《ASTM D6356 D6356M-1998(2018) 4375 Standard Test Method for Hydrogen Gas Generation of Aluminum Emulsified Asphalt Used as a Protective Coating for Roofing.pdf》由会员分享,可在线阅读,更多相关《ASTM D6356 D6356M-1998(2018) 4375 Standard Test Method for Hydrogen Gas Generation of Aluminum Emulsified Asphalt Used as a Protective Coating for Roofing.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D6356/D6356M 98 (Reapproved 2018)Standard Test Method forHydrogen Gas Generation of Aluminum Emulsified AsphaltUsed as a Protective Coating for Roofing1This standard is issued under the fixed designation D6356/D6356M; the number immediately following the designation indicates theyear of
2、 original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of lastreapproval. A superscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers a hydrogen gas and stability testf
3、or aluminum emulsified asphalt coatings.1.2 The values stated in either SI units or inch-pound unitsare to be regarded separately as standard. The values stated ineach system may not be exact equivalents; therefore, eachsystem shall be used independently of the other. Combiningvalues from the two sy
4、stems may result in non-conformancewith the standard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety, health, and environmental practices and deter-mine the
5、 applicability of regulatory limitations prior to use.1.4 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recom-mendations issue
6、d by the World Trade Organization TechnicalBarriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2D1079 Terminology Relating to Roofing and WaterproofingD2939 Test Methods for Emulsified Bitumens Used asProtective Coatings (Withdrawn 2012)3E1 Specification for ASTM Liquid-in-Gl
7、ass Thermometers3. Summary of Test Method3.1 A 200 g sample of water based aluminized coating isheated to 51.7 6 1C 125 6 2F in an Erlenmeyer flask andthe volume in millilitres of hydrogen gas evolved is measured.The test is conducted for one week (168 h) with a reading takenevery 24 h. The test roo
8、m is to be maintained at 73.4 6 3.6Fin order to standardize gas collection temperature in the buretterecepticle.4. Significance and Use4.1 This procedure measures the amount of hydrogen gasgeneration potential of aluminized emulsion roof coating.There is the possibility of water reacting with alumin
9、umpigment to generate hydrogen gas. This situation is to beavoided, so this test was designed to evaluate coating formu-lations and assess the propensity to gassing.5. Apparatus and Materials5.1 The assembly of the hydrogen gas generation testapparatus is illustrated in Fig. 1. Details of the compon
10、ent partare as follows:5.1.1 Wide Mouth Glass Erlenmeyer Flask, 250-mL capac-ity.5.1.2 Beaker, glass, 250-mL.5.1.3 Burette, standard glass 100-mL graduated with glassstopcock and 0.2 mL divisions.5.1.4 Condenser, glass jacketed, having the dimensionsshown in Fig. 2.5.1.5 Glass Tubing, standard glass
11、 6.35 mm 14 in. insidediameter 7.94 mm 516 in. outside diameter and 127 mm 5in. length for forming the J tube.5.1.6 Tubing, pure latex amber rubber tubing, 6.35 mm 14in.5.1.7 Neoprene Rubber Stopper, No. 8 with one hole (pre-ferred connection for glass condenser to 250-mL Erlenmeyerflask).5.1.8 Oil
12、or Water BathConstant temperature immersioncirculating bath capable of temperature control.5.1.9 OilCommercially available mineral oil or suitableheat transfer fluid.5.1.10 ThermometerASTM thermometer having a rangefrom 2 to + 80C 30 to 180F and conforming to therequirements for thermometer 15C or 1
13、5F as prescribed inSpecification E1.1This test method is under the jurisdiction of ASTM Committee D08 on Roofingand Waterproofing and is the direct responsibility of Subcommittee D08.09 onBituminous Emulsions.Current edition approved July 1, 2018. Published July 2018. Originally approvedin 1998. Las
14、t previous edition approved in 2011 as D6356/D6356M 98 (2011)1.DOI: 10.1520/D6356_D6356M-98R18.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Documen
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD6356D6356M199820184375STANDARDTESTMETHODFORHYDROGENGASGENERATIONOFALUMINUMEMULSIFIEDASPHALTUSEDASAPROTECTIVECOATINGFORROOFINGPDF

链接地址:http://www.mydoc123.com/p-522272.html