1、Designation: D5950 12Standard Test Method forPour Point of Petroleum Products (Automatic Tilt Method)1This standard is issued under the fixed designation D5950; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revis
2、ion. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.INTRODUCTIONThis test method covers an alternative procedure for the determination of pour point of petroleumproducts using an automatic app
3、aratus.1. Scope*1.1 This test method covers the determination of pour pointof petroleum products by an automatic instrument that tilts thetest jar during cooling and detects movement of the surface ofthe test specimen with an optical device.1.2 This test method is designed to cover the range oftempe
4、ratures from 66 to +51C; however, the range oftemperatures included in the 1992 interlaboratory test programonly covered the temperature range from 39 to +6C, and therange of temperatures included in the 1998 interlaboratory testprogram was 51 to 11C. (See Section 13.)1.3 Test results from this test
5、 method can be determined at1 or 3C intervals.1.4 This test method is not intended for use with crude oils.NOTE 1The applicability of this test method on residual fuel sampleshas not been verified. For further information on applicability, refer to13.4.1.5 The values stated in SI units are to be reg
6、arded asstandard. No other units of measurement are included in thisstandard.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determ
7、ine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D97 Test Method for Pour Point of Petroleum ProductsD4057 Practice for Manual Sampling of Petroleum andPetroleum ProductsD4177 Practice for Automatic Sampling of Petroleum andPetroleum ProductsD6
8、708 Practice for StatisticalAssessment and Improvementof Expected Agreement Between Two Test Methods thatPurport to Measure the Same Property of a Material2.2 Energy Institute Standard:3IP 15 Test Method for Pour Point of Petroleum Products3. Terminology3.1 Definitions:3.1.1 pour point, nin petroleu
9、m products, the lowesttemperature at which movement of the test specimen isobserved under the prescribed conditions of this test method.3.2 Definitions of Terms Specific to This Standard:3.2.1 no-flow point, nin petroleum products, the tempera-ture of the test specimen at which a wax crystal structu
10、re orviscosity increase, or both, impedes movement of the surfaceof the test specimen under the conditions of the test.3.2.1.1 DiscussionThe no-flow point occurs when, uponcooling, the formation of wax crystal structures or the viscosityincrease, or both, has progressed to the point where the applie
11、dobservation device no longer detects movement under theconditions of the test. The preceding observation temperature,at which flow of the test specimen is last observed, is the pourpoint.3.2.2 tiltingtechnique of movement where the test jar in avertical position is moved towards a horizontal positi
12、on toinduce specimen movement.3.2.2.1 DiscussionWhen the test jar is tilted and held in ahorizontal position for 5 s without detection of specimenmovement, this is the no-flow point and the test is complete.4. Summary of Test Method4.1 After preliminary heating, the test specimen is insertedinto the
13、 automatic pour point apparatus. After starting the1This test method is under the jurisdiction of ASTM Committee D02 onPetroleum Products and Lubricants and is the direct responsibility of SubcommitteeD02.07 on Flow Properties.Current edition approved April 15, 2012. Published August 2012. Originall
14、yapproved in 1996. Last previous edition approved in 2007 as D595002(2007).DOI: 10.1520/D5950-12.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Docum
15、ent Summary page onthe ASTM website.3Available from Energy Institute, 61 New Cavendish St., London, WIG 7AR,U.K., http:/www.energyinst.org.uk.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 194
16、28-2959, United States.program, the specimen is cooled according to the coolingprofile listed in Table 1 and examined at either 1 or 3Cintervals. The lowest temperature at which movement ofspecimen is detected, by the automatic equipment, is displayedas the pour point.NOTE 2If the automatic pour app
17、aratuss preheat option is utilized,place the test specimen into the apparatus. After starting the program, theapparatus will automatically carry out the preliminary heating.5. Significance and Use5.1 The pour point of a petroleum product is an index of thelowest temperature of its utility for certai
18、n applications. Flowcharacteristics, like pour point, can be critical for the correctoperation of lubricating oil systems, fuel systems, and pipelineoperations.5.2 Petroleum blending operations require precise measure-ment of the pour point.5.3 This test method can determine the pour point of the te
19、stspecimen with a resolution of 1.0C.5.4 Test results from this test method can be determined ateither 1 or 3C intervals.5.5 This test method yields a pour point in a format similarto Test Method D97/IP 15 when the 3C interval results arereported.NOTE 3Since some users may wish to report their resul
20、ts in a formatsimilar to Test Method D97 (in 3C intervals) the precisions were derivedfor the temperatures rounded to the 3C intervals. For statements on biasrelative to Test Method D97, see 13.3.5.6 This test method has better repeatability and reproduc-ibility relative to Test Method D97/IP 15 as
21、measured in the1998 interlaboratory test program. (See Section 13.)6. Apparatus6.1 Optical Automatic Pour Point Apparatus4The auto-matic pour point apparatus described in this test methodconsists of a microprocessor controller that is capable ofcontrolling one or more independent test cells. The app
22、aratusshall include provisions for independently controlling thetemperature of each cell according to the specified coolingprofile, monitoring continuously the specimen temperature,and detecting any movement of the specimen during tilting (seeFig. 1). The instrument shall be operated according to th
23、emanufacturers instructions.6.2 Temperature Probe, IEC 751 Class A: D T=6(0.15 + 0.002 |T|), capable of measurement from +70 down to80C. The temperature probe shall be in the center of the testjar and the top of the platinum tip immersed 3 mm below thesurface of the oil.6.3 Test Jar, clear cylindric
24、al glass, flat bottom, 34 60.5-mm outside diameter, 1.4 6 0.15-mm wall thickness, 1206 0.5-mm height, thickness of the bottom 2.0 6 0.5-mm,marked with a line to indicate the sample height 54 6 0.5-mmabove the inside bottom.6.4 Jacket, brass, cylindrical, flat bottom, 113 60.2-mm indepth, 45 +0, 0.1-
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD595020123125STANDARDTESTMETHODFORPOURPOINTOFPETROLEUMPRODUCTSAUTOMATICTILTMETHOD 石油 产品 标准 试验 方法

链接地址:http://www.mydoc123.com/p-521108.html