ASTM D5950-2002(2007) 923 Standard Test Method for Pour Point of Petroleum Products (Automatic Tilt Method)《石油产品的倾点(自动倾斜法)标准试验方法》.pdf
《ASTM D5950-2002(2007) 923 Standard Test Method for Pour Point of Petroleum Products (Automatic Tilt Method)《石油产品的倾点(自动倾斜法)标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D5950-2002(2007) 923 Standard Test Method for Pour Point of Petroleum Products (Automatic Tilt Method)《石油产品的倾点(自动倾斜法)标准试验方法》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 5950 02 (Reapproved 2007)An American National StandardStandard Test Method forPour Point of Petroleum Products (Automatic Tilt Method)1This standard is issued under the fixed designation D 5950; the number immediately following the designation indicates the year oforiginal adoption or
2、, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.INTRODUCTIONThis test method covers an alternative procedure for the determination of pour
3、 point of petroleumproducts using an automatic apparatus.1. Scope1.1 This test method covers the determination of pour pointof petroleum products by an automatic instrument that tilts thetest jar during cooling and detects movement of the surface ofthe test specimen with an optical device.1.2 This t
4、est method is designed to cover the range oftemperatures from 57 to +51C; however, the range oftemperatures included in the 1992 interlaboratory test programonly covered the temperature range from 39 to +6C, and therange of temperatures included in the 1998 interlaboratory testprogram was 51 to 11C.
5、 (See Section 13.)1.3 Test results from this test method can be determined at1 or 3C intervals.1.4 This test method is not intended for use with crude oils.NOTE 1The applicability of this test method on residual fuel sampleshas not been verified. For further information on applicability, refer to13.
6、4.1.5 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish ap
7、pro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D97 Test Method for Pour Point of Petroleum ProductsD 4057 Practice for Manual Sampling of Petroleum andPetroleum ProductsD 4177 Practice for Auto
8、matic Sampling of Petroleum andPetroleum Products2.2 Energy Institute Standard:3IP 15 Test Method for Pour Point of Petroleum Products3. Terminology3.1 Definitions:3.1.1 pour point, nin petroleum products, the lowesttemperature at which movement of the test specimen isobserved under the prescribed c
9、onditions of this test method.3.2 Definitions of Terms Specific to This Standard:3.2.1 no-flow point, nin petroleum products, the tempera-ture of the test specimen at which a wax crystal structure orviscosity increase, or both, impedes movement of the surfaceof the test specimen under the conditions
10、 of the test.3.2.1.1 DiscussionThe no-flow point occurs when, uponcooling, the formation of wax crystal structures or the viscosityincrease, or both, has progressed to the point where the appliedobservation device no longer detects movement under theconditions of the test. The preceding observation
11、temperature,at which flow of the test specimen is last observed, is the pourpoint.3.2.2 tiltingtechnique of movement where the test jar in avertical position is moved towards a horizontal position toinduce specimen movement.3.2.2.1 DiscussionWhen the test jar is tilted and held in ahorizontal positi
12、on for 5 s without detection of specimenmovement, this is the no-flow point and the test is complete.4. Summary of Test Method4.1 After preliminary heating, the test specimen is insertedinto the automatic pour point apparatus. After starting theprogram, the specimen is cooled according to the coolin
13、g1This test method is under the jurisdiction of ASTM Committee D02 onPetroleum Products and Lubricants and is the direct responsibility of SubcommitteeD02.07 on Flow Properties.Current edition approved Nov. 1, 2007. Published January 2008. Originallyapproved in 1996. Last previous edition approved i
14、n 2002 as D 595002.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from Energy Institute, 61 New C
15、avendish St., London, WIG 7AR,U.K., http:/www.energyinst.org.uk.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.profile listed in Table 1 and examined at either 1 or 3Cintervals. The lowest temperature at which movement ofspecimen is
16、 detected, by the automatic equipment, is displayedas the pour point.NOTE 2If the automatic pour apparatuss preheat option is utilized,place the test specimen into the apparatus. After starting the program, theapparatus will automatically carry out the preliminary heating.5. Significance and Use5.1
17、The pour point of a petroleum product is an index of thelowest temperature of its utility for certain applications. Flowcharacteristics, like pour point, can be critical for the correctoperation of lubricating oil systems, fuel systems, and pipelineoperations.5.2 Petroleum blending operations requir
18、e precise measure-ment of the pour point.5.3 This test method can determine the pour point of the testspecimen with a resolution of 1.0C.5.4 Test results from this test method can be determined ateither 1 or 3C intervals.5.5 This test method yields a pour point in a format similarto Test Method D97/
19、IP 15 when the 3C interval results arereported.NOTE 3Since some users may wish to report their results in a formatsimilar to Test Method D97(in 3C intervals) the precisions were derivedfor the temperatures rounded to the 3C intervals. For statements on biasrelative to Test Method D97, see 13.3.5.6 T
20、his test method has better repeatability and reproduc-ibility relative to Test Method D97/IP 15 as measured in the1998 interlaboratory test program. (See Section 13.)6. Apparatus6.1 Optical Automatic Pour Point Apparatus4The auto-matic pour point apparatus described in this test methodconsists of a
21、microprocessor controller that is capable ofcontrolling one or more independent test cells. The apparatusshall include provisions for independently controlling thetemperature of each cell according to the specified coolingprofile, monitoring continuously the specimen temperature,and detecting any mo
22、vement of the specimen during tilting (seeFig. 1). The instrument shall be operated according to themanufacturers instructions.6.2 Temperature Probe, IEC 751 Class A: D T=6(0.15 + 0.002 |T|), capable of measurement from +70 down to80C. The temperature probe shall be in the center of the testjar and
23、the top of the platinum tip immersed 3 mm below thesurface of the oil.6.3 Test Jar, clear cylindrical glass, flat bottom, 34 60.1-mm outside diameter, 31 6 0.3-mm inside diameter, 120 60.5-mm height, thickness of the bottom 2.4-mm maximum. Itshall be marked with a line to indicate the sample height
24、54 60.5-mm above the inside bottom.6.4 Jacket, brass, cylindrical, flat bottom, 113 60.2-mm indepth, 45 +0, 0.1-mm inside diameter. It shall be cooledaccording to the cooling profile specified.6.5 Cooling Circulating Bath, equipped with a circulatingpump and capable of maintaining a temperature at l
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD595020022007923STANDARDTESTMETHODFORPOURPOINTOFPETROLEUMPRODUCTSAUTOMATICTILTMETHOD 石油 产品 自动 倾斜

链接地址:http://www.mydoc123.com/p-521107.html