ASTM D6246-2008(2013)e1 5258 Standard Practice for Evaluating the Performance of Diffusive Samplers《评估扩散取样器性能的标准实施规程》.pdf
《ASTM D6246-2008(2013)e1 5258 Standard Practice for Evaluating the Performance of Diffusive Samplers《评估扩散取样器性能的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM D6246-2008(2013)e1 5258 Standard Practice for Evaluating the Performance of Diffusive Samplers《评估扩散取样器性能的标准实施规程》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D6246 08 (Reapproved 2013)1Standard Practice forEvaluating the Performance of Diffusive Samplers1This standard is issued under the fixed designation D6246; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of la
2、st revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTEThe References Section was editorially corrected in July 2015.1. Scope1.1 This practice covers the evaluation of the performanc
3、eof diffusive samplers of gases and vapors for use over samplingperiods from 4 to 12 h and for wind speeds less than 0.5 m/s.Such sampling periods and wind speeds are the most commonin the indoor workplace setting. This practice does not apply tostatic or area sampling in wind speeds less than 0.1 m
4、/s, whendiffusion outside the sampler may dominate needed convectionfrom the ambient air to the vicinity of the sampler. Given asuitable exposure chamber, the practice can be extended tocover sampler use for other sampling periods and conditions.The aim is to provide a concise set of experiments for
5、classifying samplers primarily in accordance with a singlesampler accuracy figure. Accuracy is defined (3.2.1) in thisstandard so as to take into account both imprecision anduncorrected bias. Accuracy estimates refer to conditions ofsampler use which are normally expected in a workplacesetting. Thes
6、e conditions may be characterized by thetemperature, atmospheric pressure, humidity, and ambientwind speed, none of which may be constant or accuratelyknown when the sampler is used in the field. Futhermore, theaccuracy accounts for the effects of diffusive loss of analyte onthe estimation of time-w
7、eighted averages of concentrationswhich may not be constant in time. Aside from accuracy, thesamplers are tested for compliance with the manufacturersstated limits on capacity, possibly in the presence of interferingcompounds.1.2 This practice is an extension of previous research ondiffusive sampler
8、s (1-14)2as well as Practices D4597, D4598,D4599, and MDHS 27. An essential advance here is theestimation of sampler accuracy under actual conditions of use.Futhermore, the costs of sampler evaluation are reduced.1.3 Knowledge gained from similar analytes expedites sam-pler evaluation. For example,
9、interpolation of data character-izing the sampling of analytes at separated points of ahomologous series of compounds is recommended. At presentthe procedure of (9) is suggested. Following evaluation of asampler in use at a single homologous series member accord-ing to the present practice, higher m
10、olecular weight memberswould receive partial validations considering sampling rate,capacity, analytical recovery, and interferences. The test fordiffusive analyte loss can be omitted if the effect is foundnegligible for a given sampler or analyte series.1.4 The values stated in SI units are to be re
11、garded asstandard. No other units of measurement are included in thisstandard.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and deter
12、mine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:3D1356 Terminology Relating to Sampling and Analysis ofAtmospheresD4597 Practice for Sampling Workplace Atmospheres toCollect Gases or Vapors with Solid Sorbent DiffusiveSamplersD4598 Practice fo
13、r Sampling Workplace Atmospheres toCollect Gases or Vapors with Liquid Sorbent DiffusionalSamplers (Withdrawn 1995)4D4599 Practice for Measuring the Concentration of ToxicGases or Vapors Using Length-of-Stain Dosimeters2.2 International Standards:CEN EN 838 European Standard, Workplace atmospheres -
14、Diffusive samplers for the determination of gases orvapours - Requirements and test methods51This practice is under the jurisdiction ofASTM Committee D22 on Air Qualityand is the direct responsibility of Subcommittee D22.04 on Workplace Air Quality.Current edition approved April 1, 2013. Published A
15、pril 2013. Originallyapproved in 1998. Last previous edition approved in 2008 as D6246 08. DOI:10.1520/D6246-08R13E01.2The boldface numbers in parentheses refer to the list of references at the end ofthis standard.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM C
16、ustomer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.4The last approved version of this historical standard is referenced onwww.astm.org.5Available from CEN Central Secretariat, rue de Stassart 36, B-
17、1050 Brussels,Belgium.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1MDHS 27 Protocol for assessing the performance of adiffusive sampler, Health and Safety Laboratory, UnitedKingdom6MDHS 80 Volatile organic compounds in air, Health
18、andSafety Laboratory, United Kingdom63. Terminology3.1 Definitions:3.1.1 For definitions of terms used in this practice, refer toTerminology D1356.3.2 Definitions of Terms Specific to This Standard:3.2.1 Symmetric Accuracy Range Athe fractional range,symmetric about the true concentration c, within
19、which 95 %of sampler measurements are to be found (14-19). In terms ofthe bias relative to true concentrations and the total (true)relative standard deviation RSD (sometimes designated asTRSD), the accuracy range A is closely approximated (19) by:A 5H1.960 3 =21RSD2, if ?,RSD/1.645?11.645 3RSD, othe
20、rwise(1)3.2.1.1 DiscussionIn the case that bias is corrected, leav-ing only an uncorrectable residual bias due to uncertainty in thecorrection, 95 %-confidence limits on A play the role of theexpanded uncertainty in (20). As described in (14), such aninterpretation is an extension of (20) for measur
21、ement, as inoccupational hygiene, of concentrations which are neitherspatially nor temporally constant. Rather than continuallyre-evaluating a method through estimate replicates, the accu-racy provides confidence intervals bracketing (true) concentra-tions at greater than a given probability (95 %)
22、for a fixedconfidence (95 %) in the initial sampler evaluation. Suchintervals with double confidence levels (in both measurementand evaluation) are related to a branch of statistics known asthe theory of tolerance or prediction intervals.3.2.2 diffusive samplera device which is capable of takingsamp
23、les of gases or vapors from the atmosphere at a ratecontrolled by a physical process such as gaseous diffusionthrough a static air layer or permeation through a membrane,but which does not involve the active movement of air throughthe sampler. As such, direct-reading dosimeters, as well assamplers r
24、equiring lab analysis, are considered diffusive sam-plers within this practice.3.3 Symbols:A = symmetric accuracy range as defined in terms ofbias and imprecision = estimated symmetric accuracy range AA95 %= 95 % confidence limit on the symmetric accu-racy range Ac(mg/m3) = true or reference analyte
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD624620082013E15258STANDARDPRACTICEFOREVALUATINGTHEPERFORMANCEOFDIFFUSIVESAMPLERS 评估 扩散 取样 性能 标准

链接地址:http://www.mydoc123.com/p-521959.html