ASTM E394-2000(2004) Standard Test Method for Iron in Trace Quantities Using the 1 10-Phenanthroline Method《用1 10-菲咯啉法测定痕量铁值的标准试验方法》.pdf
《ASTM E394-2000(2004) Standard Test Method for Iron in Trace Quantities Using the 1 10-Phenanthroline Method《用1 10-菲咯啉法测定痕量铁值的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E394-2000(2004) Standard Test Method for Iron in Trace Quantities Using the 1 10-Phenanthroline Method《用1 10-菲咯啉法测定痕量铁值的标准试验方法》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 394 00 (Reapproved 2004)Standard Test Method forIron in Trace Quantities Using the 1,10-PhenanthrolineMethod1This standard is issued under the fixed designation E 394; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision,
2、the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of iron in therange from 1 to 100 g.1.2 This test method is int
3、ended to be general for the finalsteps in the determination of iron and does not includeprocedures for sample preparation.1.3 This test method is applicable to samples whose solu-tions have a pH less than 2. It is assumed that the pH isadjusted to within this range in the sample preparation.1.4 Revi
4、ew the current material safety data sheets (MSDS)for detailed information concerning toxicity, first-aid proce-dures, handling, and safety precautions.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this
5、 standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:D 1193 Specification for Reagent Water2E 60 Practice for Photometric and SpectrophotometricMethods for Chemical Analysis o
6、f MetalsE 180 Practice for Determining the Precision of ASTMMethods for Analysis and Testing of Industrial and Spe-cialty ChemicalsE 200 Practice for Preparation, Standardization, and Stor-age of Standard and Reagent Solutions for ChemicalAnalysisE 275 Practice for Describing and Measuring Performan
7、ceof Ultraviolet, Visible, and Near Infrared Spectrophotom-eters3. Summary of Test Method3.1 This test method is based upon a photometric determi-nation of the 1,10-phenanthroline complex with the iron(II)ion. The sample is dissolved in a suitable solvent and the ironis reduced to the divalent state
8、 by the addition of hydroxy-lamine hydrochloride. The color is then developed, by theaddition of 1,10-phenanthroline. After a short reaction period,the absorbance of the solution is measured at approximately510 nm using a suitable photometer. The absorbance of thesolution, once the color is develope
9、d, is stable for at leastseveral months.4. Significance and Use4.1 This test method is suitable for determining traceconcentrations of iron in a wide variety of products, providedthat appropriate sample preparation has rendered the iron andsample matrix soluble in water or other suitable solvent (se
10、e10.1 and Note 6).4.2 This test method assumes that the amount of colordeveloped is proportional to the amount of iron in the testsolution. The calibration curve is linear over the specifiedrange. Possible interferences are described in Section 5.5. Interferences5.1 Fortune and Mellon3have made a co
11、mprehensive studyof the interferences of various inorganic ions in this determi-nation. Table 1 and Table 2, taken from their report, show theeffects of various cations and anions on the determination of2.0 ppm iron. If the maximum level of 500 ppm does notinterfere, it is very likely that the ion w
12、ill not interfere in anyquantity. The data were obtained under slightly differentconditions than those specified in the present test method, butthe interferences should be similar. For a more detaileddescription of interferences, the original literature should beconsulted.5.2 Aldehydes, ketones, and
