1、Designation: D6142 12D6142 16Standard Test Method forAnalysis of Phenol by Capillary Gas Chromatography1This standard is issued under the fixed designation D6142; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last rev
2、ision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method covers the determination of known impurities in phenol by gas chromatography (GC). It is generally meantfor
3、the analysis of phenol of 99.9 % or greater purity.1.2 This test method has been found applicable over impurity concentrations of 15 to 70 mg/kg. Users of this method believeit is linear over a wider range.1.3 In determining the conformance of the test results using this method to applicable specifi
4、cations, results shall be roundedoff in accordance with the rounding-off method of Practice E29.1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.5 This standard does not purport to address all of the safety concerns, if a
5、ny, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use. For specific hazard statements, see Section 9.2. Referenced Documents2.1 ASTM Standards:2D3852
6、 Practice for Sampling and Handling Phenol, Cresols, and Cresylic AcidD4307 Practice for Preparation of Liquid Blends for Use as Analytical StandardsD4790 Terminology of Aromatic Hydrocarbons and Related ChemicalsD6809 Guide for Quality Control and Quality Assurance Procedures for Aromatic Hydrocarb
7、ons and Related MaterialsE29 Practice for Using Significant Digits in Test Data to Determine Conformance with SpecificationsE355 Practice for Gas Chromatography Terms and RelationshipsE691 Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test MethodE1510 Practice for
8、Installing Fused Silica Open Tubular Capillary Columns in Gas Chromatographs2.2 Other Document:OSHA Regulations, 29 CFR paragraphs 1910.1000 and 1910.120033. Terminology3.1 See Terminology D4790 for definition of terms used in this test method.4. Summary of Test Method4.1 A known amount of an intern
9、al standard is added to a sample of phenol. The prepared sample is mixed and analyzed bya gas chromatograph equipped with a flame ionization detector (FID). The peak area of each impurity and the internal standardis measured. The amount of each impurity is calculated from the ratio of the peak area
10、of the internal standard versus the peakarea of the impurity. Results are reported in milligrams per kilogram.1 This test method is under the jurisdiction of ASTM Committee D16 on Aromatic Hydrocarbons and Related Chemicals and is the direct responsibility of SubcommitteeD16.02 on Oxygenated Aromati
11、cs.Current edition approved June 1, 2012June 1, 2016. Published June 2012June 2016. Originally approved in 1997. Last previous edition approved in 20082012 as D6142 08.12. DOI: 10.1520/D6142-12.10.1520/D6142-16.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Custo
12、mer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.3 Available from U.S. Government Printing Office Superintendent of Documents, 732 N. Capitol St., NW, Mail Stop: SDE, Washington, DC 20401, http:/www.
13、access.gpo.gov.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users co
14、nsult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocke
15、n, PA 19428-2959. United States15. Significance and Use5.1 This test method is suitable for setting specifications on phenol and for use as an internal quality control tool where phenolis produced or is used in a manufacturing process. It may also be used in development or research work involving ph
16、enol. It isgenerally applied to determining those commonly occurring impurities such as mesityl oxide, cumene, hydroxyacetone, acetone,alpha-methylstyrene, 2-methylbenzofuran, and acetophenone.5.2 Purity is commonly reported by subtracting the determined expected impurities from 100.00. However, a g
17、as chromato-graphic analysis cannot determine absolute purity if water is present or unknown components are contained within the materialbeing examined.6. Interferences6.1 The internal standard chosen must be sufficiently resolved from any impurity and the phenol peak.6.2 Any solvent used must also
18、be sufficiently resolved from any impurity, the internal standard, and the phenol peak.7. Apparatus7.1 Gas ChromatographAny chromatograph having a flame ionization detector that can be operated at the conditions givenin Table 1. The system should have sufficient sensitivity to obtain a minimum peak
19、height response for a 2 mg/kg impurity twicethe height of the signal background noise.7.2 ColumnsThe choice of column is based on resolution requirements.Any column may be used that is capable of resolvingall significant impurities from the major component. The column and conditions described in Tab
20、le 1 have been used successfullyand shall be used as referee in cases of dispute.7.3 RecorderElectronic integration is recommended.Chromatographic data systems are preferred but electronic integrationmay be used if the user can demonstrate that the results are consistent with the precision statement
21、. Recorders are not consideredadequate for meeting the precision requirements of this standard.8. Reagents8.1 Purity of ReagentReagent grade chemicals shall be used in all tests. Unless otherwise indicated, it is intended that allreagents shall conform to the specifications of the Committee on Analy
22、tical Reagents of the American Chemical Society, wheresuch specifications are available.4 Other grades may be used, provided it is first ascertained that the reagent is of sufficiently highpurity to permit its use without lessening the accuracy of the determination.8.2 High Purity Phenol(99.99 % or
23、greater purity).8.3 Carrier Gas, Makeup, and Detector GasesHelium, hydrogen, nitrogen, or other carrier, makeup and detector gases99.999 % minimum purity. Oxygen in carrier gas less than 1 ppm, less than 0.5 ppm is preferred. Purify carrier, makeup, anddetector gases to remove oxygen, water, and hyd
24、rocarbons.8.4 Compressed AirPurify air to remove water and hydrocarbons. Air for an FID should contain less than 0.1 ppm THC.4 Reagent Chemicals, American Chemical Society Specifications, American Chemical Society, Washington, DC. For suggestions on the testing of reagents not listed bythe American
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD61422016RED0248STANDARDTESTMETHODFORANALYSISOFPHENOLBYCAPILLARYGASCHROMATOGRAPHY 采用 毛细管 色谱 分析 苯酚

链接地址:http://www.mydoc123.com/p-521677.html