ASTM E1346-2016 Standard Practice for Bulk Sampling Handling and Preparing Edible Vegetable Oils for Sensory Evaluation《为作感官评价而对食用植物油进行大量取样 搬运和制备的标准实施规程》.pdf
《ASTM E1346-2016 Standard Practice for Bulk Sampling Handling and Preparing Edible Vegetable Oils for Sensory Evaluation《为作感官评价而对食用植物油进行大量取样 搬运和制备的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM E1346-2016 Standard Practice for Bulk Sampling Handling and Preparing Edible Vegetable Oils for Sensory Evaluation《为作感官评价而对食用植物油进行大量取样 搬运和制备的标准实施规程》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E1346 90 (Reapproved 2010)E1346 16Standard Practice forBulk Sampling, Handling, and Preparing Edible VegetableOils for Sensory Evaluation1This standard is issued under the fixed designation E1346; the number immediately following the designation indicates the year oforiginal adoption or
2、, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers the recommended procedures for bulk sampling, handling, an
3、d preparing edible vegetable oil (liquidat room temperature) prior to sensory evaluation.1.2 This practice is consistent with the background information presented in ASTM STP 433, ASTM STP 434,Manual 26, andASTM STP 758. These should be consulted for supplemental guidance.1.3 The values stated in SI
4、 units are to be regarded as standard. The values given in parentheses are for information only.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health p
5、ractices and determine the applicability of regulatorylimitations prior to use.2. Referenced Documents2.1 ASTM Publications:2ASTM STP 433 Basic Principles of Sensory EvaluationASTM STP 434Manual 26 Manual on Sensory Testing MethodsMethods, 2nd Ed.ASTM STP 758 Guidelines for the Selection and Trainin
6、g of Sensory Panel Members2.2 AOCS Standard:3Method C1-47C1-47 Sampling3. Summary of Practice3.1 This practice consists of the following basic steps: removing oil from bulk source, transporting and startingstoring oil priorto evaluation, preparing oils for evaluation, presenting samples to panel, an
7、d cleaning glassware.4. Significance and Use4.1 This practice is designed for use by the oil processor or research laboratory for evaluation by a trained sensory panel, orfor use by quality control (QC) and quality assurance (QA) personnel for sampling from a tank truck, car, or any other bulktransp
8、ortation container, or by both.4.2 The consistent use of this practice will provide representative samples for all sensory, chemical and physical analyses andwill protect the oil from oxidation.4.3 The objective of this practice is to ensure that the sample is representative of the sample source fro
9、m the time of samplinguntil the time of evaluation and to protect oil quality during that time.4.4 This practice addresses neither evaluation and scaling techniques, nor the sampling, handling, and preparing of solid fats.5. Apparatus5.1 Liquid Zone Sampler, or core sampler, or trier.4,5.2 Wide-Mout
10、h Jars,Jars made of polyethylene terephthalate, 0.5 to 1.0 L.1 This practice is under the jurisdiction of ASTM Committee E18 on Sensory Evaluationand is the direct responsibility of Subcommittee E18.06 on Food and BeverageEvaluation.Current edition approved Aug. 15, 2010Aug. 1, 2016. Published Decem
11、ber 2010August 2016. Originally approved in 1990. Last previous edition approved in 20062010as E1346 90 (2006).(2010). DOI: 10.1520/E1346-90R10.10.1520/E1346-16.2 Available from ASTM International Headquarters, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959.3 Available from Ame
12、rican Oil Chemists Society, P.O. Box 3989, Champaign, IL 61826.4 Available from Zone Devices, Inc., San Rafael, CA.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may no
13、t be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor D
14、rive, PO Box C700, West Conshohocken, PA 19428-2959. United States15.3 Amber Glass Bottles, 250 mL to 1 L, with narrow-mouth tops that will withstand freezer temperatures.5.4 Plastic Caps with polytetrafluoroethylene (PTFE) Liners, or tape (PTFE pipe thread tape), to cover top of bottle openingbefor
15、e capping with new non-metallic screw type caps. Tape should be 2.5 cm in width or wider to completely cover bottleopenings.5.5 Glass Funnels.5.6 Glove Box with inert gas nitrogen (for example, nitrogen) atmosphere, including an oxygen scavenging device.5.7 Glass Vial, 50 mL. Use amber glass for odo
16、r and flavor evaluationevaluation; and clear glass for visual examination of oil.5.8 Standard Disposable Glass Pipets, 10 mL, one per each sample.5.9 Circulating Waterbath, Water bath, with automatic timer, thermostat and rack.5.10 Waterbath Water bath Thermometer, with range from 20 to 100C in 1C d
17、ivisions, calibrated for 76 mm immersion, 305mm long.6. Precautions6.1 Oil submitted for chemical and physical testing and for sensory evaluation should be from the same bulk sampling. Tanktrucks, cars, or any other bulk transportation containers may be filled with as many as seven layers and each l
18、evel of oil may beslightly different in quality. Oil samples should be handled in the same manner and time frame to ensure high data correlation.6.2 Do not expose oil to any environmental condition (for example, light, heat, oxygen, moisture) or any equipment (metals)that will cause oxidation of the
19、 oil and alter sensory characteristics of the oil.6.3 Use only new, clean, dry, and odor-free polyethylene terephthalate wide-mouth jars to collect oil samples; dispose of jarsrather than cleaning them.6.4 Flush bottles with nitrogen in a glove box prior to filling the bottle.6.2 Obtain a representa
20、tive oil sample for all evaluations (sensory, chemical, instrumental); unblended multiple samples mayproduce different results.6.3 Do not allow glass containers in processing or production areas where oil sampling is done. Use new plastic containers suchas polyethylene terephthalate bottles for init
21、ial sampling. Flush empty bottle with nitrogen as described in 6.4.6.4 Transfer oil from plastic bottle to recommended glass bottles within one hour of collection and flush headspace withnitrogen to minimize potential transfer of odors or flavors from the plastic container to the oil (conduct proced
22、ure in glove boxunder nitrogen atmosphere).Use only new, clean, dry, and odor-free polyethylene terephthalate (PET) wide-mouth jars to collectoil samples; dispose of jars rather than cleaning them.6.8 Use PFTE-lined caps or PFTE tape under caps to protect oil from off-odors or flavors imparted from
23、metallic or unlinedplastic caps.6.5 Store oil in amber glass bottles to protect the oil from light oxidation.6.6 Choose size of storage bottle based on purpose of evaluation, amount of oil required for each testing session or for numberof panelists, and amount of oil needed for instrumental or chemi
24、cal tests. For example, a 1 L sample of oil that requires evaluationquarterly should be stored in four 250-mL bottles.6.7 Use PTFE-lined caps or PTFE tape under caps to protect oil from off-odors or flavors imparted from metallic or unlinedplastic caps.6.8 Do not expose oil to any environmental cond
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME13462016STANDARDPRACTICEFORBULKSAMPLINGHANDLINGANDPREPARINGEDIBLEVEGETABLEOILSFORSENSORYEVALUATION

链接地址:http://www.mydoc123.com/p-528485.html