1、Designation: D6226 10Standard Test Method forOpen Cell Content of Rigid Cellular Plastics1This standard is issued under the fixed designation D6226; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A numbe
2、r in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers cellular plastics, which arecomposed of membranes or walls of polymer separating smallcavities or cells. These cells
3、 may be interconnecting (opencell), non-connecting (closed cell), or any combination of thesetypes. This test method determines numerical values for opencells. It is a porosity determination, measuring the accessiblecellular volume of a material. The remaining volume is thatoccupied by closed cells
4、and cell walls. Since any convenientlysized specimen can only be obtained by some cutting opera-tion, a fraction of the closed cells will be opened by specimenpreparation and will be included as open cells, (see Note 2).1.2 This test method provides good accuracy on predomi-nantly highly open-celled
5、 materials. By not accounting forclosed cells that were opened during specimen preparation, theaccuracy decreases as the closed cell content increases and asthe cell size increases.1.3 The values as stated in SI units are to be regarded as thestandard. The values in parentheses are given for referen
6、ceonly.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.NOTE 1Th
7、is test method and ISO 4590 use the same basic principlesbut are significantly different in experimental detail.NOTE 2Two procedures for correcting for cells opened during speci-men preparation are described in Appendix X1.1.2. Referenced Documents2.1 ASTM Standards:2D883 Terminology Relating to Pla
8、sticsD2842 Test Method for Water Absorption of Rigid CellularPlasticsD3576 Test Method for Cell Size of Rigid Cellular PlasticsE691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test Method2.2 ISO Standard:ISO 4590 Cellular PlasticsDetermination of Volume Per-centag
9、e of Open and Closed Cells of Rigid Materials33. Terminology3.1 Definitions:3.1.1 Terms relating to plastics as given in TerminologyD883 shall be used where applicable.3.2 Definitions of Terms Specific to This Standard:3.2.1 closed cella cell totally enclosed by its walls andhence not interconnectin
10、g with other cells.3.2.2 open cella cell not totally enclosed by its walls andopen to the surface either directly or by interconnecting withother cells.3.2.3 volume of closed cells and cell wallsinaccessibleinternal volume, consisting of an aggregate of solid polymervolume (cell walls, struts), fill
11、er volume, when applicable(solid particles or fibers), the volume of individual closed cells,and the volume of small cell groups interconnected by rupturedcell walls but otherwise inaccessible.3.2.4 uncorrected volume of open cellsthe aggregate mea-surement of both the internal porous volume of the
12、materialand the various irregular volumes accessible at the cut-cellsurface of the test specimen.3.3 Symbols:3.3.1 dspecimen diameter, cm.3.3.2 hspecimen height, cm.3.3.3 lspecimen length, cm.3.3.4 Ovvolume, percent open cells.3.3.5 Vgeometric volume of specimen, cm3.3.3.6 VCALIBvolume of the calibr
13、ation standard, cm3.3.3.7 VCHAMBERvolume of the sample chamber, cm3.3.3.8 VEXPexpansion reference volume, cm3.3.3.9 VSPECspecimen displacement volume, cm3, and,3.3.10 wspecimen width, cm.4. Summary of Test Method4.1 This test method is based on a determination of porosityin which the accessible cell
14、ular volume of a cellular plastic is1This test method is under the jurisdiction of ASTM Committee D20 on Plasticsand is the direct responsibility of Subcommittee D20.22 on Cellular Materials -Plastics and Elastomers.Current edition approved Aug. 1, 2010. Published September 2010. Originallyapproved
15、in 1998. Last previous edition approved in 2005 as D6226 - 05. DOI:10.1520/D6226-10.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary p
16、age onthe ASTM website.3Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.determined by application of Boyles Law, which states t
17、hatthe increase in volume of a confined gas results in a propor-tionate decrease in pressure. The apparatus consists of twochambers of known volume connected by a valve. One of thechambers, the calibrated sample chamber, is accessible forinsertion of the test specimen and is connected to a source of
18、high purity (at least 99.99 %) dry gas, such as nitrogen orhelium. The pressure in the sample chamber is increased to apredetermined pressure and this value, P1, is noted. The valvebetween the two chambers is then opened and the second,lower Pressure, P2, is again noted. The ratio of the pressurecha
19、nge P1/P2, is directly related to the volume of the samplechamber displaced by the specimen. The difference betweenthis volume and the geometric volume of the specimen is ameasure of the open-cell volume.NOTE 3The criteria for selecting a dry gas are that the gas shall notexhibit significant non-ide
20、al behavior, dissolve the matrix, or readilydiffuse into the matrix.5. Significance and Use5.1 This test method is intended to be used in specificationswhere porosity of cellular plastics has a direct bearing on theirend use. For example, for thermal insulation applications, ahigh percentage of clos
21、ed cells is necessary to prevent escapeof gases and to promote low thermal conductivity. In flotationapplications, high closed-cell content generally reduces waterabsorption.5.2 Before proceeding with this test method, reference shallbe made to the specification of the material being tested. Anytest
22、 specimen preparation, conditioning, or dimensions, orboth, and testing parameters covered in the materials specifi-cation shall take precedence over those mentioned in this testmethod. If there are no material specifications, then the defaultconditions apply.6. Apparatus6.1 Gas PycnometerA schemati
23、c diagram of the pycnom-eter apparatus is shown in Fig. 1. It shall have the followingfeatures:6.1.1 Sample Chamber (VCHAMBER), having a volume ap-proximately between 30 and 150 cm3(1.8 and 9.2 in.3),calibrated to the nearest 0.1 cm3(0.006 in.3).6.1.2 Expansion Reference Volume (VEXP), a precisely c
24、ali-brated volume known to the nearest 0.1 cm3(0.006 in.3).6.1.3 Gage Pressure Transducer, capable of measuring 0 to175 kPa (0 to 25 psig) with minimum volume displacement andlinear within 0.1%.6.1.4 Pressure Relief Valve, to avoid over pressurization ofthe transducer.6.1.5 Filter, to prevent powder
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD622620104375STANDARDTESTMETHODFOROPENCELLCONTENTOFRIGIDCELLULARPLASTICS 硬质 泡沫塑料 含量 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-521900.html