ASTM D5613-1994(2008) 374 Standard Test Method for Open-Channel Measurement of Time of Travel Using Dye Tracers《使用染料示踪剂明渠测量行程时间标准试验方法》.pdf
《ASTM D5613-1994(2008) 374 Standard Test Method for Open-Channel Measurement of Time of Travel Using Dye Tracers《使用染料示踪剂明渠测量行程时间标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D5613-1994(2008) 374 Standard Test Method for Open-Channel Measurement of Time of Travel Using Dye Tracers《使用染料示踪剂明渠测量行程时间标准试验方法》.pdf(20页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 5613 94 (Reapproved 2008)Standard Test Method forOpen-Channel Measurement of Time of Travel Using DyeTracers1This standard is issued under the fixed designation D 5613; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision,
2、 the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers a means of measuring thetime-of-travel of water and waterborne solutes by the use
3、 ofdye tracers and tracing techniques. This test method is similarto methods developed by the U.S. Geological Survey anddescribed in other referenced documents.1.2 This test method describes the dye tracers, measuringequipment used, and field and laboratory procedures custom-arily used.1.3 This test
4、 method describes the methods of tracer studyanalysis and data presentation.1.4 The user of this test method should address the follow-ing concerns regarding the use of tracers in water bodies:1.4.1 Determine whether the chemical has clearance orapproval or has potential or preceived impacts relatin
5、g topotable, industrial, irrigation, or fish and wildlife use.1.4.2 Determine whether approvals are required by involvedagencies.1.4.3 Document contacts regarding notification.1.5 The values stated in inch-pound units except for chemi-cal concentrations and liquid volumes for step dilutions, whichar
6、e stated in SI units, are to be regarded as the standard.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bili
7、ty of regulatory limitations prior to use. For specific hazardsstatements, see Section 9.2. Referenced Documents2.1 ASTM Standards:2D 1192 Guide for Equipment for Sampling Water andSteam in Closed Conduits3D 2777 Practice for Determination of Precision and Bias ofApplicable Test Methods of Committee
8、 D19 on WaterD 3370 Practices for Sampling Water from Closed ConduitsD 3858 Test Method for Open-Channel Flow Measurementof Water by Velocity-Area MethodD 4411 Guide for Sampling Fluvial Sediment in Motion2.2 ISO Standard:4ISO 555/2-1974 Liquid Flow Measurement in OpenChannelsDilution Methods for Me
9、asurement of SteadyFlow, Part 2: Integration (Sudden Injection) Method.3. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 automatic programmable samplera portable devicedesigned to collect sequential, discrete water samples repre-sentative of the water mixture moving in the river
10、 in thevicinity of the sampler at a single point in a cross section.Depending on the make and model of the device, watersamples can be collected at equal or variable time intervals.3.1.2 centroidthe center of mass of the dye responsecurve calculated as outlined by Parker and Hunt (1)5.3.1.3 depth-in
11、tegrated samplea water sample collected insuch a manner as to be representative of the water mixturemoving in the river in the vicinity of the sampler at a singlevertical in a cross section.3.1.4 dispersionthe three-dimensional process of dissemi-nating the dye within a rivers waters.3.1.5 flow dura
12、tionthe percentage of time during which aspecific discharge is equalled or exceeded.3.1.6 fluorometeran instrument that measures the lumi-nescence of a fluorescent substance when subjected to a lightsource of a given wave length.3.1.7 injection sitea study site where the tracer is to beintroduced in
13、to a parcel of river water. This study site is usually1This test method is under the jurisdiction of ASTM Committee D19 on Waterand is the direct responsibility of Subcommittee D19.07 on Sediments, Geomor-phology, and Open-Channel Flow.Current edition approved Oct. 1, 2008. Published November 2008.
14、Originallyapproved in 1994. Last previous edition approved in 2003 as D 5613 94 (2003).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summar
15、y page onthe ASTM website.3Withdrawn. The last approved version of this historical standard is referencedon www.astm.org.4Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.org.5The boldface numbers in parentheses refer to the li
16、st of references at the end ofthis test method.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.a sufficient distance upstream of the study reach such thatcomplete vertical and lateral mixing of the tracer in a parcel ofriver water ha
17、s occurred before the water parcels entry into thestudy reach.3.1.8 lateral dispersionthe process of disseminating thedye within a river waters horizontal axis perpendicular to itslongitudinal axis. The completion of this process is dependenton the width of the river and velocity variations.3.1.9 le
18、ading edgethe first detectable dye concentrationobserved at a sampling site.3.1.10 longitudinal dispersionthe process of disseminat-ing the dye within a rivers waters along its upstream-downstream axis. This component of the dispersion processcontinues downstream indefinitely.3.1.11 mixingthe blendi
19、ng of two or more substances intoone uniform mass.3.1.12 peakthe maximum dye concentration observed at asampling site.3.1.13 point samplea water sample collected in such amanner as to be representative of the water mixture moving inthe river in the vicinity of the sampler at a single point in across
20、 section.3.1.14 sample sitea study site where water samples arecollected for determination of the tracer-concentration re-sponse curve.3.1.15 standard integrated depth samplera device de-signed to accumulate a water sample from a stream vertical atsuch a rate that the velocity in the nozzle at the p
21、oint of intakeis always as nearly as possible identical with the immediatestream velocity.3.1.16 study reachthe section of a rivers length that is tobe studied.3.1.17 study sitesections of a river where data are to bedetermined, monitored, measured, and where tracer is to beintroduced into the river
22、.3.1.18 tracer response curveat each sampling site, theplots of tracer concentration versus time after the tracerinjection.3.1.19 trailing edgethe point of the falling limb of the dyeresponse curve that is equal to approximately 2 % of the peakconcentration observed at a sampling site.3.1.20 vertica
23、l dispersionthe process of disseminating thedye within a rivers waters vertical axis perpendicular to itsupstream-downstream axis. This dispersion process is usuallycompleted first.4. Summary of Test Method4.1 Dye tracers injected into a stream are assumed to behavein the same manner as the water mo
24、lecules themselves. Ameasure of the longitudinal movement of a tracer along a givenstreamline will be a measure of the movement of an element offluid in the stream and of its dispersion characteristics for thatstreamline.4.2 The initial planning of a dye tracer time-of-travel studyinvolves the estim
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD561319942008374STANDARDTESTMETHODFOROPENCHANNELMEASUREMENTOFTIMEOFTRAVELUSINGDYETRACERS 使用 染料 示踪剂

链接地址:http://www.mydoc123.com/p-520250.html