ASTM D6330-1998(2008) 346 Standard Practice for Determination of Volatile Organic Compounds (Excluding Formaldehyde) Emissions from Wood-Based Panels Using Small Environmental Cham.pdf
《ASTM D6330-1998(2008) 346 Standard Practice for Determination of Volatile Organic Compounds (Excluding Formaldehyde) Emissions from Wood-Based Panels Using Small Environmental Cham.pdf》由会员分享,可在线阅读,更多相关《ASTM D6330-1998(2008) 346 Standard Practice for Determination of Volatile Organic Compounds (Excluding Formaldehyde) Emissions from Wood-Based Panels Using Small Environmental Cham.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 6330 98 (Reapproved 2008)Standard Practice forDetermination of Volatile Organic Compounds (ExcludingFormaldehyde) Emissions from Wood-Based Panels UsingSmall Environmental Chambers Under Defined TestConditions1This standard is issued under the fixed designation D 6330; the number imme
2、diately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 The
3、practice measures the volatile organic compounds(VOC), excluding formaldehyde, emitted from manufacturedwood-based panels.Apre-screening analysis is used to identifythe VOCs emitted from the panel. Emission factors (that is,emission rates per unit surface area) for the VOCs of interestare then deter
4、mined by measuring the concentrations in a smallenvironmental test chamber containing a specimen. The testchamber is ventilated at a constant air change rate under thestandard environmental conditions. For formaldehyde determi-nation, see Test Method D 6007.1.2 This practice describes a test method
5、that is specific tothe measurement of VOC emissions from newly manufacturedindividual wood-based panels, such as particleboard, plywood,and oriented strand board (OSB), for the purpose of comparingthe emission characteristics of different products under thestandard test condition. For general guidan
6、ce on conductingsmall environmental chamber tests, see Guide D5116.1.3 VOC concentrations in the environmental test chamberare determined by adsorption on an appropriate single adsor-bent tube or multi-adsorbent tube, followed by thermal desorp-tion and combined gas chromatograph/mass spectrometry (
7、GC/MS) or gas chromatograph/flame ionization detection (GC/FID). The air sampling procedure and the analytical methodrecommended in this practice are generally valid for theidentification and quantification of VOCs with saturation vaporpressure between 500 and 0.01 kPa at 25C, depending on theselect
8、ion of adsorbent(s).NOTE 1VOCs being captured by an adsorbent tube depend on theadsorbent(s) and sampling procedure selected (see Practice D 6196). Theuser should have a thorough understanding of the limitations of eachadsorbent used.1.4 The emission factors determined using the above pro-cedure des
9、cribe the emission characteristics of the specimenunder the standard test condition. These data can be useddirectly to compare the emission characteristics of differentproducts and to estimate the emission rates up to one monthafter the production. They shall not be used to predict theemission rates
10、 over longer periods of time (that is, more thanone month) or under different environmental conditions.1.5 Emission data from chamber tests can be used forpredicting the impact of wood-based panels on the VOCconcentrations in buildings by using an appropriate indoor airquality model, which is beyond
11、 the scope of this practice.1.6 The values stated in SI units shall be regarded as thestandard (see IEEE/ASTM SI-10).1.7 This practice does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of the standard to consult andestablish a
12、ppropriate safety and health practices and deter-mine the applicability of regulatory limitations prior to use.For specified hazard statements see Section 6.2. Referenced Documents2.1 ASTM Standards:2D 1356 Terminology Relating to Sampling and Analysis ofAtmospheresD 1914 Practice for Conversion Uni
13、ts and Factors Relatingto Sampling and Analysis of AtmospheresD5116 Guide for Small-Scale Environmental Chamber De-terminations of Organic Emissions From Indoor Materials/ProductsD 6007 Test Method for Determining Formaldehyde Con-centrations in Air from Wood Products Using a Small-Scale ChamberD 61
14、96 Practice for Selection of Sorbents, Sampling, andThermal Desorption Analysis Procedures for Volatile Or-ganic Compounds in AirE 355 Practice for Gas Chromatography Terms and Rela-tionships1This practice is under the jurisdiction of ASTM Committee D22 on Air Qualityand is the direct responsibility
15、 of Subcommittee D22.05 on Indoor Air.Current edition approved Aug. 1, 2008. Published September 2008. Originallyapproved in 1998. Last previous edition approved in 2003 as D 6330 - 98 (2003).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at ser
16、viceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.E 741 Test Method for Determining Air Change in a Sing
17、leZone by Means of a Tracer Gas DilutionIEEE/ASTM SI-10 Standard for Use of the InternationalSystem of Units (SI): The Modern Metric System2.2 Other Standard:EPA TO-17 Determination of Volatile Organic Compoundsin Ambient Air Using Active Sampling Onto SorbentTubes, Compendium of Methods for the Det
18、ermination ofToxic Organic Compounds in Ambient Air3. Terminology3.1 DefinitionsFor definitions and terms that are com-monly used, refer to Terminology D 1356 and Practice E 355.For definitions and terms related to test methods using small-scale environmental chamber, refer to Guide D5116. For anexp
19、lanation of units, symbols, and conversion factors, refer toPractice D 1914.3.2 Definitions of Terms Specific to This Standard:3.2.1 environmental enclosurea container or space inwhich the environmental test chamber(s) is placed. The enclo-sure has controlled temperature and relative humidity.3.2.2
20、loading ratio (m2/m3)the total exposed surface areaof each test specimen divided by the net air volume of theenvironmental test chamber.3.2.3 nominal time constant (tn)the time required toobtain one air change in the environmental test chamber, whichis equal to the inverse of the air change rate.3.2
21、.4 pre-screening analysisa procedure for identifyingthe VOCs emitted from a test specimen. The results are used todetermine the appropriate GC/MS or GC/FID analyticalmethod for subsequent dynamic chamber tests.3.2.5 standard environmental test chamber conditionatest condition of temperature at 23 6
22、0.5C, relative humidity(RH) at 50 6 5 %, air change rate per hour in the chamber at1 6 0.03 ACH, and chamber loading ratio at 0.40 6 0.01m2/m3.3.2.5.1 DiscussionThe VOC emission rates for wood-based panel products are generally controlled by VOC diffu-sions within the material. The airflow condition
23、 (air velocityand turbulence) over the test specimen has minimal effect onthe emission rates; therefore, it is not specified in the standardtest condition.3.2.6 tracer gasa gaseous compound that is neither emit-ted by the wood-based panel nor present in the supply air to thechamber. It can be used t
24、o determine the mixing characteristicsof the environmental test chamber, and it provides a cross-check of the air change rate measurements.3.2.7 TVOCtotal concentration of all the individual vola-tile organic compounds (VOC) captured from air by a givensorbent, or a given combination of several sorb
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD633019982008346STANDARDPRACTICEFORDETERMINATIONOFVOLATILEORGANICCOMPOUNDSEXCLUDINGFORMALDEHYDEEMISSIONSFROMWOODBASEDPANELSUSINGSMALLENVIRONMENTALCHAMPDF

链接地址:http://www.mydoc123.com/p-522188.html