ASTM E1482-2012(2017) Standard Practice for Use of Gel Filtration Columns for Cytotoxicity Reduction and Neutralization《用于细胞毒性减少和中和的凝胶过滤柱的标准实施规程》.pdf
《ASTM E1482-2012(2017) Standard Practice for Use of Gel Filtration Columns for Cytotoxicity Reduction and Neutralization《用于细胞毒性减少和中和的凝胶过滤柱的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM E1482-2012(2017) Standard Practice for Use of Gel Filtration Columns for Cytotoxicity Reduction and Neutralization《用于细胞毒性减少和中和的凝胶过滤柱的标准实施规程》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E1482 12 (Reapproved 2017)Standard Practice forUse of Gel Filtration Columns for Cytotoxicity Reductionand Neutralization1This standard is issued under the fixed designation E1482; the number immediately following the designation indicates the year oforiginal adoption or, in the case of
2、 revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. ScopeNOTE 1The title was formerly Standard Test Method for Neutraliza-tion of Virucidal Agents in Viruci
3、dal Efficacy Evaluations.1.1 This practice is intended to be used to reduce thecytotoxic level of the virus-test product mixture prior toassaying for viral infectivity. It is used in conjunction withevaluations of the virucidal efficacy of disinfectant solutions,wipes, trigger sprays, or pressurized
4、 disinfectant spray prod-ucts intended for use on inanimate, nonporous environmentalsurfaces. This practice may also be used in the evaluation ofhygienic handwashes/handrubs, or for other special applica-tions. The practice may be employed with all viruses and hostsystems.1.2 This practice should be
5、 performed only by personstrained in virology techniques.1.3 This practice utilizes gel filtration technology. Theeffectiveness of the practice is dependent on the ratio of gel bedvolume to sample size and uniformity in the preparation ofcolumns as well as the conditions of entrifugation. Theeffecti
6、veness of this practice is maximized by investigatorpractice and experience with gel filtration techniques.1.4 This practice will aid in the reduction, but not necessar-ily elimination, of test product toxicity while preserving thetiter of the input virus.1.5 The values stated in SI units are to be
7、regarded asstandard. No other units of measurement are included in thisstandard.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety, health, and environmental p
8、ractices and deter-mine the applicability of regulatory limitations prior to use.1.7 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards, Guides
9、 and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2E1052 Test Method to Assess the Activity of Microbicidesagainst Viruses in SuspensionE1053 Test Method to Assess Virucidal Activity of Chemi-cals Intende
10、d for Disinfection of Inanimate, NonporousEnvironmental Surfaces3. Summary of Test Methods3.1 After the exposure of a virus to a test product (orhandwash/rub product), the virus-product suspension is addedto a column of Sephadex3LH-60, Sephadex3LH-20, orSephacryl3S-1000 Superfine. The column (encase
11、d within asterile centrifuge tube in order to capture the filtrate) is placedin a centrifuge and centrifuged to separate the virus from thetest product by gel filtration. Alternatively, samples may behand-plunged using a syringe plunger. The filtrate (the columnflow-through which contains the virus)
12、 is assayed in theappropriate host system. The untreated virus control suspen-sion is gel-column filtered, using the same methods/techniques,and the virus titer of the filtrate is determined by assay ofinfectivity. The residual cytotoxicity of the disinfectant isdetermined by gel filtration of the t
13、est product control under thesame conditions as those which were used in the test. Resultsfor the virus inactivation and test product cytotoxicity ofgel-column filtrates are recorded in the same manner asdescribed in Test Methods E1052 and E1053. The gel-column1This practice is under the jurisdictio
14、n of ASTM Committee E35 on Pesticides,Antimicrobials, and Alternative Control Agentsand is the direct responsibility ofSubcommittee E35.15 on Antimicrobial Agents.Current edition approved Nov. 1, 2017. Published December 2017. Originallyapproved in 1992. Last previous edition approved in 2012 as E14
15、82 12. DOI:10.1520/E1482-12R17.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Sephadex is a registered trad
16、emark of Amersham Biosciences. The sole sourceof supply of the apparatus known to the committee at this time is AmershamBiosciences. If you are aware of alternative suppliers, please provide this informa-tion to ASTM International Headquarters. Your comments will receive carefulconsideration at a me
17、eting of the responsible technical committee,1which you mayattend.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on standardization est
18、ablished in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.1filtration procedures described in this practice are a modifica-tion of the method of Blackwell and Che
19、n.4NOTE 2A limitation of utilizing columns in virological assays is thatthey are unable to effectively neutralize all actives. Prior to testing, ensurethe effectiveness of gel-filtration columns with the intended productchemistry. In addition, chemical neutralization is recommended to ensure/aid neu
20、tralization of certain difficult to neutralize product active(s) inaddition to the use of Sephadex columns.4. Significance and Use4.1 This practice is to be used for the removal of virucidalagents from test product-virus mixtures, or from test product-neutralizer-virus mixtures, at or after the cont
21、act period andbefore the inoculation of these mixtures into host systems forassay of viral infectivity.4.2 The purpose of the practice is to reduce the concentra-tion of the cytotoxic properties of the test product andneutralizers in order to permit the evaluation of viral infectivityat dilutions th
22、at would otherwise be toxic to the host cells.4.3 The practice is applicable to the testing of liquid,pre-saturated towelettes, and pressurized disinfectant products,as well as handwash/rub products.NOTE 3When testing handwash/rub products, the ability of thesolution to pass through the column must
23、be verified prior to testing.Certain products with high viscosities are unable to pass through columns.If the product is determined to be too viscous, alternative neutralizationmethods should be employed.4.4 This practice is compatible with organic soil loads, hardwater, disinfectants containing org
24、anic solvents, and chemicalneutralizers.5. Reagents and Materials5.1 Reagents:5.1.1 Purity of ReagentsReagent grade chemicals shall beused in all tests. Unless otherwise indicated, it is intended thatall reagents shall conform to the specifications of the Commit-tee on Analytical Reagents of the Ame
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME148220122017STANDARDPRACTICEFORUSEOFGELFILTRATIONCOLUMNSFORCYTOTOXICITYREDUCTIONANDNEUTRALIZATION

链接地址:http://www.mydoc123.com/p-528780.html