ASTM E1222-1990(2009) Standard Test Method for Laboratory Measurement of the Insertion Loss of Pipe Lagging Systems《管子护套装置介入损耗的实验室测量的标准试验方法》.pdf
《ASTM E1222-1990(2009) Standard Test Method for Laboratory Measurement of the Insertion Loss of Pipe Lagging Systems《管子护套装置介入损耗的实验室测量的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E1222-1990(2009) Standard Test Method for Laboratory Measurement of the Insertion Loss of Pipe Lagging Systems《管子护套装置介入损耗的实验室测量的标准试验方法》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 1222 90 (Reapproved 2009)Standard Test Method forLaboratory Measurement of the Insertion Loss of PipeLagging Systems1This standard is issued under the fixed designation E 1222; the number immediately following the designation indicates the year oforiginal adoption or, in the case of r
2、evision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the measurement of the inser-tion loss of pipe lagging systems under labo
3、ratory conditions.1.2 A procedure for accrediting a laboratory for purposes ofthis test method is given in Annex A1.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate
4、 safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C 423 Test Method for Sound Absorption and Sound Ab-sorption Coefficients by the Reverberation Room MethodC 634 Terminology Relating to Building and Environ
5、men-tal AcousticsE90 Test Method for Laboratory Measurement of AirborneSound Transmission Loss of Building Partitions and Ele-mentsE 548 Guide for General Criteria Used for EvaluatingLaboratory Competence32.2 ANSI Standards:S1.4 Specification for Sound Level Meters4S1.6 Preferred Frequencies and Ban
6、d Numbers for Acous-tical Measurements4S1.11 Specification for Octave Band and Fractional-Octave-Band Analog and Digital Filters43. Terminology3.1 DefinitionsThe acoustical terms used in this testmethod are consistent with Terminology C 634.3.2 Definitions of Terms Specific to This Standard:3.2.1 pi
7、pe lagging systeman arrangement of noise insu-lating materials used to cover a pipe to reduce noise radiatingfrom it.4. Summary of Test Method4.1 Noise is produced inside a steel pipe located within areverberation room using band-limited white noise as a testsignal. The noise must be produced by a l
8、oudspeaker oracoustic driver located at one end of the pipe. Average soundpressure levels are measured within the reverberation room fortwo conditions, one with sound radiating from the bare pipeand the other with the same pipe covered with a laggingsystem. The insertion loss of the lagging system i
9、s thedifference in the sound pressure levels measured with soundradiating from the bare and lagged pipe, with an adjustment forchanges in room absorption due to the presence of the laggingsystem. The results may be obtained in a series of 100-Hz widebands or in one-third octave bands from 500 to 500
10、0 Hz. Using100-Hz wide bands will improve the signal-to-noise ratio in thereverberant room. This is frequently necessary when measur-ing specimens having high insertion loss.5. Significance and Use5.1 The insertion loss of a pipe lagging system dependsupon the lagging system materials, the method us
11、ed to applythe materials, the pipe wall thickness, the size and shape of thebare and lagged pipe, and the mechanisms causing noiseradiation from the pipe. Insertion losses measured using thistest method should be used with some caution. In the labora-tory, measurements must be made under reproducibl
12、e condi-tions, but in practical usage in the field, the conditions thatdetermine the effective insertion loss are difficult to predict and1This test method is under the jurisdiction ofASTM Committee E33 on Buildingand Environmental Acoustics and is the direct responsibility of SubcommitteeE33.08 on
13、Mechanical and Electrical System Noise.Current edition approved April 1, 2009. Published August 2009. Originallyapproved in 1990. Last previous edition approved in 2002 as E 1222 90 (2002).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at servic
14、eastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Withdrawn. The last approved version of this historical standard is referencedon www.astm.org.4Available from American National Standards Institute (ANSI), 25 W. 43rd St.,
15、4th Floor, New York, NY 10036, http:/www.ansi.org1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.they may lead to slightly different results. Insertion lossesmeasured with this test method can be used successfully foracoustical desig
16、n purposes. Insertion losses measured with thistest method are most useful for pipes and lagging systemswhich are similar to those used in the laboratory configuration.5.2 This test method may be used to rank-order pipe laggingsystems according to insertion loss or to estimate the fieldinsertion los
17、s of pipe lagging systems installed in the field.5.3 This test method assumes that pipe wall stresses result-ing from different methods of supporting the test pipe in thelaboratory do not have a significant effect upon the measuredinsertion loss.5.4 Pipe lagging systems typically have small insertio
18、n loss,and sometimes negative insertion loss, at frequencies below500 Hz. The results obtained at frequencies below 500 Hz maybe somewhat erratic. Sound sources used with this test methodnormally have a low frequency limit in the range from 300 to500 Hz. For these reasons, the lowest band of frequen
19、cies forwhich results are required is centered at 500 Hz.6. Interferences6.1 Flanking transmission may limit the maximum insertionlosses which can be reliably measured using this test method.The test pipe and reverberation room shall be constructed andarranged so as to minimize the possibility of tr
20、ansmission bypaths other than through the test specimen. Flanking transmis-sion should be at least 10 dB lower than the power transmittedthrough the test specimen into the reverberation room. Appen-dix X1 presents one procedure for assessing flanking transmis-sion.6.2 The background noise in each te
21、st band must be at least10 dB below measured sound pressure levels for that band.7. Apparatus7.1 Reverberation RoomThe sound field in the reverbera-tion room shall approximate a diffuse field when the testspecimen is in place. The requirements for the reverberationroom are in Test Method C 423. The
22、volume of the test roomshall be 2000 ft3or greater.7.1.1 The average sound absorption coefficients of theroom, excluding sound absorption by air and the test specimen,measured in accordance with Test Method C 423, shall be lessthan 0.06 over the test frequency range when the test specimenis in place
23、.7.1.2 Diffusing devices such as rotating and stationarydiffusing surfaces are useful for creating an adequate diffusesound field.7.2 Pipe:7.2.1 ConstructionThe standard test pipe shall be at least13 ft long and mounted horizontally within the reverberationroom. It shall be a nominal 12-in. diameter
24、 carbon steel pipewith a nominal wall thickness of14 in.7.2.2 Other pipes may be used but they shall have a wallthickness of at least14 in., a nominal diameter of at least 6 in.,and shall be at least 13 diameters long.7.2.3 InstallationPotential flanking transmission can beminimized if both ends of
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME122219902009STANDARDTESTMETHODFORLABORATORYMEASUREMENTOFTHEINSERTIONLOSSOFPIPELAGGINGSYSTEMS 管子

链接地址:http://www.mydoc123.com/p-528205.html