ASTM D8002-2015e1 8877 Standard Test Method for Modified Fouling Index (MFI-0 45) of Water《水分修正污染指数 (MFI-0 45) 的标准试验方法》.pdf
《ASTM D8002-2015e1 8877 Standard Test Method for Modified Fouling Index (MFI-0 45) of Water《水分修正污染指数 (MFI-0 45) 的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D8002-2015e1 8877 Standard Test Method for Modified Fouling Index (MFI-0 45) of Water《水分修正污染指数 (MFI-0 45) 的标准试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D8002 151Standard Test Method forModified Fouling Index (MFI-0.45) of Water1This standard is issued under the fixed designation D8002; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number
2、 in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTENote 12 was editorially corrected in June 2016.1. Scope1.1 This test method covers the determination of the modi-fied fouling index (MFI) of water m
3、easured at constantpressure. This test can be used to indicate the fouling potentialof reverse osmosis/nanofiltration (RO/NF) feed water dueparticulate matter and is applicable to low and high turbiditywaters. Since the size, shape, and nature of particulate matter inwater may vary, this test method
4、 is not an absolute measure-ment of the quantity of particulate matter.1.2 This test method is not applicable for reagent-gradewater Types I, II, and III of Specification D1193 or effluentsfrom most reverse osmosis and ultra-filtration systems.1.3 The values stated in SI units are to be regarded ass
5、tandard. No other units of measurement are included in thisstandard.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the a
6、pplica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D1129 Terminology Relating to WaterD1193 Specification for Reagent WaterD2777 Practice for Determination of Precision and Bias ofApplicable Test Methods of Committee D19 on WaterD3370 Practices for Sampli
7、ng Water from Closed ConduitsD4189 Test Method for Silt Density Index (SDI) of WaterD6161 Terminology Used for Microfiltration, Ultrafiltration,Nanofiltration and Reverse Osmosis Membrane ProcessesD7726 Guide for The Use of Various Turbidimeter Tech-nologies for Measurement of Turbidity in Water3. T
8、erminology3.1 Definitions:3.1.1 For definitions of terms used in this standard, refer toTerminologies D1129 and D6161.3.2 Definitions of Terms Specific to This Standard:3.2.1 modified fouling index, MFI-0.45, nindex calculatedfrom the development of filtration velocity through a 0.45-mmembrane filte
9、r. D27774. Summary of Test Method4.1 Water is passed through a 0.45-m membrane filter atconstant pressure of 200 kPa and the development of the rateof filtration is measured continuously.4.2 The MFI is calculated from the obtained data of flowversus time at constant pressure and temperature.5. Signi
10、ficance and Use5.1 This test method is an alternative for the silt densityindex (SDI) method (Test Method D4189) with the aim toovercome inaccuracies related to a nonlinear relation with thefouling potential due to particulate matter concentration, ab-sence of temperature correction, support pad, an
11、d time.5.2 The MFI-0.45 can serve as a useful indication of thequantity of particulate matter.5.3 The MFI-0.45 can be used to determine effectiveness ofvarious processes such as filtration or clarification used toremove particulate matter.5.4 The MFI-0.45 has empirically been correlated withfouling
12、tendency of some water treatment equipment such asreverse osmosis (RO) devices.6. Apparatus6.1 MFI AssemblyAs described in Fig. 1 and Fig. 2,wetted parts should be made of high-quality stainless or plasticto prevent contamination by corrosion products. Do not usereactive materials such as carbon ste
13、el, galvanized steel, castiron, and copper alloys. Suitable filter holders, designed towithstand an operational gage pressure of 350 kPa, can be1This test method is under the jurisdiction of ASTM Committee D19 on Waterand is the direct responsibility of Subcommittee D19.08 on Membranes and IonExchan
14、ge Materials.Current edition approved July 15, 2015. Published August 2015. DOI: 10.1520/D8002-15E01.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards D
15、ocument Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1obtained from suppliers of membrane filters. The filter holdershould be equipped with a device releasing air.6.2 Membrane Filter:6.2.1 Membrane, w
16、hite hydrophilic, mixed cellulose nitrate(5075 %) and mixed cellulose acetate (MCE).6.2.2 Replaceable Highly Porous Foam Support Pad, to beplaced on the bottom of the filter holder.6.2.3 Mean Pore Size, 0.45 m.6.2.4 Diameter, 47 mm.6.2.5 Thickness, 115 to 180 m.6.2.6 Pure Water Flow, 25 to 50 s/500
17、mL.6.2.7 Pressure Difference across Membrane Filter, 200 kPa.6.2.8 Bubble Point, 179 to 248 kPa.6.2.9 Use only filters that are packaged in the same orien-tation.6.3 Thermometer or Sensor Suitable for Measuring Tem-perature of the Water Sample, capable of being read orregistered 61C.6.4 Electronic f
18、low meter or mass balance.6.5 Computer or data-collecting and processing device.7. Procedure7.1 Assemble apparatus as shown in Fig. 1 and Fig. 2including flow-measuring devices (electronic flow meter ormass balance) and set the pressure regulator at 200 kPa.NOTE 1PI is pressure indicator; PC is pres
19、sure controller.FIG. 1 Apparatus for Measuring MFI at Constant Pressure with a PumpFIG. 2 Representative Apparatus for Measuring MFI at Constant Pressure with a Pressure VesselD8002 15127.2 Before installing the membrane filter, flush the water tobe tested through the apparatus to remove contaminant
20、s. Forsampling, follow the procedure given in Practices D3370.Discrete samples can be used with appropriate pressurizingapparatus such as a pump or an air/nitrogen pressurized vessel.NOTE 1The pump should be of such a design that grinding flocs willnot occur or be minimal.NOTE 2Ensure that the sampl
21、e to be tested is not super saturated withair or nitrogen.7.3 Measure the temperature of the water.7.4 Open the membrane filter holder and place a 0.45-mmembrane filter (47 mm in diameter) on the support plate ofthe holder. A replaceable foam support pad needs to be placedon the support plate of the
22、 holder. Handle the membrane filteronly with dull tweezers to avoid puncturing. Avoid touchingthe membrane filter with fingers.NOTE 3Record the manufacturer of the membrane filter and manu-facturers identification for the membrane filter.7.5 Make sure the O-ring is in good condition and properlyplac
23、ed.7.6 Replace the top of the half of the filter holder and closeloosely.7.7 Bleed out air by opening the pressure relieve valve andopen the small air relieve valve on top of the filter holder.NOTE 4Apparatus making use of membranes of smaller diametersmight use a disposable membrane incorporated in
24、 a filter holder. Thesedisposables should be equipped with an air relieve device.7.8 Close the relieve valve and start recording flow (andpreferably pressure as well). Run the test for 30 to 60 mindepending on the rate of flow decline.NOTE 5The initial flow should be within 10 % of the flow recorded
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD80022015E18877STANDARDTESTMETHODFORMODIFIEDFOULINGINDEXMFI045OFWATER 水分 修正 污染 指数 MFI045 标准 试验 方法

链接地址:http://www.mydoc123.com/p-526621.html