ASTM D6047-2017 red 1875 Standard Test Methods for Rubber Raw&x2014 Determination of 5-Ethylidenenorbornene (ENB) or Dicyclopentadiene (DCPD) in Ethylene-Propylene-Diene (EPDM) Ter.pdf
《ASTM D6047-2017 red 1875 Standard Test Methods for Rubber Raw&x2014 Determination of 5-Ethylidenenorbornene (ENB) or Dicyclopentadiene (DCPD) in Ethylene-Propylene-Diene (EPDM) Ter.pdf》由会员分享,可在线阅读,更多相关《ASTM D6047-2017 red 1875 Standard Test Methods for Rubber Raw&x2014 Determination of 5-Ethylidenenorbornene (ENB) or Dicyclopentadiene (DCPD) in Ethylene-Propylene-Diene (EPDM) Ter.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D6047 15D6047 17Standard Test Methods forRubber, RawDetermination of 5-Ethylidenenorbornene(ENB) or Dicyclopentadiene (DCPD) in Ethylene-Propylene-Diene (EPDM) Terpolymers1This standard is issued under the fixed designation D6047; the number immediately following the designation indicat
2、es the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 These test methods cover the determination of
3、 the content of 5-ethylidenenorbornene (ENB) or Dicyclopentadiene (DCPD)in ethylene-propylene-diene (EPDM) terpolymers. They are applicable to diene contents in the 0.1 to 10 mass % range.1.2 ENB and DCPD are dienes introduced in ethylene/propylene rubbers to generate specific cure properties. Since
4、 highprecision for diene content determination has become very important, a Fourier Transform Infrared Spectroscopic (FTIR) methodwas developed. Diene determination was performed in the past by a refractive index technique.NOTE 1The procedures for % ENB and % DCPD differ only in the location in the
5、infrared (IR) of the IR peak being quantified.1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibil
6、ityof the user of this standard to establish appropriate safety safety, health, and healthenvironmental practices and determine theapplicability of regulatory limitations prior to use.1.5 This international standard was developed in accordance with internationally recognized principles on standardiz
7、ationestablished in the Decision on Principles for the Development of International Standards, Guides and Recommendations issuedby the World Trade Organization Technical Barriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2D297 Test Methods for Rubber ProductsChemical Analysi
8、sD1416 Test Methods for Rubber from Synthetic SourcesChemical Analysis (Withdrawn 1996)3D3568 Test Methods for RubberEvaluation of EPDM (Ethylene Propylene Diene Terpolymers) Including Mixtures With OilD3900 Test Methods for RubberDetermination of Ethylene Units in Ethylene-Propylene Copolymers (EPM
9、) and inEthylene-Propylene-Diene Terpolymers (EPDM) by Infrared SpectrometryD4483 Practice for Evaluating Precision for Test Method Standards in the Rubber and Carbon Black Manufacturing IndustriesE168 Practices for General Techniques of Infrared Quantitative AnalysisE932 Practice for Describing and
10、 Measuring Performance of Dispersive Infrared SpectrometersE1421 Practice for Describing and Measuring Performance of Fourier Transform Mid-Infrared (FT-MIR) Spectrometers: LevelZero and Level One Tests2.2 ANCHA Document:4Specification for Evaluation of Research Quality Analysis of Infrared Spectra3
11、. Summary of Test Methods3.1 The test specimen is molded between two PTFE-coated aluminum or Mylar sheets. The ENB content is determined fromits infrared absorbance at 16811690 cm1, a measure of ENBs exocyclic double bond. The DCPD content is determined fromits infrared absorbance at 16051610 cm1, a
12、 measure of DCPDs monocyclic double bond.1 These test methods are under the jurisdiction of Committee D11 on Rubber and Rubber-like Materials and are the direct responsibility of Subcommittee D11.11 onChemical Analysis.Current edition approved Nov. 1, 2015Oct. 1, 2017. Published December 2015October
13、 2017. Originally approved in 1996. Last previous edition approved in 20142015as D6047 99 (2014).D6047 15. DOI: 10.1520/D6047-15.10.1520/D6047-17.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standards
14、volume information, refer to the standards Document Summary page on the ASTM website.3 The last approved version of this historical standard is referenced on www.astm.org.4 “Specification for Evaluation of Research Quality Analysis of Infrared Spectra,” Analytical Chemistry, ANCHA, Vol 47, No. 11, p
15、. 94a.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult pri
16、or editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States13.2 The second derivative of the absorbanc
17、e is calculated and ratioed to an internal thickness gage. For ENB the resultingsecond derivative peak near 1690 cm1 is related to ENB mass fraction by calibrating the instrument with known EPDM standards.For DCPD, the resulting second derivative peak near 1610 cm1 is related to DCPD mass fraction b
18、y calibrating the instrumentwith known EPDM standards.3.3 Two main steps are performed in this procedure: automatic determination of film thickness and quantification of diene.3.4 For oil-extended polymers, the oil must be extracted before diene is determined. Test Methods D1416, Sections 67 through
19、74 and Test Methods D297 can be used for this purpose.4. Apparatus4.1 Press, Carver-type, capable of pressing films at 150C and 10 MPa or higher.4.1.1 Primary MoldA stainless steel (SS) mold, approximately 400 m thick, with an opening sized appropriately for thespecimen film holder described in 4.4
20、(typically 2 by 2 cm). The mold should have approximately the same dimensions as the pressplatens.4.1.2 Alternate MoldA thinner mold may be used; however, precision may be adversely affected at low diene levels. Testprecision should be determined when thinner films are utilized. Example: a 127-m (0.
21、005-in) SS shim with a 15- by 35-mmopening may be used for the simultaneous determination of ethylene (Test Methods D3900) and diene.4.1.3 Alternative Mold for Low Molecular Weight (Liquid) EPDM TerpolymersFor liquid EPDM a ring washer 22 mm ODby 16 mm ID (7/8 in OD by 5/8 inch in ID) 400 m thick is
22、 used as a apacer between salt plates (NaBr, NaCl) to set a fixed pathlength. The spacer is sized to cover only the outer edge of the salt plate.4.2 Sheets for Molding, either PTFE-coated aluminum sheets or Mylar, Type A, 36 m thick or less.4.3 Specimen Film HoldersFilms may be molded, cut, and tran
23、sferred to a film holder. Magnetic film holders are ideal.Alternatively, a mold sized to fit in the spectrometer specimen compartment, with an appropriate size opening may be used tosupport the film without removal after pressing.4.4 Infrared Fourier Transform SpectrophotometerAn instrument capable
24、of measuring absorbances in the range 400 to 6000cm1 with a transmittance specification (accuracy) of 6 1 % T or better. The instrument should be capable of spectral resolutionof 2 cm1 (see “Specification for Evaluation of Research Quality Analysis of Infrared Spectra”). A deuterated triglycine sulf
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD60472017RED1875STANDARDTESTMETHODSFORRUBBERRAWX2014DETERMINATIONOF5ETHYLIDENENORBORNENEENBORDICYCLOPENTADIENEDCPDINETHYLENEPROPYLENEDIENEEPDMTERPDF

链接地址:http://www.mydoc123.com/p-521390.html