ASTM D6248-1998(2012)e1 7203 Standard Test Method for Vinyl and Trans Unsaturation in Polyethylene by Infrared Spectrophotometry《通过红外线分光光度法对聚乙烯中乙烯基和反向不饱和性的标准试验方法》.pdf
《ASTM D6248-1998(2012)e1 7203 Standard Test Method for Vinyl and Trans Unsaturation in Polyethylene by Infrared Spectrophotometry《通过红外线分光光度法对聚乙烯中乙烯基和反向不饱和性的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D6248-1998(2012)e1 7203 Standard Test Method for Vinyl and Trans Unsaturation in Polyethylene by Infrared Spectrophotometry《通过红外线分光光度法对聚乙烯中乙烯基和反向不饱和性的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D6248 98 (Reapproved 2012)1Standard Test Method forVinyl and Trans Unsaturation in Polyethylene by InfraredSpectrophotometry1This standard is issued under the fixed designation D6248; the number immediately following the designation indicates the year oforiginal adoption or, in the case
2、 of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTEReapproved with editorial changes in May 2012.1. Scope1.1 This test method covers most types of pol
3、yethylene,those ethylene plastics consisting of ethylene and a-olefincomonomers longer than propylene, and blends of the above inany ratio.1.2 The values stated in SI units are to be regarded as thestandard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated w
4、ith its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. Specific hazardsstatements are given in Section 8.NOTE 1There is no known ISO equivalent for this standard.
5、2. Referenced Documents2.1 ASTM Standards:2D792 Test Methods for Density and Specific Gravity (Rela-tive Density) of Plastics by DisplacementD1505 Test Method for Density of Plastics by the Density-Gradient TechniqueD3124 Test Method for Vinylidene Unsaturation in Poly-ethylene by Infrared Spectroph
6、otometryE131 Terminology Relating to Molecular SpectroscopyE168 Practices for General Techniques of Infrared Quanti-tative AnalysisE177 Practice for Use of the Terms Precision and Bias inASTM Test MethodsE275 Practice for Describing and Measuring Performanceof Ultraviolet and Visible Spectrophotomet
7、ers3. Terminology3.1 GeneralThe units, symbols, and abbreviations used inthis test method appear in Terminology E131.4. Summary of Test Method4.1 The band at 965 cm1is characteristic of the trans-vinylene substituted group. The band at 908 cm1is character-istic of the terminal vinyl group.4.2 These
8、bands are not seriously overlapped by interferinggroups from the polymer. The vinyl absorbance at 908 cm1isclose to the absorbance band from terminal methyl groups onchains longer than ethyl, at 895 cm1. This interference isminimal for most products. Inclusion of the bromination andspectral subtract
9、ion step from Test Method D3124 has beenfound to improve the results for some very low densityproducts.4.3 Integrated absorbance is used in this test method.Integrated absorbance is found by integrating the spectrumover the absorbance band when the spectrum is plotted asabsorbance versus frequency,
10、in cm1. Most spectral manipu-lation software contains algorithms for adequately determiningbaseline corrected integrated absorbencies.4.4 Calibration is performed using a solution of 1-octene fornormal vinyl groups, and trans-3-hexene for trans-vinylenegroups.5. Significance and Use5.1 There are thr
11、ee types of olefinic groups present insufficient concentrations to warrant consideration, one or moreof that can normally be found in any polyethylene. The threetypes are trans-vinylene, R-CH=CH-R8, sometimes referred to1This test method is under the jurisdiction of ASTM Committee D20 on Plasticsand
12、 is the direct responsibility of Subcommittee D20.70 on Analytical Methods.Current edition approved May 1, 2012. Published July 2012. Originally approvedin 1998. Last previous edition approved in 2004 as D6248 - 98 (2004). DOI:10.1520/D6248-98R12E01.2For referenced ASTM standards, visit the ASTM web
13、site, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United Sta
14、tes.as trans-internal unsaturation; vinylidene or pendent methyl-ene, RR8C-CH2; and vinyl unsaturation, R-CH=CH2, alsoreferred to as terminal unsaturation.5.2 The type and quantity of these groups can influence thechemical and physical properties of the resin. Informationconcerning their presence ca
15、n also be used to characterize oridentify unknown resins or blends of resins.5.3 Additives can interfere with unsaturation measurements.The use is cautioned to determine which additives are presentand if there any absorbance bands caused by additive presencethat overlap or interfere with unsaturatio
16、n absorbance bandsused in this test method in the range of 1050 to 850 cm1.Ifoverlapping bands occur, the method is not applicable.5.4 Interference fringes resulting from smooth sample sur-faces can cause measurement errors. This test method requiresthe use of aluminum foil in the compression moldin
17、g ofsamples to provide an adequately rough surface to minimizeinterference fringes.6. Apparatus6.1 Infrared Spectrophotometer, either double-beam, or aFourier transform (FTIR).6.1.1 Double-Beam Infrared Spectrophotometer, capable ofspectral resolution as defined in Condition C of Section III(Spectra
18、l Resolution) of the Proposed Methods for the Evalu-ation of Spectrophotometers. Also, see Practice E275 fortesting procedures. An instrument capable of scale expansionalong the wavelength (or wave number) axis is preferred.6.1.2 Fourier Transform Infrared Spectrometer, capable of4cm1resolution. The
19、 instrument should be capable of scaleexpansion along the wavelength axis.6.2 Compression Molding Press, small, with platens capableof being heated to 170 C.6.3 Two Metal Plates, 150 by 150 mm or larger, of 0.5-mmor greater thickness with smooth surfaces.6.4 Brass Shims, approximately 75 by 75 mm, o
20、f 0.5-mmthickness with an aperture in the center at least 25 by 38 mmfor most samples. A thinner shim can be used with highlyabsorbing samples.6.5 Micrometer Calipers, with thimble graduations of 0.001mm.6.6 Infrared Liquid Cell, with sodium chloride or potassiumbromide windows.6.7 Film Mounts, with
21、 apertures at least 6 by 27 mm, to holdthe specimens in the infrared spectrophotometer.7. Reagents and Materials7.1 Carbon Disulfide (CS2), reagent grade.7.2 Aluminum Foil Sheets.8. Hazards8.1 Carbon disulfide is flammable and toxic.9. Calibration9.1 Prepare at least three different solutions of eac
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD624819982012E17203STANDARDTESTMETHODFORVINYLANDTRANSUNSATURATIONINPOLYETHYLENEBYINFRAREDSPECTROPHOTOMETRY

链接地址:http://www.mydoc123.com/p-521963.html