ASTM D6348-2003(2010) 1250 Standard Test Method for Determination of Gaseous Compounds by Extractive Direct Interface Fourier Transform Infrared (FTIR) Spectroscopy《通过可提取的直接界面傅里叶转换.pdf
《ASTM D6348-2003(2010) 1250 Standard Test Method for Determination of Gaseous Compounds by Extractive Direct Interface Fourier Transform Infrared (FTIR) Spectroscopy《通过可提取的直接界面傅里叶转换.pdf》由会员分享,可在线阅读,更多相关《ASTM D6348-2003(2010) 1250 Standard Test Method for Determination of Gaseous Compounds by Extractive Direct Interface Fourier Transform Infrared (FTIR) Spectroscopy《通过可提取的直接界面傅里叶转换.pdf(15页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D6348 03 (Reapproved 2010)Standard Test Method forDetermination of Gaseous Compounds by Extractive DirectInterface Fourier Transform Infrared (FTIR) Spectroscopy1This standard is issued under the fixed designation D6348; the number immediately following the designation indicates the yea
2、r oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.INTRODUCTIONThis extractive FTIR based field test method is used to
3、 quantify gas phase concentrations of multipletarget analytes from stationary source effluent. Because an FTIR analyzer is potentially capable ofanalyzing hundreds of compounds, this test method is not analyte or source specific. The analytes,detection levels, and data quality objectives are expecte
4、d to change for any particular testing situation.It is the responsibility of the tester to define the target analytes, the associated detection limits for thoseanalytes in the particular source effluent, and the required data quality objectives for each specific testprogram. Provisions are included
5、in this test method that require the tester to determine criticalsampling system and instrument operational parameters, and for the conduct of QA/QC procedures.Testers following this test method will generate data that will allow an independent observer to verifythe valid collection, identification,
6、 and quantification of the subject target analytes.1. Scope1.1 This field test method employs an extractive samplingsystem to direct stationary source effluent to an FTIR spec-trometer for the identification and quantification of gaseouscompounds. This test method is potentially applicable for thede
7、termination of compounds that (1) have sufficient vaporpressure to be transported to the FTIR spectrometer and (2)absorb a sufficient amount of infrared radiation to be detected.1.2 This field test method provides near real time analysis ofextracted gas samples from stationary sources. Gas streamswi
8、th high moisture content may require conditioning to mini-mize the excessive spectral absorption features imposed bywater vapor.1.3 This field test method requires the preparation of asource specific field test plan. The test plan must include thefollowing: (1) the identification of the specific tar
9、get analytes(2) the known analytical interferents specific to the test facilitysource effluent (3) the test data quality necessary to meet thespecific test requirements and (4) the results obtained from thelaboratory testing (see Annex A1 for test plan requirements).1.4 The FTIR instrument range sho
10、uld be sufficient tomeasure from high ppm(v) to ppb(v) and may be extended tohigher or lower concentrations using any or all of the followingprocedures:1.4.1 The gas absorption cell path length may be eitherincreased or decreased,1.4.2 The sample conditioning system may be modified toreduce the wate
11、r vapor, CO2, and other interfering compoundsto levels that allow for quantification of the target com-pound(s), and1.4.3 The analytical algorithm may be modified such thatinterfering absorbance bands are minimized or stronger/weakerabsorbance bands are employed for the target analytes.1.5 The pract
12、ical minimum detectable concentration is in-strument, compound, and interference specific (see Annex A2for procedures to estimate the achievable minimum detectableconcentrations (MDCs). The actual sensitivity of the FTIRmeasurement system for the individual target analytes dependsupon the following:
13、1.5.1 The specific infrared absorptivity (signal) and wave-length analysis region for each target analyte,1.5.2 The amount of instrument noise (see Annex A6), and1.5.3 The concentration of interfering compounds in thesample gas (in particular, percent moisture and CO2), and theamount of spectral ove
14、rlap imparted by these compounds in thewavelength region(s) used for the quantification of the targetanalytes.1.5.4 Any sampling system interferences such as adsorptionor outgassing.1.6 Practices E168 and E1252 are suggested for additionalreading.1.7 This standard does not purport to address all of
15、thesafety concerns associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and1This test method is under the jurisdiction of Committee D22 onAir Quality andis the direct responsibility of Subcommittee D22.03 on Ambient Atmospheres andSource Emiss
16、ions.Current edition approved Oct. 1, 2010. Published November 2010. Originallyapproved in 1998. Last previous edition approved in 2003 as D6348 - 03. DOI:10.1520/D6348-03R10.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.health pra
17、ctices and to determine the applicability of regula-tory limitations prior to use. Additional safety precautions aredescribed in Section 9.2. Referenced Documents2.1 ASTM Standards:2D1356 Terminology Relating to Sampling and Analysis ofAtmospheresD3195 Practice for Rotameter CalibrationE168 Practice
18、s for General Techniques of Infrared Quanti-tative AnalysisE1252 Practice for General Techniques for Obtaining Infra-red Spectra for Qualitative Analysis2.2 EPA Methods (40 CFR Part 60 Appendix A)3Method 1 - Sample and Velocity Traverses for StationarySourcesMethod 2 Series - Determination of Stack
19、Gas Velocity andVolumetric Flow Rate (Type S Pitot Tube)Method 3 Series - Gas Analysis for Carbon Dioxide, Oxy-gen, Excess Air, and Dry Molecular WeightMethod 4 Series - Determination of Moisture Content inStack Gases3. Terminology3.1 See Terminology D1356 for definition of terms relatedto sampling
20、and analysis of atmospheres.3.2 Definitions of Terms Specific to This StandardThissection contains the terms and definitions used in this testmethod and those that are relevant to extractive FTIR basedsampling and analysis of stationary source effluent. Whenpossible, definitions of terms have been d
21、rawn from authori-tative texts or manuscripts in the fields of air pollutionmonitoring, spectroscopy, optics, and analytical chemistry.3.2.1 absorbance, nthe negative logarithm of the trans-mission, A = -log (I/I0), where I is the transmitted intensity ofthe light and I0is the incident intensity.3.2
22、.2 absorptivity, adjthe amount of infrared radiationthat is absorbed by each molecule.3.2.3 analyte spiking, nthe process of quantitatively co-adding calibration standards with source effluent to determinethe effectiveness of the FTIR measurement system to quantifythe target analytes.3.2.4 analytica
23、l algorithm, nthe method used to quantifythe concentration of the target analytes and interferences ineach FTIR Spectrum. The analytical algorithm should accountfor the analytical interferences by conducting the analysis in aportion of the infrared spectrum that is the most unique for thatparticular
24、 compound.3.2.5 analytical interference, nthe physical effects ofsuperimposing two or more light waves. Analytical interfer-ences occur when two or more compounds have overlappingabsorbance bands in their infrared spectra.3.2.6 apodization, va mathematical transformation car-ried out on data receive
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD6348200320101250STANDARDTESTMETHODFORDETERMINATIONOFGASEOUSCOMPOUNDSBYEXTRACTIVEDIRECTINTERFACEFOURIERTRANSFORMINFRAREDFTIRSPECTROSCOPY

链接地址:http://www.mydoc123.com/p-522244.html