ASTM D7840-2012 4428 Standard Test Method for Foaming Tendencies of Non-Aqueous Engine Coolants in Glassware《在玻璃器皿中发动机冷却剂起泡倾向的试验方法》.pdf
《ASTM D7840-2012 4428 Standard Test Method for Foaming Tendencies of Non-Aqueous Engine Coolants in Glassware《在玻璃器皿中发动机冷却剂起泡倾向的试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D7840-2012 4428 Standard Test Method for Foaming Tendencies of Non-Aqueous Engine Coolants in Glassware《在玻璃器皿中发动机冷却剂起泡倾向的试验方法》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D7840 12Standard Test Method forFoaming Tendencies of Non-Aqueous Engine Coolants inGlassware1This standard is issued under the fixed designation D7840; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last
2、revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers a simple glassware test forevaluating the tendency of non-aqueous engine coolants tofoam under labo
3、ratory controlled conditions of aeration andtemperature.1.2 UnitsThe values stated in SI units are to be regardedas the standard. No other units of measurement are included inthis standard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is
4、 theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. For specificwarning statements, see 7.2 and 7.3.2. Referenced Documents2.1 ASTM Standards:2D1193 Specification for Reagent Wa
5、terE1 Specification for ASTM Liquid-in-Glass ThermometersE128 Test Method for Maximum Pore Diameter and Perme-ability of Rigid Porous Filters for Laboratory UseE230 Specification and Temperature-Electromotive Force(EMF) Tables for Standardized Thermocouples3. Terminology3.1 Definitions of Terms Spec
6、ific to This Standard:3.1.1 break time, ntime required for the foam to collapse(after the air supply has been shut off) to the first appearance ofan “eye” on the surface of the test solution.3.1.2 eye, nappearance of foam-free area on the surface ofthe test coolant surrounded by a ring of foam cling
7、ing to thecylinder walls.4. Summary of Test Method4.1 The non-aqueous coolant of interest is blown with air ata constant rate for 5 min while maintained at a constanttemperature of 88 6 1C by means of a suitable temperaturebath. The volume of foam and the time for such foam to breakare measured.5. S
8、ignificance and Use5.1 In the test method, coolants generally will be distin-guished that have a tendency to foam excessively from thosethat are suitable for further evaluation to determine perfor-mance in actual service.NOTE 1In use, the foaming tendency of a coolant solution may beincreased by ser
9、vice aging or contamination. A properly functioningpressure cap will tend to suppress foaming in coolant solutions.6. Apparatus6.1 Container, a 500-mL graduated container of heat-resistant glass having a diameter of 45 to 50 mm and a lengthof 380 mm.6.2 Temperature Bath, a heat-resistant glass conta
10、iner largeenough to permit immersion of the graduated container at leastto the 350-mL graduation mark. A 4000-mL beaker is satisfac-tory.6.3 Heat Source, any heating system capable of maintaininga uniform bath temperature of 61C. A 750-W electric hotplate is satisfactory.6.4 Aerator Tube, a 25.4-mm
11、diameter spherical gas-diffuser stone3made of fused crystalline alumina grain thatmeets the following specifications when tested in accordancewith the method given in Annex A1:Maximum pore diameter, m Not greater than 80Permeability at a pressure of 2.45 kPa,mL of air/min3000 to 64006.5 Temperature
12、Measuring Instrument (EnvironmentallySafe Thermometer or Thermocouple)An ASTM Partial Im-mersion Temperature Measuring Instrument having a rangefrom 20 to 150C (0 to 302F) and conforming to the1This test method is under the jurisdiction of ASTM Committee D15 on EngineCoolants and Related Fluids and
13、is the direct responsibility of SubcommitteeD15.22 on Non-Aqueous Coolants.Current edition approved Dec. 1, 2012. Published January 2013. DOI: 10.1520/D7840-12.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of
14、 ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3For information on aerator supplier and specifications, contact ASTM Subcom-mittee D15.06 through ASTM International Headquarters.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West
15、 Conshohocken, PA 19428-2959. United States1requirements for Thermometer 1C (1F), as prescribed inSpecification E1 or Thermocouple as summarized in Specifi-cation E230.6.6 Air Supply, a clean and dry source, free from grease andother contaminants, capable of maintaining the prescribed flowrate throu
16、gh the diffuser stone.6.7 Timer, a stop watch or suitable timing device accurate to60.2 s.6.8 Vent, a three-way stopcock inserted in the metered airsupply line immediately ahead of the aerator tube.6.9 Typical Assembly Setup, A typical apparatus using ahot-plate heat source is shown in Fig. 1.7. Rea
17、gents and Materials7.1 Purity of WaterUnless otherwise indicated, referencesto water means reagent water as defined by Type II ofSpecification D1193.7.2 Acetone, for flushing and drying the test equipment.(WarningAcetone is extremely flammable.)7.3 Cleaning BathRefers to an acid or base cleaningsolu
18、tion used to clean glassware between tests. The choice ofcleaning baths depends on individual needs. For example,Nochromix and alcoholic sodium (potassium) hydroxide arecommon acid and base cleaning baths, respectively.4(WarningThe cleaning baths are strong oxidants and strongacid and base, respecti
19、vely. Avoid contact with skin, eyes, andclothing. Do not breathe vapor. Handle in a fume hood.)4Nochromix is an inorganic oxidizer that contains no metallic ions. The whitepowder is dissolved in water and mixed with concentrated sulfuric acid, giving asolution that reportedly is more strongly oxidiz
20、ing than chromic acid. The solesource of supply of Nochromix known to the committee at this time is GodaxLaboratories Inc., PO box 422, Cabin John, MD 20818. If you are aware ofalternative suppliers, please provide this information to ASTM InternationalHeadquarters. Your comments will receive carefu
21、l consideration at a meeting of theresponsible technical committee, which you may attend.FIG. 1 Schematic Drawing of Apparatus for Glassware Foam TestD7840 1228. Test Coolant8.1 The non-aqueous coolant is intended to be tested as-is,without dilution or adulteration of any kind.9. Conditioning9.1 Tes
22、t TemperatureThe temperature bath shall be kept ata constant volume (350- to 375-mL mark of the graduatedcylinder) throughout the test. The reference and test coolantsshall be maintained at 88 6 1C throughout.9.2 Aeration RateThe aeration rate shall be 1000 6 25mL/min.9.3 Number of TestsThe non-aque
23、ous test coolant shall betested in triplicate using a fresh sample of the non-aqueous testcoolant from the same lot for each test. The entire containerand aerator tube (see 6.1 and 6.4) shall be cleaned scrupulouslyprior to the first test and between each subsequent test. Thesame container and aerat
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD784020124428STANDARDTESTMETHODFORFOAMINGTENDENCIESOFNONAQUEOUSENGINECOOLANTSINGLASSWARE 玻璃器皿 发动机

链接地址:http://www.mydoc123.com/p-526397.html