ASTM D5787-1995(2009) 459 Standard Practice for Monitoring Well Protection《井保护监控的标准实施规程》.pdf
《ASTM D5787-1995(2009) 459 Standard Practice for Monitoring Well Protection《井保护监控的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM D5787-1995(2009) 459 Standard Practice for Monitoring Well Protection《井保护监控的标准实施规程》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 5787 95 (Reapproved 2009)Standard Practice forMonitoring Well Protection1This standard is issued under the fixed designation D 5787; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number
2、 in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.INTRODUCTIONThis practice for monitoring well protection is provided to promote durable and reliable protectionof installed monitoring wells against natu
3、ral and man caused damage. The practices contained promotethe development and planning of monitoring well protection during the design and installation stage.1. Scope1.1 This practice identifies design and construction consid-erations to be applied to monitoring wells for protection fromnatural and
4、man caused damage or impacts.1.2 The installation and development of a well is a costlyand detailed activity with the goal of providing representativesamples and data throughout the design life of the well.Damages to the well at the surface frequently result in loss ofthe well or changes in the data
5、. This standard provides foraccess control so that tampering with the installation should beevident. The design and installation of appropriate surfaceprotection will mitigate the likelihood of damage or loss.1.3 This practice may be applied to other surface or subsur-face monitoring device location
6、s, such as piezometers, per-meameters, temperature or moisture monitors, or seismicdevices to provide protection.1.4 The values stated in inch-pound units are to be regardedas standard. No other units of measurement are included in thisstandard.1.5 This practice offers a set of instructions for perf
7、ormingone or more specific operations. This document cannot replaceeducation or experience and should be used in conjunctionwith professional judgment. Not all aspects of this practice maybe applicable in all circumstances. This ASTM standard is notintended to represent or replace the standard of ca
8、re by whichthe adequacy of a given professional service must be judged,nor should this document be applied without consideration ofa projects many unique aspects. The word “Standard” in thetitle of this document means only that the document has beenapproved through the ASTM consensus process.2. Refe
9、renced Documents2.1 ASTM Standards:2C 150 Specification for Portland CementC 294 Descriptive Nomenclature for Constituents of Con-crete AggregatesD 5092 Practice for Design and Installation of GroundWater Monitoring Wells3. Terminology3.1 Definitions:3.1.1 barrierany device that physically prevents
10、access ordamage to an area.3.1.2 barrier markersplastic, or metal posts, often inbright colors, placed around a monitoring well to aid inidentifying or locating the well.3.1.3 barrier postssteel pipe, typically from 4 to 12inches in diameter and normally filled with concrete or groutthat are placed
11、around a well location to protect the well fromphysical damage, such as from vehicles.3.1.4 boreholea circular open or uncased subsurface holecreated by drilling.3.1.5 casingpipe, finished in sections with either threadedconnections or bevelled edges to be field welded, which isinstalled temporarily
12、 or permanently to counteract caving, toadvance the borehole, or to isolate the zone being monitored, ora combination thereof.3.1.6 casing, protectivea section of larger diameter pipethat is emplaced over the upper end of a smaller diametermonitoring well riser or casing to provide structural protec
13、tionto the well and restrict unauthorized access into the well.1This practice is under the jurisdiction of ASTM Committee D18 on Soil andRock and is the direct responsibility of Subcommittee D18.21 on Ground Water andVadose Zone Investigations.Current edition approved April 1, 2009. Published April
14、2009. Originallyapproved in 1995. Last previous edition approved in 2000 as D 5787 95 (2000).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document
15、Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3.1.7 riserthe pipe extending from the well screen to orabove the ground surface.3.1.8 sealed capa sealable riser cap, normally gasketed orsealed, that i
16、s designed to prevent water or other substancesfrom entering into, or out of the well riser.3.1.9 vented capa cap with a small hole that is installed ontop of the riser.4. Significance and Use4.1 An adequately designed and installed surface protectionsystem will mitigate the consequences of naturall
17、y or mancaused damages which could otherwise occur and result ineither changes to the data, or complete loss of the monitoringwell.4.2 The extent of application of this practice may dependupon the importance of the monitoring data, cost of monitoringwell replacement, expected or design life of the m
18、onitoringwell, the presence or absence of potential risks, and setting orlocation of the well.4.3 Monitoring well surface protection should be a part ofthe well design process, and installation of the protectivesystem should be completed at the time of monitoring wellinstallation and development.4.4
19、 Information determined at the time of installation of theprotective system will form a baseline for future monitoringwell inspection and maintenance. Additionally, elements of theprotection system will satisfy some regulatory requirementssuch as for protection of near surface ground water and welli
20、dentification.5. Design Considerations5.1 The design of a monitoring well protective system islike other design processes, where the input considerations aredetermined and the design output seeks to remedy or mitigatethe negative possibilities, while taking advantage of the sitecharacteristics.5.2 T
21、he factors identified in this practice should be consid-ered during the design of the monitoring well protectivesystem. The final design should be included in the monitoringwell design and installation documentation and be completedand verified during the final completion and development ofthe well.
22、5.3 In determining the level or degree of protection re-quired, the costs and consequences, such as loss of data orreplacement of the well, must be weighed against the probabil-ity of occurrence and the desired life of the well. Formonitoring wells which will be used to obtain data over a shorttime
23、period, the protection system may be minimal. For wellswhich are expected to be used for an indefinite period, are in avulnerable location, and for which the costs of lost data couldbe high, the protective system should be extensive. Factors toconsider and methods of mitigating them are presented in
24、 thefollowing sections.5.3.1 Impact DamagesPhysical damages resulting fromconstruction equipment, livestock, or vehicles striking themonitoring well casing frequently occur. Protective devicesand approaches include:5.3.1.1 Extra heavy protective casings with a reinforcedconcrete apron extending seve
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD578719952009459STANDARDPRACTICEFORMONITORINGWELLPROTECTION 保护 监控 标准 实施 规程 PDF

链接地址:http://www.mydoc123.com/p-520697.html