13、 oxidizing agents interfere byconsuming the hydroxylamine hydrochloride added as a reduc-ing agent.1This test method is under the jurisdiction of ASTM Committee E15 onIndustrial and Specialty Chemicals and is the direct responsibility of SubcommitteeE15.01 on General StandardsCurrent edition approve
14、d Oct. 1, 2004. Published November 2004. Originallyapproved in 1970. Last previous edition approved in 2000 as E 394 00.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer
15、 to the standards Document Summary page onthe ASTM website.3Fortune, W. B., and Mellon, M. G., Industrial and Engineering Chemistry,Analytical Edition, IENAA Vol 10, 1938, pp. 6064.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.6. A
16、pparatus6.1 Photometer, capable of measuring light absorption at510 nm and holding a 5-cm or 1-cm cell. Check the perfor-mance of the photometer at regular intervals according to theguidelines given in Practice E 275 and the manufacturersmanual.NOTE 1If a filter photometer is used, a narrow band fil
17、ter having itsmaximum transmission at 480 to 520 nm should be used. A discussion ofphotometers and photometric practice is given in Practice E60.6.2 Absorption Cells, 5-cm or 1-cm light path.7. Reagents and Materials7.1 Purity of ReagentsUnless otherwise indicated, it isintended that all reagents sh
18、all conform to the specifications ofTABLE 1 Effect of Cations on the Determination of 2 ppm IronIon Added AsMaximum Added WithoutInterference, ppmApplicable pH RangeAluminum AlCl3500 2.03.0Ammonium NH4Cl 500 2.09.0Antimony SbCl330 3.09.0Arsenic As2O5500 3.09.0Arsenic As2O3500 3.09.0Barium BaCl2500 3
19、.09.0Beryllium Be(NO3)2500 3.05.5Bismuth Bi(NO3)3.A.ACadmium Cd(NO3)250 3.09.0Calcium Ca(NO3)2500 2.09.0Chromium Cr2(SO4)320 2.09.0Cobalt Co(NO3)210 3.05.0Copper Cu(NO3)210 2.54.0Lead Pb(C2H3O2)2500 2.09.0Lithium LiCl 500 2.09.0Magnesium Mg(NO3)2500 2.09.0Manganese MnSO4500 2.09.0Mercury HgCl21 2.09
20、.0Mercury Hg2(NO3)210 3.29.0Molybdenum (NH4)6Mo7O24100 5.59.0Nickel Ni(NO3)22 2.59.0Potassium KCl 1000 2.09.0Silver AgNO3.A.ASodium NaCl 1000 2.09.0Strontium Sr(NO3)2500 2.09.0Thorium Th(NO3)4250 2.09.0Tin H2SnCl620 3.06.0Tin H2SnCl410 2.06.0Tungsten Na2WO410 2.59.0Uranium UO2(C2H3O2)2100 2.06.0Zinc
21、 Zn(NO3)210 2.09.0Zirconium Zr(NO3)450 2.09.0AMust be completely absent because of precipitation.TABLE 2 Effect of Anions on the Determination of 2 ppm IronIon Added AsMaximum Added WithoutInterference, ppmApplicable pH RangeAcetate NaC2H3O2500 2.09.0Tetraborate Na2B4O7500 3.09.0Bromide NaBr 500 2.0
22、9.0Carbonate Na2CO3500 3.09.0Chlorate KClO3500 2.59.0Chloride NaCl 1000 2.09.0Citrate H3C6H5O7500 2.09.0Cyanide KCN 10 2.09.0Dichromate K2Cr2O720 2.59.0Fluoride NaF 500 4.09.0Iodide KI 500 2.09.0Nitrate KNO3500 2.09.0Nitrite KNO2500 2.59.0Oxalate (NH4)2C2O4500 6.09.0Perchlorate KClO4100 2.09.0Phosph
23、ate (NH4)2HPO420 2.09.0Pyrophosphate Na4P2O750 6.09.0Silicate Na2SiO3100 2.04.5Sulfate (NH4)2SO4500 2.09.0Sulfite Na2SO3500 2.09.0Tartrate (NH4)2C4H9O6500 3.09.0Thiocyanate KCNS 500 2.09.0Thiosulfate Na2S2O3500 3.09.0E 394 00 (2004)2the Committee onAnalytical Reagents of theAmerican Chemi-cal Societ
24、y, where such specifications are available.4Othergrades may be used, provided it is first ascertained that thereagent is of sufficiently high purity to permit its use withoutlessening the accuracy of the determination.7.2 Purity of WaterUnless otherwise indicated, referencesto water shall be underst
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便