1、A-A-5474b 65 9999974 0087703 73T D I INCH-POUND I A-A-54 7 4 6 25 September 1992 COMMERCIAL ITEM DESCRIPTION STOPCOCK, INTRAVENOUS THERAPY, 3-WAY, PLASTIC The General Services Administration has authorized the use of this Commercial Item Description as a replacement for Military Specification MIL-S-
2、37434 which is cancelled. This Commercial Item Description covers a sterile, disposable, stopcock with three separate fluid paths and attached tubing. Salient characteristics: Material. fabricated from a rigid or semi-rigid plastic. The rotating spigot shall be of a color contrasting to the stopcock
3、 body. The stopcock and male Luer connector shall be The plastic tubing shall be fabricated from transparent, pliant plastic. Tubing shall be flexible, but shall be rigid enough to prevent collapse during normal use. The plastic shall be inert to blood and common IV fluids and meet the requirements
4、of the USP for Class II plastics. The total combined quantity of barium, cadmium, and lead for each component (excluding end protectors) shall not exceed 5 parts per million (ppm). Style. desian. and dimensions. The stopcock set shall be of the styles shown in accordance with Figure 1: Style 1: w/20
5、 inch extension tubing Style 2: w/33 inch extension tubing AMSC N/A FSC 6515 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-5474b 65 = 9999974 0087704 b7b A-A-54 7
6、 4 6 The set shall consist of a stopcock with a rotating spigot and a secured length of tubing to the stopcock body. Luer connector (needle adapter) shall be secured to the distal end of the tubing. assembled to the rotating spigot. enable piercing and immediate resealing characteristics when punctu
7、red with needles of 18 gage or smaller. The stopcock proper shall have two side ports, 180 apart, each having internal female Luer tapers. The cavity of the rotating spigot that contains the rubber injection site shall also possess a female Luer taper. Luer fittings shall be in accordance with IS0 S
8、tandard 594 and may be female Luer Lock. The rubber plug of the injection site shall be attached by means of a retainer which allows for removal of the injection site. Once removed, the rubber plug shall not be reattached. The rotating spigot shall have an arrow-type handle to indicate which female
9、side Luer port will be part of the fluid path. A male The injection site shall be The injection site shall The two stopcock open ports and male Luer connector shall be covered with readily removable plastic protectors. protectors shall maintain cleanliness and freedom from particle infiltration and
10、shall maintain sterility of the fluid paths until manually removed. The end Performance. The stopcock set shall be a unit suitable for use in administering the direction of flow of blood and solutions for simultaneous and/or alternate intravenous therapy. Stopcocks shall be tested for freedom from l
11、eakage, clear passage of fluid, and security of assembly. Storase. The stopcock set shall be tested to ensure freedom from tackiness, brittleness, or other evidence of deterioration when stored in an elevated temperature. Sterility. with USP or AAMI guidelines. shall be .000001. The stopcock set sha
12、ll be sterile in accordance Sterility Assurance Level Instructions for use. A detailed instruction sheet for proper use of the stopcocks shall be provided with each individual stopcock or with each unit package. Workmanshin. free from parting lines. any defects which affect its appearance or utility
13、. The Luer tapers and rotating spigot shall be The stopcock shall be free from 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-54746 65 = 9999974 0087705 502 A-A-5 4 7 4 6 Unit. Package (PG). One package containing fifty individually packaged s
14、terile stopcocks, with instructions, as specified, constitutes one unit. The individual package shall be a sealed, peel-open type container capable of maintaining sterility of contents unless the package is damaged or opened. QUALITY ASSURANCE PROVISIONS. Responsibility for inspection. Unless otherw
15、ise specified in the contract or purchase order, the contractor is responsible for the performance of all inspection requirements as specified herein. Except otherwise specified in the contract or purchase order, the contractor may use his own or any facilities suitable for the performance of the in
16、spection requirements specified herein, unless disapproved by the Government. The Government reserves the right to perform any of the inspections set forth in the specification where such inspections are deemed necessary to assure supplies and services conform to prescribed requirements. for the con
17、tractor shall be maintained by the contractor and made available to the Government upon request, at any time during the performance of the contract and for a period of three years after delivery of the supplies to which such records relate. Inspection. Inspection, as used herein, is defined as both
18、examination (such as visual or auditory investigation without the use of special laboratory appliances or procedures) and testing (determination by technical means of physical and chemical properties) of the item. I Records. Records of examinations and tests performed by or t Tests. Tests shall be c
19、onducted to determine compliance with specification requirements. Where feasible, the same sample shall be used for the determination of two or more test characteristics. Samplina for tests. accordance with MIL-STD-105, with an inspection level of S-4. Unit of product for test purposes shall be one
20、set. failure shall be cause for rejection. Sampling for tests shall be conducted in A test 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-5474b 65 m 9999974 0087706 449 m A-A-5474 6 Clear passase of fluid. The stopcock set shall be tested with
21、 an appropriate testing fluid applied internally to the stopcock body with the stopcock body placed in a horizontal position. Each fluid path as shown in Figure 2 shall be tested, in turn, using testing assembly fixtures in accordance with IS0 Standard 594 except that the male connector shall not be
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DODAA547461992STOPCOCKINTRAVENOUSTHERAPY3WAYPLASTIC 塑料 方式 静脉 治疗 活塞 PDF

链接地址:http://www.mydoc123.com/p-701767.html