ASTM E1349-2006(2013) Standard Test Method for Reflectance Factor and Color by Spectrophotometry Using Bidirectional (45° 0° or 0° 45° ) Geometry《用双向 (45度 0度 或者0度 45度) .pdf
《ASTM E1349-2006(2013) Standard Test Method for Reflectance Factor and Color by Spectrophotometry Using Bidirectional (45° 0° or 0° 45° ) Geometry《用双向 (45度 0度 或者0度 45度) .pdf》由会员分享,可在线阅读,更多相关《ASTM E1349-2006(2013) Standard Test Method for Reflectance Factor and Color by Spectrophotometry Using Bidirectional (45° 0° or 0° 45° ) Geometry《用双向 (45度 0度 或者0度 45度) .pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E1349 06 (Reapproved 2013)Standard Test Method forReflectance Factor and Color by Spectrophotometry UsingBidirectional (45:0 or 0:45) Geometry1This standard is issued under the fixed designation E1349; the number immediately following the designation indicates the year oforiginal adopti
2、on or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the instrumental measurementof the reflection prop
3、erties and color of object-color specimensby use of a spectrophotometer or spectrocolorimeter with abidirectional optical measuring system, such as annular,circumferential, or uniplanar 45:0 or 0:45 geometry.1.2 This test method is generally suitable for any non-fluorescent, flat object-color specim
4、en. It is especially recom-mended for measuring retroreflective specimens and specimensof intermediate gloss.1.3 Procedures required for the measurement of fluorescentobject color are given in Practice E991 and Practice E2153.1.4 Procedures required for the measurement of color usingfilter colorimet
5、ers are contained in Test Method E1347 and thisstandard does not address those instruments.1.5 . This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health prac
6、tices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D2244 Practice for Calculation of Color Tolerances andColor Differences from Instrumentally Measured ColorCoordinatesE179 Guide for Selection of Geometric Conditions forMeasuremen
7、t of Reflection and Transmission Propertiesof MaterialsE284 Terminology of AppearanceE308 Practice for Computing the Colors of Objects by Usingthe CIE SystemE694 Specification for Laboratory Glass Volumetric Appa-ratusE805 Practice for Identification of Instrumental Methods ofColor or Color-Differen
8、ce Measurement of MaterialsE991 Practice for Color Measurement of Fluorescent Speci-mens Using the One-Monochromator MethodE1164 Practice for Obtaining Spectrometric Data for Object-Color EvaluationE1345 Practice for Reducing the Effect of Variability ofColor Measurement by Use of Multiple Measureme
9、ntsE1347 Test Method for Color and Color-Difference Mea-surement by Tristimulus ColorimetryE1767 Practice for Specifying the Geometries of Observa-tion and Measurement to Characterize the Appearance ofMaterialsE2153 Practice for Obtaining Bispectral Photometric Datafor Evaluation of Fluorescent Colo
10、rE2214 Practice for Specifying and Verifying the Perfor-mance of Color-Measuring Instruments3. Terminology3.1 Definitions:3.1.1 The definitions contained in Guide E179, TerminologyE284, Practice E1164, Practice E1767, and Practice E2214 areapplicable to this test method.4. Summary of Test Method4.1
11、This test method provides a procedure for measuring thereflectance factors of reflecting object-color specimens byusing a spectrophotometer or spectrocolorimeter equipped witha bidirectional optical measuring system.4.2 When the specimens exhibit directionality, and an in-strument with uniplanar geo
12、metry is used, information ondirectionality may be obtained by measuring the specimens atmore than one rotation angle, typically at two angles 90 apartas described in Practice E1345. When such information is notrequired, these measurements may be averaged, or an instru-ment with annular or circumfer
13、ential geometry may be used.However, even with annular or circumferential influx or effluxoptics, some of the variability induced by specimen opticalsystem interactions may remain and the application of themethods in Practice E1345 may help to further reduce thosemeasurement errors.1This test method
14、 is under the jurisdiction of ASTM Committee E12 on Colorand Appearance and is the direct responsibility of Subcommittee E12.02 onSpectrophotometry and Colorimetry.Current edition approved Jan. 1, 2013. Published January 2013. Originallyapproved in 1990. Last previous edition approved in 2006 as E13
15、49 06. DOI:10.1520/E1349-06R13.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International,
16、100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States14.3 This test method includes procedures for standardizingthe instrument or verifying its standardization, and for select-ing specimens suitable for precision measurement.4.4 Most modern spectrometers have the capaci
17、ty to com-pute the color coordinates of the specimen immediately fol-lowing the measurement. When this is the case, the user mustpreselect the color system, observer, and illuminant (seePractice E308, Procedure section).5. Significance and Use5.1 The most direct and accessible methods for obtainingt
18、he color coordinates of object colors are by instrumentalmeasurement using spectrophotometers or spectrocolorimeterswith either hemispherical or bidirectional optical measuringsystems. This test method provides procedures for such mea-surement by spectrophotometry using a bidirectional (0:45 or45:0)
19、 optical measuring system. The method for color andcolor difference measurement using filter colorimeters is con-tained in Test Method E1347.5.2 This test method is especially suitable for measurementof the following types of specimens for the indicated uses (seealso Guide E179 and Practice E805):5.
20、2.1 Object-color specimens of any gloss level for colorassessment.5.2.2 Object-color specimens with physically flat, smoothsurfaces from which to obtain data for use in computer colorantformulation.5.2.3 Retroreflective specimens.NOTE 1To ensure inter-instrument agreement in the measurement ofspecim
21、ens with intermediate gloss, for formulation, or of retroreflectivespecimens, significantly tighter tolerances than those given in PracticeE1164, Influx and Efflux Conditions, 45:Normal (45:0) and Normal:45(0:45) Reflectance Factor section, may be required for the instrumentangles of illumination an
22、d viewing. Information on the required tolerancesis being developed.5.3 This test method is not recommended for measurementof specimens with bare metal surfaces for color assessment, forwhich the use of hemispherical measurement geometry, as withan integrating-sphere type instrument, is preferable (
23、see GuideE179).6. Apparatus6.1 Spectrophotometer or Spectrocolorimeter, designed forthe measurement of color coordinates of reflecting specimensby use of 45:0 or 0:45 geometry with annular, circumferential,or uniplanar illumination or viewing.6.2 Standardization Materials, either supplied by the ins
24、tru-ment manufacturer or obtained separately, as follows: (SeePractice E1164, Standardization and Materials Standards sec-tion.)6.2.1 White Standard of Bidirectional Reflectance Factor(mandatory)(A standard of hemispherical reflectance factoris not suitable and should not be used.)6.2.2 Standardizat
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME134920062013STANDARDTESTMETHODFORREFLECTANCEFACTORANDCOLORBYSPECTROPHOTOMETRYUSINGBIDIRECTIONAL45DEG0DEGOR0DEG45DEGGEOMETRY

链接地址:http://www.mydoc123.com/p-528494.html