ASTM E1348-2011 Standard Test Method for Transmittance and Color by Spectrophotometry Using Hemispherical Geometry《使用半球形几何学的透射比和颜色的分光光度标准试验方法》.pdf
《ASTM E1348-2011 Standard Test Method for Transmittance and Color by Spectrophotometry Using Hemispherical Geometry《使用半球形几何学的透射比和颜色的分光光度标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E1348-2011 Standard Test Method for Transmittance and Color by Spectrophotometry Using Hemispherical Geometry《使用半球形几何学的透射比和颜色的分光光度标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E1348 11Standard Test Method forTransmittance and Color by Spectrophotometry UsingHemispherical Geometry1This standard is issued under the fixed designation E1348; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the ye
2、ar of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method describes the instrumental measure-ment of the transmission properties and color of object-colo
3、rspecimens by the use of a spectrophotometer or spectrocolo-rimeter with a hemispherical optical measuring system, such asan integrating sphere.1.2 This test method is generally suitable for all fullytransparent specimens without regard for the specimen positionrelative to the transmission port of t
4、he instrument. Translucentspecimens, however, must be placed flush against the trans-mission port of the sphere.1.3 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.4 This standard does not purport to address all of thesafety c
5、oncerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D1003 Test Method for Haze and Lumin
6、ous Transmittanceof Transparent PlasticsD2244 Practice for Calculation of Color Tolerances andColor Differences from Instrumentally Measured ColorCoordinatesE179 Guide for Selection of Geometric Conditions forMeasurement of Reflection and Transmission Properties ofMaterialsE284 Terminology of Appear
7、anceE308 Practice for Computing the Colors of Objects byUsing the CIE SystemE805 Practice for Identification of Instrumental Methods ofColor or Color-Difference Measurement of MaterialsE1164 Practice for Obtaining Spectrometric Data forObject-Color Evaluation3. Terminology3.1 Definitions:3.1.1 The d
8、efinitions in Guide E179, Terminology E284,and Practice E1164 are applicable to this test method.4. Summary of Test Method4.1 This test method provides a procedure for measuring thetransmittance of transmitting specimens by using a spectropho-tometer or spectrocolorimeter equipped with a hemispheric
9、aloptical measuring system such as an integrating sphere.4.2 This test method includes procedures for calibrating theinstrument and for selecting specimens suitable for precisionmeasurement.4.3 This test method is satisfactory for all fully transparentspecimens with plane and parallel surfaces. When
10、 possible, theuser should select the position of the specimen in the trans-mission compartment to provide either essentially total oressentially regular transmittance, depending on the end use ofthe measured data.4.4 Accurate measurement of translucent specimens re-quires that the specimen be placed
11、 flush against the transmis-sion port of the integrating sphere (see Practice E1164, 8.1.4).4.5 Most modern spectrophotometers have the capacity tocompute the color coordinates of the specimen during themeasurement. When this is the case, the user of this testmethod must select the color system, obs
12、erver, and illuminant(see the Procedure section in Practice E308, Section 6).5. Significance and Use5.1 The most direct and accessible methods for obtainingthe color coordinates of object colors are by instrumentalmeasurement using spectrophotometers or colorimeters with1This test method is under th
13、e jurisdiction of ASTM Committee E12 on Colorand Appearance and is the direct responsibility of Subcommittee E12.02 onSpectrophotometry and Colorimetry.Current edition approved Nov. 1, 2011. Published December 2011. Originallyapproved in 1990. Last previous edition approved in 2007 as E1348 - 02 (20
14、07).DOI: 10.1520/E134811.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 B
15、arr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.either hemispherical or bidirectional optical measuring sys-tems. This test method provides procedures for such measure-ment by transmittance spectrophotometry using a hemispheri-cal optical measuring system.5.2 This test
16、 method is especially suitable for measurementof the following types of specimens (see also Guide E179 andPractice E805):5.2.1 Fully transparent specimens (free from turbidity, haze,or translucency), and5.2.2 Translucent or hazy specimens, provided that thespecimen can be placed flush against the tr
17、ansmission port ofthe integrating sphere.5.3 This test method is not recommended for measurementof retroreflective transparent or translucent specimens, orsamples that are fluorescent.6. Apparatus6.1 Spectrophotometer or Spectrocolorimeter, designed forthe measurement of color coordinates of transmi
18、tting speci-mens by use of integrating-sphere geometry.6.2 Calibration Standards, either supplied by the instrumentmanufacturer or obtained separately, as follows (see PracticeE1164, Section 10):6.2.1 White Tile or Pressed-Powder Reflectance Standard,to be placed at the reflection port of the integr
19、ating sphere(mandatory).6.2.2 Calibration Standards, for (1) setting or verifying zeroon the photometric scale; (2) verifying the wavelength scale,and (3) evaluating stray light (optional).6.2.3 Verification Standards (recommended) (see PracticeE1164, 10.5).7. Test Specimen7.1 For highest precision
20、and accuracy, select specimenswith the following properties (see Practice E1164, Section 9):7.1.1 High material uniformity and freedom from blemishesin the area to be measured, and7.1.2 Specimens that have two essentially plane and parallelsurfaces, and that have a standard thickness, if one is defi
21、ned.8. Calibration and Verification8.1 Calibrate or verify the calibration of the followingquantities (see Practice E1164, Section 10):8.1.1 Zero setting of the transmittance scale (mandatory),8.1.2 Wavelength scale (recommended), and8.1.3 Stray-light level (optional).8.2 Calibrate the full-scale va
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME13482011STANDARDTESTMETHODFORTRANSMITTANCEANDCOLORBYSPECTROPHOTOMETRYUSINGHEMISPHERICALGEOMETRY

链接地址:http://www.mydoc123.com/p-528490.html