ASTM D5917-2009 752 Standard Test Method for Trace Impurities in Monocyclic Aromatic Hydrocarbons by Gas Chromatography and External Calibration《用气相色谱法和外标法对单环芳香烃中微量杂质的标准试验方法》.pdf
《ASTM D5917-2009 752 Standard Test Method for Trace Impurities in Monocyclic Aromatic Hydrocarbons by Gas Chromatography and External Calibration《用气相色谱法和外标法对单环芳香烃中微量杂质的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D5917-2009 752 Standard Test Method for Trace Impurities in Monocyclic Aromatic Hydrocarbons by Gas Chromatography and External Calibration《用气相色谱法和外标法对单环芳香烃中微量杂质的标准试验方法》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 5917 09Standard Test Method forTrace Impurities in Monocyclic Aromatic Hydrocarbons byGas Chromatography and External Calibration1This standard is issued under the fixed designation D 5917; the number immediately following the designation indicates the year oforiginal adoption or, in
2、the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method covers the determination of the totalnonaromatic hydrocarbons and
3、trace monocyclic aromatichydrocarbons in toluene, mixed xylenes, and p-xylenes by gaschromatography. The purity of toluene, mixed xylenes, orp-xylenes can also be calculated. Calibration of the gaschromatographic system is done by the external standardcalibration technique. A similar test method, us
4、ing the internalstandard calibration technique, is Test Method D 2360.1.2 Total aliphatic hydrocarbons containing 1 through 10carbon atoms (methane through decanes) can be detected bythis test method at concentrations ranging from 0.001 to 2.500weight %.1.2.1 A small amount of benzene in mixed xylen
5、es orp-xylenes may not be distinguished from the nonaromatics andthe concentrations are determined as a composite (see 6.1).1.3 Monocyclic aromatic hydrocarbon impurities containing6 through 10 carbon atoms (benzene through C10aromatics)can be detected by this test method at individual concentration
6、sranging from 0.001 to 1.000 weight %.1.4 In determining the conformance of the test results toapplicable specifications, results shall be rounded off in accor-dance with the rounding-off method of Practice E29.1.5 The values stated in SI units are to be regarded asstandard. No other units of measur
7、ement are included in thisstandard.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limit
8、ations prior to use. For specific hazardstatement, see Section 9.2. Referenced Documents2.1 ASTM Standards:2D 841 Specification for Nitration Grade TolueneD 2306 Test Method for C8Aromatic Hydrocarbon Analy-sis by Gas Chromatography3D 2360 Test Method for Trace Impurities in MonocyclicAromatic Hydro
9、carbons by Gas ChromatographyD 3437 Practice for Sampling and Handling Liquid CyclicProductsD 4052 Test Method for Density and Relative Density ofLiquids by Digital Density MeterD 4307 Practice for Preparation of Liquid Blends for Use asAnalytical StandardsD 4790 Terminology of Aromatic Hydrocarbons
10、 and Re-lated ChemicalsD 5136 Specification for High Purity p-XyleneD 5211 Specification for Xylenes for p-Xylene FeedstockD 6526 Test Method for Analysis of Toluene by CapillaryColumn Gas ChromatographyD 6809 Guide for Quality Control and Quality AssuranceProcedures for Aromatic Hydrocarbons and Re
11、lated Ma-terialsE29 Practice for Using Significant Digits in Test Data toDetermine Conformance with SpecificationsE 260 Practice for Packed Column Gas ChromatographyE 355 Practice for Gas Chromatography Terms and Rela-tionshipsE 691 Practice for Conducting an Interlaboratory Study toDetermine the Pr
12、ecision of a Test MethodE 1510 Practice for Installing Fused Silica Open TubularCapillary Columns in Gas Chromatographs2.2 Other Document:1This test method is under the jurisdiction of ASTM Committee D16 onAromatic Hydrocarbons and Related Chemicals and is the direct responsibility ofSubcommittee D1
13、6.04 on Instrumental Analysis.Current edition approved Jan. 1, 2009. Published January 2009. Originallyapproved in 1996. Last previous edition approved in 2002 as D 5917 02.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For A
14、nnual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Withdrawn. The last approved version of this historical standard is referencedon www.astm.org.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM Internation
15、al, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.OSHA Regulations, 29CFR paragraphs 1910.1000 and1910.120043. Terminology3.1 See Terminology D 4790 for definitions of terms used inthis test method.3.2 Mixed xylenes are a mixture of C8aromatics includingm-xylene
16、, o-xylene, and p-xylene. Industry convention in-cludes ethylbenzene as a mixed xylene though ethylbenzeneis not technically a xylene. Styrene is excluded.4. Summary of Test Method4.1 A repeatable volume of the specimen to be analyzed isprecisely injected into a gas chromatograph equipped with aflam
17、e ionization detector (FID). The peak area of each impurityis measured. Concentration of each impurity is determinedfrom the linear calibration curve of peak area versus concen-tration. Purity by gas chromatography (GC) is calculated bysubtracting the sum of the impurities found from 100.00.Results
18、are reported in weight percent.5. Significance and Use5.1 Determining the type and amount of hydrocarbon im-purities remaining from the manufacture of toluene, mixedxylenes, and p-xylenes used as chemical intermediates andsolvents is often required. This test method is suitable forsetting specificat
19、ions and for use as an internal quality controltool where these products are produced or are used. Typicalimpurities are: alkanes containing 1 to 10 carbons atoms,benzene, toluene, ethylbenzene (EB), xylenes, and aromatichydrocarbons containing nine carbon atoms.5.1.1 Refer to Test Method D 2306 for
20、 determining the C8aromatic hydrocarbon distribution in mixed xylenes.5.2 Purity is commonly reported by subtracting the deter-mined expected impurities from 100.00. However, a gaschromatographic analysis cannot determine absolute purity ifunknown or undetected components are contained within themat
21、erial being examined.5.3 This test method is similar to Test Method D 2360,however, interlaboratory testing has indicated a bias may existbetween the two methods. Therefore the user is cautioned thatthe two methods may not give comparable results.6. Interferences6.1 In some cases for mixed xylenes a
22、nd p-xylene, it may bedifficult to resolve benzene from the nonaromatic hydrocar-bons. Therefore the concentrations are determined as a com-posite. In the event that the benzene concentration must bedetermined, an alternate method such as Test Method D 6526must be selected to ensure an accurate asse
23、ssment of thebenzene concentration.6.2 Complete separation of ethylbenzene and m-xylenefrom p-xylene is difficult and can be considered adequate if thedistance from baseline to valley between peaks is not greaterthan 50 % of the peak height of the impurity.7. Apparatus7.1 Gas ChromatographAny instru
24、ment having a flameionization detector that can be operated at the conditions givenin Table 1. The system shall have sufficient sensitivity to obtaina minimum peak height response for 0.001 weight % impurityof twice the height of the background noise.7.2 ColumnsThe choice of column is based on resol
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD59172009752STANDARDTESTMETHODFORTRACEIMPURITIESINMONOCYCLICAROMATICHYDROCARBONSBYGASCHROMATOGRAPHYANDEXTERNALCALIBRATION

链接地址:http://www.mydoc123.com/p-521046.html