1613, Guide E1775, and NIOSH methods 7082,7105, and 7300 (1)3).4.6 This practice
19、was developed based on an EPA standardoperating procedure (ultrasonic extraction followed by colori-metric lead analysis (2) and published protocols (ultrasonicextraction followed by anodic stripping voltammetric determi-nation of lead) (3)(4).5. Significance and Use5.1 Ultrasonic extraction using d
20、ilute nitric acid is a simplerand easier method for extracting lead from environmentalsamples than are traditional digestion methods that employ hotplate or microwave digestion with concentrated acids (1), (3),(5), (6). Hence, ultrasonic extraction may be used in lieu of themore rigorous strong acid
21、/high temperature digestion methods(for example, see Ref (1) and Test Method E1613), providedthat the performance is demonstrated using accepted criteria asdelineated in Guide E1775.5.2 In contrast with hot plate or microwave digestiontechniques, ultrasonic extraction is field-portable, which allows
22、for on-site sample analysis.6. Apparatus and Materials6.1 Sonicator, 50 W minimum power; proper operation ofthe sonicator shall be confirmed prior to initial use andperiodically thereafter.6.2 Plastic Centrifuge Tubes, 50 mL, with screw caps.6.3 Analytical Balance, accuracy better than or equal to60
23、.002 g.6.4 Mortar and Pestle, pug mill, or wigglebug.6.5 Dry Ice (CO2(s).6.6 Cooler, for storage of dry ice.6.7 Plastic or Glass Rods, 0.6 to 1.0 cm diameter,15 to 20 cm length; tapered at one end to conform to the shapeof the bottoms of the 50 mL centrifuge tubes.6.8 Powderless Plastic Gloves.6.9 T
24、weezers.6.10 Class A Pipets, 5 or 10 mL or both, and other volumesas needed.NOTE 1Precision digital mechanical pipettors using replaceable tipsmeet Class A requirements.6.11 Laboratory Wipes, wet or dry, or both.6.12 Power Source for Sonicator.6.13 Sieves, Number 10 (1.9 mm) and 250 m.6.14 Collectio
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME19792017STANDARDPRACTICEFORULTRASONICEXTRACTIONOFPAINTDUSTSOILANDAIRSAMPLESFORSUBSEQUENTDETERMINATIONOFLEAD

链接地址:http://www.mydoc123.com/p-529973.html