ASTM E1757-2001(2015) Standard Practice for Preparation of Biomass for Compositional Analysis《成分分析用生物质制备的标准实施规程》.pdf
《ASTM E1757-2001(2015) Standard Practice for Preparation of Biomass for Compositional Analysis《成分分析用生物质制备的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM E1757-2001(2015) Standard Practice for Preparation of Biomass for Compositional Analysis《成分分析用生物质制备的标准实施规程》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E1757 01 (Reapproved 2015)Standard Practice forPreparation of Biomass for Compositional Analysis1This standard is issued under the fixed designation E1757; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of la
2、st revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers a reproducible way to converthardwoods, softwoods, herbaceous materials (such as switch-grass and s
3、ericea), agricultural residues (such as corn stover,wheat straw, and bagasse), wastepaper (such as office waste,boxboard, and newsprint), feedstocks pretreated to improvesuitability for fermentation and fermentation residues into auniform material suitable for compositional analysis.1.2 Milling and
4、sieving actions both produce large amountsof dust. This dust can be a nuisance hazard and irritant. Useappropriate respiratory protection as needed. If excessiveamounts of dust are allowed to become airborne a potentialexplosion hazard is possible. Provide appropriate dust controlmeasures as needed.
5、1.3 The values stated in SI units are to be regarded as thestandard. The inch-pound units given in parentheses are forinformation only.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to est
6、ablish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E11 Specification for Woven Wire Test Sieve Cloth and TestSieves3. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 am
7、bient conditionsa temperature of 20 to 30C (68to 85F), less than 50 % relative humidity.3.1.2 prepared biomassbiomass that has been preparedaccording to this practice.4. Significance and Use4.1 Preparation Method AMethod suitable for the prepa-ration of large quantities (20 g) of field collected sam
8、ples intoa form appropriate for compositional analysis. Woody samplesmust first be available as chips of a nominal 5 by 5 by 0.6 cm(2 by 2 by14 in.) or less and twigs not exceeding 0.6 cm (14in.) diameter. Herbaceous materials may be processed as wholestraw. It is recommended that wastepaper should
9、be shreddedinto pieces less then 1 cm (12 in.) wide. Furthermore, it isrecommended that twigs, straw and wastepaper should notexceed 61 cm (24 in.) in length to facilitate handling.4.2 Preparation Methods B and CTest methods are suit-able for very moist feedstocks, samples that would not bestable du
10、ring prolonged exposure to ambient conditions, or fordrying materials when room conditions deviate from theambient conditions described in 3.1.1. These test methods arealso suitable for handling small samples of biomass (20 g, and the intermediate model, with 1-mm screen, is suitablefor samples 20 g
11、)of biomass as described in 4.1.6.2 The raw biomass material should be spread out on asuitable surface to air dry prior to any milling. Do not pile thematerial deeper then 15 cm. Turn the material at least daily toensure even drying and minimize molding of material that maycontain significant amount
12、s of moisture. The material isconsidered dried when the change in weight is less than 1 % in24 h.6.3 The air-dried material is fed into the knife-mill and ismilled to pass througha2mmscreen in the bottom of the mill.Milled wastepaper does not need to be sieved and can be useddirectly for composition
13、 analysis. Milled biomass materialsshould be sieved as follows.6.4 The sieving is set up by stacking the sieves in thefollowing order, starting at the bottom: start with the bottompan, next stack the 80 mesh sieve, followed by the 20 meshsieve. Milled material is placed no more then 7 cm deep in the
14、20 mesh sieve.6.5 Place the cover on the sieve stack and secure the stackin the sieve shaker.6.6 The sieves need to be shaken for 15 6 1 min.At the endof the time period remove the sieves. The fraction retained onthe 20 mesh sieve (+20 mesh fraction) should be reprocessedbeginning at step 6.3. The f
15、raction retained on the 80 meshsieve (20/+80 mesh fraction) should be retained for compo-sitional analysis. The material in the bottom pan is the fines(80 mesh). Retain this material for ash analysis.6.7 Repeat 6.3 6.6 until all of the milled material will passthrough the 20 mesh sieve. If necessary
16、, combine all of the-20/+80 mesh batches. If necessary, combine all of -80 meshbatches. Weigh the combined 20/+80 mesh fraction and thecombined fines to the nearest 0.1 g. Record the 20/+80 meshfraction weight as Wt20/80and the fines fraction weight as Wt80.6.8 If multiple sieved samples were combin
17、ed they must beuniformly blended back together into a single sample. Pour the20/+80 mesh fraction into the riffle sampler, and then recom-bine the two subdivided samples in the bottom pans backtogether. Repeat this division and recombination an additionalthree times. To correctly use the riffle samp
18、ler, the sample mustbe poured evenly onto all the riffle openings at the same time.A pan, as wide as the riffle opening, should be used. Pour thesample evenly off the entire side of the pan and not from theend or the corner, nor from a container such as a jar.6.9 If the total sample needs to be subd
19、ivided into smallersamples, use the riffler at this time to divide the main sample.6.10 If the prepared sample is not analyzed immediatelyafter sieving and riffling, the sample should be stored in anair-tight container or sealable polyethylene bag and kept at20C until needed.7. Report: Preparation M
20、ethod A7.1 Calculate the percent of each fraction in the original,whole biomass:fraction20/80,%5 Wt20/803100%!/Wt20/801Wt80! (1)where:Wt20/80= weight of 20/+80 mesh fraction, g, andWt80= weight of fines fraction, g.fraction80,%5 100%2fraction20/80% (2)7.2 The mass fraction is used to weigh analytica
21、l resultswhen the two fractions differ in composition, but the results areto be reported on the original, whole biomass.8. Procedure: Preparation Method B8.1 This test method is suitable for very wet biomass that isat risk for mold growth during drying, for wet pretreatedbiomass or fermentation resi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME175720012015STANDARDPRACTICEFORPREPARATIONOFBIOMASSFORCOMPOSITIONALANALYSIS 成分 分析 生物 制备 标准 实施 规程

链接地址:http://www.mydoc123.com/p-529401.html