ASTM D7041-2004(2010) 1875 Standard Test Method for Determination of Total Sulfur in Light Hydrocarbons Motor Fuels and Oils by Online Gas Chromatography with Flame Photometric Det.pdf
《ASTM D7041-2004(2010) 1875 Standard Test Method for Determination of Total Sulfur in Light Hydrocarbons Motor Fuels and Oils by Online Gas Chromatography with Flame Photometric Det.pdf》由会员分享,可在线阅读,更多相关《ASTM D7041-2004(2010) 1875 Standard Test Method for Determination of Total Sulfur in Light Hydrocarbons Motor Fuels and Oils by Online Gas Chromatography with Flame Photometric Det.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D7041 04 (Reapproved 2010)Standard Test Method forDetermination of Total Sulfur in Light Hydrocarbons, MotorFuels, and Oils by Online Gas Chromatography with FlamePhotometric Detection1This standard is issued under the fixed designation D7041; the number immediately following the design
2、ation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the dete
3、rmination of total sulfurin liquid hydrocarbons with a final boiling point less than450C by gas chromatography using a flame photometricdetector.1.2 This test method is applicable for total sulfur levels from0.5 to 100 mg S/kg.NOTE 1The pooled limit of quantification (PLOQ) derived from the2002 inte
4、rlaboratory cooperative test program was determined to be 1mgS/kg.NOTE 2Samples can also be tested at other total sulfur levels, but theprecision statements may not apply.1.3 The values stated in SI units are to be regarded asstandard.1.4 This standard does not purport to address all of thesafety co
5、ncerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. For specific hazardstatements see Section 7.2. Referenced Documents2.1 ASTM Sta
6、ndards:2D1298 Test Method for Density, Relative Density (SpecificGravity), or API Gravity of Crude Petroleum and LiquidPetroleum Products by Hydrometer MethodD4052 Test Method for Density, Relative Density, and APIGravity of Liquids by Digital Density MeterD4057 Practice for Manual Sampling of Petro
7、leum andPetroleum ProductsD4177 Practice for Automatic Sampling of Petroleum andPetroleum ProductsE840 Practice for Using Flame Photometric Detectors inGas Chromatography3. Summary of Test Method3.1 The sample is analyzed by gas chromatography with aflame photometric detector. A fixed amount of samp
8、le isinjected into the gas chromatograph where it is vaporized. Theair carrier stream carries the vaporized sample into a hightemperature zone (900C) where the compounds present inthe sample are oxidized. Sulfur compounds are converted tosulfur dioxide (SO2). The carrier stream carries the oxidation
9、components onto a chromatographic column where they areseparated and the SO2is quantified by the flame photometricdetector. Calibration of the detector is achieved by the use of anappropriate external standard.4. Significance and Use4.1 This test method can be used to determine total sulfurlevels in
10、 process feeds and finished products that fall within thescope of this test method.4.2 Low levels of sulfur in process feed stocks can poisonexpensive catalysts used in petroleum refining processes. Thistest method can be used to monitor sulfur levels in thesefeedstocks.5. Apparatus5.1 Gas Chromatog
11、raph, equipped with automatically con-trolled valves, capable of automatic calibration with an exter-nal standard and having a flame photometric detector with anoverall sensitivity to detect at least 0.5 mg/kg of SO2. It mustbe able to automatically control all valve switching times.Although origina
12、lly developed with online analytical measure-ment equipment in an offline mode of operation, suitable onlineor laboratory gas chromatographs may apply this test methodas described. Typical instrument parameters are listed in Table1.5.1.1 Carrier and Detector Gas ControlThe chromato-graph must be equ
13、ipped with flow controllers or pressurecontrollers capable of maintaining a constant supply of carrier1This test method is under the jurisdiction of ASTM Committee D02 onPetroleum Products and Lubricants and is the direct responsibility of SubcommitteeD02.03 on Elemental Analysis.Current edition app
14、roved May 1, 2010. Published May 2010. Originallyapproved in 2004. Last previous edition approved in 2004 as D704104. DOI:10.1520/D7041-04R10.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards vol
15、ume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.gas and detector supply gases. Electronic pressure or flowcontrol is highly recommended.5.1.2 Sample Inj
16、ection SystemAn automatic sample injec-tion device is required. The injector must allow the introduc-tion of small sample sizes (0.1 to 1 L). The sample must beaccurately and repeatably injected into the gas chromatograph.Rotary or stem type liquid injection valves or auto injectors arerecommended.
17、The valve or injector must be equipped with aheated vaporizer section capable of being heated to at least285C.5.2 Pyrolysis FurnaceA furnace capable of maintaining asufficient temperature (900C) to pyrolyze the entire sampleand oxidize the sulfur compounds to SO2.5.3 Quartz Combustion TubeQuartz tub
18、e capable of with-standing temperatures up to 1200C. The oxidation sectionshall be large enough to ensure complete oxidation of thesample.5.4 ColumnA column that can provide complete separa-tion of SO2from the CO2quench and the other oxidizedcomponents such as H2O.5.5 DetectorAny flame photometric d
19、etector (FPD) canbe used, provided it can detect a minimum peak height twicethat of the baseline noise fora1Linjection of a 0.5 mg S/kgstandard. Detector linearity shall be at least equal to or greaterthan 103. The user is referred to Practice E840 for assistance inoptimizing the operation and perfo
20、rmance of the FPD.5.6 Data Acquisition SystemUse any integrator or com-puterized data acquisition system for peak area integration, aswell as for recording the chromatographic trace. The deviceand software must have the following capabilities:5.6.1 Identification of peak by retention time.5.6.2 Calc
21、ulation and use of response factors.5.6.3 External standard calibration calculation.5.6.4 Graphic presentation of the chromatogram.5.7 Analytical BalanceAny balance capable of accuratelyweighing materials to the nearest 0.01 mg.6. Reagents and Materials6.1 Purity of ReagentsReagent grade chemicals s
22、hall beused in all tests. Unless otherwise indicated, it is intended thatall reagents shall conform to the specifications of the Commit-tee on Analytical Reagents of the American Chemical Society,where such specifications are available.3Other grades may beused, provided it is first ascertained that
23、the reagent is ofsufficiently high purity to permit its use without lessening theaccuracy of the determination.6.2 Carrier-GasZero grade air is recommended.(WarningCompressed air is a gas under high pressure thatsupports combustion.)6.3 HydrogenChromatographic grade recommended,minimum purity 99.995
24、 %. (WarningHydrogen is an ex-tremely flammable gas under high pressure.)6.4 Solvent (Reagent Grade)the solvent chosen should becapable of dissolving the sulfur-containing compound used toprepare the standard. The solvent of choice should have adensity similar to the samples being analyzed and it sh
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD7041200420101875STANDARDTESTMETHODFORDETERMINATIONOFTOTALSULFURINLIGHTHYDROCARBONSMOTORFUELSANDOILSBYONLINEGASCHROMATOGRAPHYWITHFLAMEPHOTOMETRICDETPDF

链接地址:http://www.mydoc123.com/p-524340.html