1、A-A-5473b m 9999974 OLL9bBO 749 m A-A-54 7 3 6 23 November 1992 COMMERCIAL ITEM DESCRIPTION THERMOMETER, CLINICAL, HUMAN (Electronic, Battery Powered, With Battery Charger) The General Services Administration has authorized the use of this Commercial Item Description. This Commercial Item Descriptio
2、n covers requirements for an electronic thermometer suitable for oral or rectal body temperature measurement in humans. Salient characteristics: The thermometer shall be a portable, battery powered, Fahrenheit/Celsius electronic clinical thermometer system consisting of a thermometer, battery charge
3、r/storage base, oral probe, rectal probe, disposable probe covers, and dispenser probe cover brackets. The battery charger shall operate from 110/220V, 50/60 Hz power. The battery charger shall be in compliance with UL 544, Standard for Medical and Dental Equipment. The thermometer shall have a pred
4、ictive mode temperature range of 90.0F to 107.gF, plus or minus 0.2OF. The thermometer shall have monitor mode temperature range of 88.0F to 107.gF, plus or minus O.ZF. The thermometer shall have a pulse mode range of 20 to 200 beats per minute (BPM). Pulse mode activation shall be by depressing a b
5、utton on the bottom of the thermometer. The thermometer shall have an LED charge light indicator on the display panel when the battery is recharging. AMSC N/A FSC 6515 DISTRIBUTION STATEMENT A: Approved for public release; distribution is unlimited. Provided by IHSNot for ResaleNo reproduction or ne
6、tworking permitted without license from IHS-,-,-A-A-5 4 7 3 6 The thermometer shall have an audible tone that sounds when temperature has been computed, when pulse has been calculated, and when an error message has occurred. The thermometer shall have a display panel that indicates temperature readi
7、ngs, tissue contact, pulse rate, and error messages on a five character minimum LED display. A rechargeable nickel-cadmium battery, that automatically recharges when placed in the battery charger/storage base shall be supplied with the thermometer. The battery shall recharge in no more than 10 hours
8、. Battery life shall be at least five hours continuous from fully charged state. The thermometer shall have the capability of both Celsius and Fahrenheit readings. The thermometer shall be capable of being hung around the neck for convenience during use. The thermometer shall have a compartment for
9、holding a box of disposable probe covers. The thermometer shall include one oral probe with a spring action cord approximately 2 feet long when coiled, approximately 4 feet long when stretched. It shall be capable of attachment to and detachment from the thermometer with ease. One rectal probe with
10、a spring action cord approximately 2 feet long when coiled, approximately 4 feet long when stretched shall also be included with the thermometer. It shall be capable of attachment to and detachment from the thermometer with ease. The thermometer shall be provided with 1000 clean, disposable, rigid p
11、lastic probe covers. The covers shall be 6 inches long and shall be fitted onto and removed from each probe without having to touch the probe cover. The thermometer shall be provided with a probe cover dispenser bracket which may be metal or plastic. If metal, it shall be corrosion-resisting steel,
12、properly hardened and passivated. 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A - A-5 4 7 3 b W 9999974 0119682 511 W A-A-54 7 3 6 Wor1ririanr;liip. The electronic thermometer shall be free from defects which detract from its appearance or impa
13、ir its serviceability. Unit. Each (EA). Oiie electronic thermometer, as specified, constitutes one unit. Quality Assurance Provisions. Responsibility for inspection. Unless otherwise specifiec in the contract or purchase order, the contractor is responsible for the performance of all inspection requ
14、irements as specified herein. Except as otherwise specified in the contract or purchase order, the contractor may use his own or any facilities suitable for the performance of the inspection requirements specified herein, unless disapproved by the Government. The Government reserves the right to per
15、form any of the inspections set forth in the specification where such inspections are deemed necessary to assure supplies and services conform to prescribed requirements. Records. Records of examinations and tests perfcrmed by or for the contractor shall be maintained by the contractor and made avai
16、lable to the Government upon the Governments request, at any time, or from time to time, during the performance of the contract and for a period of three years after delivery of the supplies to which such records relate. Inspection. Inspection, as used herein, is defined as both examination (such as
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DODAA547361992THERMOMETERCLINICALHUMANELECTRONICBATTERYPOWEREDWITHBATTERYCHARGER 人类 临床 温度计 PDF

链接地址:http://www.mydoc123.com/p-701766.html